Development of 1000 V Impulse Voltage Standard Measuring System

Author(s):  
Tianyu Xia ◽  
Zhaozhi Long ◽  
Wenting Li ◽  
Jiawei Fan
2012 ◽  
Vol 180 (2) ◽  
pp. 24-32 ◽  
Author(s):  
Satoru Miyazaki ◽  
Hisashi Goshima ◽  
Takaaki Amano ◽  
Hiroyuki Shinkai ◽  
Masafumi Yashima ◽  
...  

2011 ◽  
Vol 131 (5) ◽  
pp. 455-462 ◽  
Author(s):  
Satoru Miyazaki ◽  
Hisashi Goshima ◽  
Takaaki Amano ◽  
Hiroyuki Shinkai ◽  
Masafumi Yashima ◽  
...  

2017 ◽  
Vol 66 (6) ◽  
pp. 1433-1440 ◽  
Author(s):  
Enrico Mohns ◽  
Gunter Roeissle ◽  
Soeren Fricke ◽  
Florian Pauling

Author(s):  
Prof. Dharmesh Kumar

In gift things, social distancing is that the most vital reality. Moreover, the very fact is COVID-19 patient's initial symptom is vital sign is high. the explanation why, measure body temperature is most vital, however has to maintain social distancing. Whereas ancient thermometers can’t confirm of social distancing, wherever our developed contactless measuring system are able to do temperature on show by victimisation Arduino uno because the main management device also as MLX90615 because the infrared (IR) measuring system device. As a result, compared with the standard measuring system, it shows robust points like convenient reading, wide selection of temperature activity, and accuracy wherever temperature output is displayed digitally. Besides, it might be used all over attributable to its easy-handling


Mechanik ◽  
2018 ◽  
Vol 91 (10) ◽  
pp. 822-824
Author(s):  
Ryszard Wolny

In analysis of accuracy of 5-axis CNC milling machine measuring system with telescopic kinematic ball bar was used. Standard measuring test was made. The modified test was proposed with application of investigated inclined basis. The obtained results were compared. The accuracy of machine tool in indirect way was evaluated.


2014 ◽  
Vol 986-987 ◽  
pp. 1661-1665
Author(s):  
Zhao Zhi Long ◽  
Fei Lu ◽  
Wen Ting Li

The uncertainty contribution related to linearity shall be considered in the calculation of measurement uncertainty when using the impulse voltage measuring system. Under the condition that the national standard is not yet established at present, the paper proposed an experimental method to measure the linearity of 600kV damped capacitive impulse divider (HCR600). The paper used low voltage resistance divider R200S to measure the linearity of generator, and obtained the linearity curve. With the increase of charging voltage, the linearity of divider can be obtained by measuring the charging voltage of impulse voltage generator precisely and its ratio of indicating value of the sample divider HCR600 after corrected. The result shows that the linearity of HCR600 decreases from +0.4% to-0.8%; the maximum difference between positive polarity and negative polarity is 0.14% and the linearity of negative polarity is superior to that of positive polarity. Besides, the paper used a 500kV resistance divider (SMR 7.7/ref500) calibrated by PTB to compare with HCR600, and obtained the linearity curve. By comparison, two curves show a good agreement, the maximum difference between them is 0.15% at the same voltage. The result shows that the method proposed in the paper can be used to measure the linearity of divider accurately. It also can be used as experimental verification in the process of the national standard establishing and to calibrate the ultrahigh voltage impulse voltage measuring equipments when equipments satisfy some requirements.


Sign in / Sign up

Export Citation Format

Share Document