Development of automatic, continuous partial discharge monitoring systems to detect motor and generator partial discharges

Author(s):  
G.C. Stone ◽  
B.A. Lloyd ◽  
S.R. Campbell ◽  
H.G. Sedding
2021 ◽  
Vol 17 (2) ◽  
pp. 155014772199928
Author(s):  
Jiajia Song ◽  
Jinbo Zhang ◽  
Xinnan Fan

Partial discharges are the major cause of deterioration in the insulation characteristics of switchgears. Therefore, timely detection of partial discharge in switchgear and potential insulation faults is an urgent problem that needs to be addressed in the power supervision industry. In this study, a device was proposed for online monitoring of high-voltage switchgears based on pulse current method and ozone (O3) detection. The pulse current method obtains the PD signal by monitoring the phase holes on the switch indicator. Occurrence of a partial discharge in a certain phase leads to the production of a discharge pulse, which can be coupled out by a capacitive sensor. The current spectrum and the O3 produced by partial discharge were processed via fast Fourier transform for accurate diagnosis of the occurrence of partial discharge and its severity in switchgears. The proposed method allows for convenient acquisition of the partial discharge signal, simple installation of the device, and realization with inexpensive sensors.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3267
Author(s):  
Ramon C. F. Araújo ◽  
Rodrigo M. S. de Oliveira ◽  
Fernando S. Brasil ◽  
Fabrício J. B. Barros

In this paper, a novel image denoising algorithm and novel input features are proposed. The algorithm is applied to phase-resolved partial discharge (PRPD) diagrams with a single dominant partial discharge (PD) source, preparing them for automatic artificial-intelligence-based classification. It was designed to mitigate several sources of distortions often observed in PRPDs obtained from fully operational hydroelectric generators. The capabilities of the denoising algorithm are the automatic removal of sparse noise and the suppression of non-dominant discharges, including those due to crosstalk. The input features are functions of PD distributions along amplitude and phase, which are calculated in a novel way to mitigate random effects inherent to PD measurements. The impact of the proposed contributions was statistically evaluated and compared to classification performance obtained using formerly published approaches. Higher recognition rates and reduced variances were obtained using the proposed methods, statistically outperforming autonomous classification techniques seen in earlier works. The values of the algorithm’s internal parameters are also validated by comparing the recognition performance obtained with different parameter combinations. All typical PD sources described in hydro-generators PD standards are considered and can be automatically detected.


Author(s):  
Nikolay Ignatev ◽  
◽  
Sergey Tetiora ◽  
Dmitry Turkin ◽  
◽  
...  

A model of the partial discharges in a sample of solid insulation with air cavity is presented. The material of the insulation is cross-linked polyethylene. The model is based on an active-capacitive equivalent circuit, in which the resistance of the air cavity at the instant of a partial discharge ignition is shunted by the active resistance of the spark. The model takes into consideration the delay of the discharge development. The evaluation of the diagnostic value of the apparent and true charges is carried out. The results of the apparent and true charges relationship with the dimensions and proportions of the air cavity are presented. It is shown that the same magnitude of both true and apparent charges can correspond to the different volumes and shapes of the air cavities in the insulation.


Sign in / Sign up

Export Citation Format

Share Document