Direct oil cooling of traction motors in hybrid drives

Author(s):  
Zhe Huang ◽  
Shafigh Nategh ◽  
Viktor Lassila ◽  
Mats Alakula ◽  
Jinliang Yuan
Keyword(s):  
Machines ◽  
2021 ◽  
Vol 9 (6) ◽  
pp. 124
Author(s):  
Dantam Rao ◽  
Madhan Bagianathan

Currently, permanent-magnet-type traction motors drive most electric vehicles. However, the potential demagnetization of magnets in these motors limits the performance of an electric vehicle. It is well known that during severe duty, the magnets are demagnetized if they operate beyond a ‘knee point’ in the B(H) curve. We show herein that the classic knee point definition can degrade a magnet by up to 4 grades. To prevent consequent excessive loss in performance, this paper defines the knee point k as the point of intersection of the B(H) curve and a parallel line that limits the reduction in its residual flux density to 1%. We show that operating above such a knee point will not be demagnetizing the magnets. It will also prevent a magnet from degenerating to a lower grade. The flux density at such a knee point, termed demag flux density, characterizes the onset of demagnetization. It rightly reflects the value of a magnet, so can be used as a basis to price the magnets. Including such knee points in the purchase specifications also helps avoid the penalty of getting the performance of a low-grade magnet out of a high-grade magnet. It also facilitates an accurate demagnetization analysis of traction motors in the worst-case conditions.


Electronics ◽  
2020 ◽  
Vol 9 (7) ◽  
pp. 1063 ◽  
Author(s):  
Christoph Datlinger ◽  
Mario Hirz

Rotor shaft position sensors are required to ensure the efficient and reliable control of Permanent Magnet Synchronous Machines (PMSM), which are often applied as traction motors in electrified automotive powertrains. In general, various sensor principles are available, e.g., resolvers and inductive- or magnetoresistive sensors. Each technology is characterized by strengths and weaknesses in terms of measurement accuracy, space demands, disturbing factors and costs, etc. Since the most frequently applied technology, the resolver, shows some weaknesses and is relatively costly, alternative technologies have been introduced during the past years. This paper investigates state-of-the-art position sensor technologies and compares their potentials for use in PMSM in automotive powertrain systems. The corresponding evaluation criteria are defined according to the typical requirements of automotive electric powertrains, and include the provided sensor accuracy under the influence of mechanical tolerances and deviations, integration size, and different electrical- and signal processing-related parameters. The study presents a mapping of the potentials of different rotor position sensor technologies with the target to support the selection of suitable sensor technologies for specified powertrain control applications, addressing both system design and components development.


1988 ◽  
Vol 17 (sup1) ◽  
pp. 113-116
Author(s):  
Takehiko Fujioka ◽  
Masakazu Iguchi ◽  
Takahiro Ito

2021 ◽  
Vol 18 (1) ◽  
pp. 80-94
Author(s):  
D. I. Prokhor ◽  
◽  
N. V. Grachev ◽  

Objective: An equivalent mode of accelerated thermal aging of the insulation system of electrical ma- chines is described to confirm the resource corresponding to a given period and operating conditions. Methods: The equivalent mode of accelerated heat aging was determined based on the Montzinger rule and tested in the course of research and development work (R&D) on the development, manufacture and implementation of a set of bench and operational tests of the insulation system of an increased heat resistance class of a diesel locomotive traction motor. Results: The relevance of R&D has been revealed, as a result of which the implementation of the idea was required, based on the statement about the re- duction of the insulation resource of electrical machines when the permissible heating is exceeded by 8–12 °С to various types of insulating materials. The advantages of the method presented in the article in relation to traditional solutions of this problem are demonstrated, and also improved consumer proper- ties of the traction electric motor of a diesel locomotive with a replaced insulation system of an increased class of heat resistance are presented. Generally, experimental tests and preliminary operational data are an acceptable basis for thermal evaluation of electrical insulating materials. However, it is important to remember that the scientific criterion is met and not to use the results of different types of tests in the analysis. Based on the world experience in diagnostics of additional insulation parameters for monitoring the state of insulation parameters, the possibility of using the “Doctor” series insulation monitoring de- vices has been determined and practically confirmed. Together with the results of subsequent operational tests, during which the insulation was also monitored using these mobile devices, it is argued that after carrying out the relevant research work, thanks to the mobile devices of the “Doctor” series, it is pos- sible to carry out predictive analytics of the failure of traction motors (TED) in any operating conditions. The functional value is determined and applied in practice. The “H” class insulation system developed by the specialists of JSC “VNIKTI” is mainly based on insulating materials produced by JSC “Holding Company „Elinar“”; the compound “Elplast 180ID” (JSC “Electroizolit”) or its analogue “Elkom-180” JSC “Holding company „Elinar“”), for anchor coils and equalizers, a wound PPIPK-2 wire in polyimide- fluoroplastic insulation (GC “Moskabelmet”) is used. Practical importance: It is stated that all stages of manufacturing and testing, determined at the initial stage of R&D, confirmed the results of the deve- lopment stages (overhaul (manufacture) of prototypes of TED using a new isolation system according to the design documentation of JSC “VNIKTI”). Bench tests have confirmed typical characteristics, speci- fied resource and insulation characteristics with equivalent accelerated thermal aging corresponding to an electric motor’s service life of 20 years in ordinary operation on a diesel locomotive, residual life of elements of the insulation system of naturally cut armature segments, main and auxiliary poles coils. In the specialized laboratory of JSC “Holding Company „Elinar“”, an experimental TED diesel locomotive set with the investigated insulation system was manufactured and installed on two sections of the main- line diesel locomotive 2TE116. Operational tests of an experimental TED diesel locomotive set under operating conditions were successful.


Sign in / Sign up

Export Citation Format

Share Document