Robust networked control of load frequency in multi-area interconnected power system

Author(s):  
Hamid Zamanian ◽  
Jafar Ghaisari ◽  
Farid Sheikholeslam

Load frequency control (LFC) in interconnected power system of small distribution generation (DG) for reliability in distribution system. The main objective is to performance evaluation load frequency control of hybrid for interconnected two-area power systems. The simulation consist of solar farm 10 MW and gasifier plant 300 kW two-area in tie line. This impact LFC can be address as a problem on how to effectively utilize the total tie-line power flow at small DG. To performance evaluation and improve that defect of LFC, the power flow of two-areas LFC system have been carefully studied, such that, the power flow and power stability is partially LFC of small DG of hybrid for interconnected two-areas power systems. Namely, the controller and structural properties of the multi-areas LFC system are similar to the properties of hybrid for interconnected two-area LFC system. Inspired by the above properties, the controller that is propose to design some proportional-integral-derivative (PID) control laws for the two-areas LFC system successfully works out the aforementioned problem. The power system of renewable of solar farm and gasifier plant in interconnected distribution power system of area in tie – line have simulation parameter by PID controller. Simulation results showed that 3 types of the controller have deviation frequency about 0.025 Hz when tie-line load changed 1 MW and large disturbance respectively. From interconnected power system the steady state time respond is 5.2 seconds for non-controller system, 4.3 seconds for automatic voltage regulator (AVR) and 1.4 seconds for under controlled system at 0.01 per unit (p.u.) with PID controller. Therefore, the PID control has the better efficiency non-controller 28 % and AVR 15 %. The result of simulation in research to be interconnected distribution power system substation of area in tie - line control for little generate storage for grid connected at better efficiency and optimization of renewable for hybrid. It can be conclude that this study can use for applying to the distribution power system to increase efficiency and power system stability of area in tie – line.


2008 ◽  
Vol 8 (20) ◽  
pp. 3676-3682 ◽  
Author(s):  
K. Sabahi ◽  
A. Sharifi ◽  
M. Aliyari Sh ◽  
M. Teshnehlab ◽  
M. Aliasghary

2019 ◽  
Vol 41 (14) ◽  
pp. 4084-4099 ◽  
Author(s):  
Deepesh Sharma ◽  
Naresh Kumar Yadav

In an interconnected multi-area power system, Load Frequency Control (LFC) is a main challenging problem. This paper presents the Fractional Order Proportional Integral (FOPI) controller for an interconnected two-area power system, wherein each area has multi-source power systems. The gains of the proposed controller are being optimized by Lion Algorithm (LA), utilizing an integral square error (ISE) criterion, to develop the proposed Lion with Levy Update-based FOPI controller (LLUFOPI). The proposed LA schedules the gain of the LLUFOPI controller by achieving the least possible error. Hence, the LLUFOPI controller assures better LFC in the two-area interconnected power system. The performance of the proposed controller is assessed by considering the practical constraints in power system such as Generation Rate Constraints (GRC), communication delay, AC/DC link, step load variation and Capacitive Energy Storage (CES) device. Finally, the simulation results show that the LLUFOPI controller provides a well- optimized gain that is 89% higher than the other algorithms with better stability. The Integral Square Error (ISE) value of the proposed controller is 81.1% lesser than the other algorithms. Better LFC in the two-area multi-source-interconnected power system is hence achieved with minimum ISE.


Sign in / Sign up

Export Citation Format

Share Document