Sub-millimeter Spatial Resolution Terahertz Computed Tomography System based on Differential Pulse Delay Method

Author(s):  
Bo-Yi Wu ◽  
Shang-Hua Yang
2019 ◽  
Vol 9 (3) ◽  
pp. 374 ◽  
Author(s):  
Mohsin Zafar ◽  
Karl Kratkiewicz ◽  
Rayyan Manwar ◽  
Mohammad Avanaki

A low-cost Photoacoustic Computed Tomography (PACT) system consisting of 16 single-element transducers has been developed. Our design proposes a fast rotating mechanism of 360o rotation around the imaging target, generating comparable images to those produced by large-number-element (e.g., 512, 1024, etc.) ring-array PACT systems. The 2D images with a temporal resolution of 1.5 s and a spatial resolution of 240 µm were achieved. The performance of the proposed system was evaluated by imaging complex phantom. The purpose of the proposed development is to provide researchers a low-cost alternative 2D photoacoustic computed tomography system with comparable resolution to the current high performance expensive ring-array PACT systems.


2010 ◽  
Vol 26 (1) ◽  
pp. 69-69
Author(s):  
Hiroshi Watanabe ◽  
T. Wagatsuma ◽  
Y. Nomura ◽  
E. Honda ◽  
T. Kurabayashi

2009 ◽  
Vol 26 (1) ◽  
pp. 56-60 ◽  
Author(s):  
Hiroshi Watanabe ◽  
T. Wagatsuma ◽  
Y. Nomura ◽  
E. Honda ◽  
T. Kurabayashi

2015 ◽  
Author(s):  
Z. Yu ◽  
S. Leng ◽  
S. M. Jorgensen ◽  
Z. Li ◽  
R. Gutjahr ◽  
...  

2021 ◽  
Vol 20 ◽  
pp. 153303382110101
Author(s):  
Thet-Thet Lwin ◽  
Akio Yoneyama ◽  
Hiroko Maruyama ◽  
Tohoru Takeda

Phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer provides high sensitivity and high spatial resolution, and it has the ability to depict the fine morphological structures of biological soft tissues, including tumors. In this study, we quantitatively compared phase-contrast synchrotron-based X-ray computed tomography images and images of histopathological hematoxylin-eosin-stained sections of spontaneously occurring rat testicular tumors that contained different types of cells. The absolute densities measured on the phase-contrast synchrotron-based X-ray computed tomography images correlated well with the densities of the nuclear chromatin in the histological images, thereby demonstrating the ability of phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer to reliably identify the characteristics of cancer cells within solid soft tissue tumors. In addition, 3-dimensional synchrotron-based phase-contrast X-ray computed tomography enables screening for different structures within tumors, such as solid, cystic, and fibrous tissues, and blood clots, from any direction and with a spatial resolution down to 26 μm. Thus, phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer shows potential for being useful in preclinical cancer research by providing the ability to depict the characteristics of tumor cells and by offering 3-dimensional information capabilities.


2010 ◽  
Author(s):  
Eiichi Sato ◽  
Ablajan Abduraxit ◽  
Toshiyuki Enomoto ◽  
Manabu Watanabe ◽  
Keitaro Hitomi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document