Accuracy of Position and Pose Estimates of Ultrasound Probe Relative to Bony Anatomy

Author(s):  
Luke J MacLean ◽  
Antony J Hodgson
POCUS Journal ◽  
2016 ◽  
Vol 1 (3) ◽  
pp. 13-14
Author(s):  
Stuart Douglas, PGY4 ◽  
Joseph Newbigging, MD ◽  
David Robertson, MD

FAST Background: Focused Assessment with Sonography for Trauma (FAST) is an integral adjunct to primary survey in trauma patients (1-4) and is incorporated into Advanced Trauma Life Support (ATLS) algorithms (4). A collection of four discrete ultrasound probe examinations (pericardial sac, hepatorenal fossa (Morison’s pouch), splenorenal fossa, and pelvis/pouch of Douglas), it has been shown to be highly sensitive for detection of as little as 100cm3 of intraabdominal fluid (4,5), with a sensitivity quoted between 60-98%, specificity of 84-98%, and negative predictive value of 97-99% (3).


2018 ◽  
Author(s):  
G Toporek ◽  
◽  
H Wang ◽  
M Balicki ◽  
H Xie
Keyword(s):  

Author(s):  
Tomohito Hasegawa ◽  
Norimichi Kawashima ◽  
Shinichi Takeuchi ◽  
Mutsuo Ishikawa ◽  
Minoru Kuribayashi Kurosawa

Author(s):  
Hiroki Sato ◽  
Takahiro Kato ◽  
Tomoaki Motoyanagi ◽  
Kimihiro Takemasa ◽  
Yuki Narita ◽  
...  

Abstract In recent years, a novel technique has been employed to maintain a distance between the prostate and the rectum by transperineally injecting a hydrogel spacer (HS). However, the effect of HS on the prostate positional displacement is poorly understood, despite its stability with HS in place. In this study, we investigated the effect of HS insertion on the interfraction prostate motion during the course of proton therapy (PT) for Japanese prostate cancer patients. The study population consisted of 22 cases of intermediate-risk prostate cancer with 11 cases with HS insertion and 11 cases without HS insertion. The irradiation position and preparation were similar for both groups. To test for reproducibility, regular confirmation computed tomography (RCCT) was done four times during the treatment period, and five times overall [including treatment planning CT (TPCT)] in each patient. Considering the prostate position of the TPCT as the reference, the change in the center of gravity of the prostate relative to the bony anatomy in the RCCTs of each patient was determined in the left–right (LR), superior–inferior (SI) and anterior–posterior (AP) directions. As a result, no significant difference was observed across the groups in the LR and SI directions. Conversely, a significant difference was observed in the AP direction (P < 0.05). The proportion of the 3D vector length ≤5 mm was 95% in the inserted group, but 55% in the non-inserted group. Therefore, HS is not only effective in reducing rectal dose, but may also contribute to the positional reproducibility of the prostate.


2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Mohammed Obaid ◽  
Qianwei Zhang ◽  
Scott J. Adams ◽  
Reza Fotouhi ◽  
Haron Obaid

Abstract Background Telesonography systems have been developed to overcome barriers to accessing diagnostic ultrasound for patients in rural and remote communities. However, most previous telesonography systems have been designed for performing only abdominal and obstetrical exams. In this paper, we describe the development and assessment of a musculoskeletal (MSK) telesonography system. Methods We developed a 4-degrees-of-freedom (DOF) robot to manipulate an ultrasound probe. The robot was remotely controlled by a radiologist operating a joystick at the master site. The telesonography system was used to scan participants’ forearms, and all participants were conventionally scanned for comparison. Participants and radiologists were surveyed regarding their experience. Images from both scanning methods were independently assessed by an MSK radiologist. Results All ten ultrasound exams were successfully performed using our developed MSK telesonography system, with no significant delay in movement. The duration (mean ± standard deviation) of telerobotic and conventional exams was 4.6 ± 0.9 and 1.4 ± 0.5 min, respectively (p = 0.039). An MSK radiologist rated quality of real-time ultrasound images transmitted over an internet connection as “very good” for all telesonography exams, and participants rated communication with the radiologist as “very good” or “good” for all exams. Visualisation of anatomic structures was similar between telerobotic and conventional methods, with no statistically significant differences. Conclusions The MSK telesonography system developed in this study is feasible for performing soft tissue ultrasound exams. The advancement of this system may allow MSK ultrasound exams to be performed over long distances, increasing access to ultrasound for patients in rural and remote communities.


Author(s):  
Douwe M. van Willigen ◽  
Eunchul Kang ◽  
Jovana Janjic ◽  
Emile Noothout ◽  
Zu-Yao Chang ◽  
...  

2001 ◽  
Vol 101 (6) ◽  
pp. 629-635 ◽  
Author(s):  
Sagar N. DOSHI ◽  
Katerina K. NAKA ◽  
Nicola PAYNE ◽  
Christopher J.H. JONES ◽  
Moira ASHTON ◽  
...  

Flow-mediated dilatation (FMD) of the brachial artery assessed by high-resolution ultrasound is widely used to measure endothelial function. However, the technique is not standardized, with different groups using occlusion of either the wrist or the upper arm to induce increased blood flow. The validity of the test as a marker of endothelial function rests on the assumption that the dilatation observed is endothelium-dependent and mediated by nitric oxide (NO). We sought to compare the NO component of brachial artery dilatation observed following wrist or upper arm occlusion. Dilatation was assessed before and during intra-arterial infusion of the NO synthase inhibitor NG-monomethyl-l-arginine (l-NMMA) following occlusion of (i) the wrist (distal to ultrasound probe) and (ii) the upper arm (proximal to ultrasound probe) for 5min in ten healthy males. Dilatation was significantly greater after upper arm occlusion (upper arm, 11.62±3.17%; wrist, 7.25±2.49%; P = 0.003). During l-NMMA infusion, dilatation after wrist occlusion was abolished (from 7.25±2.49% to 0.16±2.24%; P < 0.001), whereas dilatation after upper arm occlusion was only partially attenuated (from 11.62±3.17% to 7.51±2.34%; P = 0.006). The peak flow stimulus was similar after wrist and upper arm occlusion. We conclude that dilatation following upper arm occlusion is greater than that observed after wrist occlusion, despite a similar peak flow stimulus. l-NMMA infusion revealed that FMD following wrist occlusion is mediated exclusively by NO, while dilatation following upper arm occlusion comprises a substantial component not mediated by NO, most probably related to tissue ischaemia around the brachial artery. FMD following wrist occlusion may be a more valid marker of endothelial function than dilatation following upper arm occlusion.


1999 ◽  
Vol 76 (1-3) ◽  
pp. 197-202 ◽  
Author(s):  
K.A. Roome ◽  
P.A. Payne ◽  
R.J. Dewhurst