Time synchronization based on linear regression in low cost WSNs: A performance analysis

Author(s):  
Domenico Capriglione ◽  
Deborah Casinelli ◽  
Eleonora D'Orazio ◽  
Luigi Ferrigno
Measurement ◽  
2016 ◽  
Vol 77 ◽  
pp. 105-116 ◽  
Author(s):  
Domenico Capriglione ◽  
Deborah Casinelli ◽  
Luigi Ferrigno

2014 ◽  
Vol 687-691 ◽  
pp. 4024-4028
Author(s):  
Si Hao Wang ◽  
Yong Li ◽  
Shen Ke Zhang

A reconfigurable wideband Log-Periodic Dipole Array (LPDA) is here in introduced. Built utilizing low cost it can cover frequencies from 0.2GHz to 2GHz, through the discrete adjustment of its elements. The gain of antenna in a given frequency band of operation can also be changed by the reconfiguration of its elements. The design, construction and testing processes are discussed and a performance analysis is made based on computer simulations. In this paper simulation software HFSS is used to get the optimization design of LPDA, and the simulation results are agree with the experimental dates appropriately.


Author(s):  
Esra Musbah Mohammed Musbah ◽  
Khalid Hamed Bilal ◽  
Amin Babiker A. Nabi Mustafa

VoIP stands for voice over internet protocol. It is one of the most widely used technologies. It enables users to send and transmit media over IP network. The transition from IPv4 to IPv6 provides many benefits for internet IPv6 is more efficient than IPv4. This paper presents a performance analysis of VoIP over WLAN using IPv4 and IPv6 and OPNET software program to simulate the protocols and to investigate the QoS parameters such as jitter, delay variation, packet send, and packet received and throughputs for IP4 and IP6 and compare between them.


Sensors ◽  
2021 ◽  
Vol 21 (1) ◽  
pp. 256
Author(s):  
Pengfei Han ◽  
Han Mei ◽  
Di Liu ◽  
Ning Zeng ◽  
Xiao Tang ◽  
...  

Pollutant gases, such as CO, NO2, O3, and SO2 affect human health, and low-cost sensors are an important complement to regulatory-grade instruments in pollutant monitoring. Previous studies focused on one or several species, while comprehensive assessments of multiple sensors remain limited. We conducted a 12-month field evaluation of four Alphasense sensors in Beijing and used single linear regression (SLR), multiple linear regression (MLR), random forest regressor (RFR), and neural network (long short-term memory (LSTM)) methods to calibrate and validate the measurements with nearby reference measurements from national monitoring stations. For performances, CO > O3 > NO2 > SO2 for the coefficient of determination (R2) and root mean square error (RMSE). The MLR did not increase the R2 after considering the temperature and relative humidity influences compared with the SLR (with R2 remaining at approximately 0.6 for O3 and 0.4 for NO2). However, the RFR and LSTM models significantly increased the O3, NO2, and SO2 performances, with the R2 increasing from 0.3–0.5 to >0.7 for O3 and NO2, and the RMSE decreasing from 20.4 to 13.2 ppb for NO2. For the SLR, there were relatively larger biases, while the LSTMs maintained a close mean relative bias of approximately zero (e.g., <5% for O3 and NO2), indicating that these sensors combined with the LSTMs are suitable for hot spot detection. We highlight that the performance of LSTM is better than that of random forest and linear methods. This study assessed four electrochemical air quality sensors and different calibration models, and the methodology and results can benefit assessments of other low-cost sensors.


Sign in / Sign up

Export Citation Format

Share Document