In Vivo Measurements of Cranial Electrical Stimulation Using Stereotactic-EEG: A Pilot Study

Author(s):  
Minmin Wang ◽  
Shenghua Zhu ◽  
Haonan Guan ◽  
Hongjie Jiang ◽  
Jianmin Zhang ◽  
...  
2021 ◽  
Author(s):  
Minmin Wang ◽  
Jiawei Han ◽  
Hongjie Jiang ◽  
Junming Zhu ◽  
Wuwei Feng ◽  
...  

Background: Multichannel transcranial electrical stimulation (tES) modeling and optimization have been widely studied in recent years. Its theoretical bases include quasi-static assumption and linear superposition. However, there is still a lack of direct in vivo evidence to validate the simulation model and theoretical assumptions. Methods: We directly measured the multichannel tES-induced voltage changes with implanted stereotactic-electroencephalographic (sEEG) electrodes in 12 epilepsy subjects. By combining these measured data, we investigate the linear superposition and prediction accuracy of simulation models for multi-electrode stimulation and further compare the induced EF differences between transcranial direct current stimulation (tDCS) and transcranial alternating current stimulation (tACS). Results: Our in vivo measurements demonstrated that the multi-electrode tES-induced voltages were almost equal to the sum of the voltages generated independently by bipolar stimulation. Both measured voltages and electric fields obtained in vivo were highly correlated with the predicted values in our cohort (Voltages: r = 0.92, p < 0.001; electric fields: r = 0.74, p < 0.001). Under the same stimulation intensity, the tDCS-induced peak-zero voltages were highly correlated with the values of tACS (r = 0.99, p < 0.001; s = 0.99). Conclusions: The in vivo measurements provides confirmatory results for linear superposition and quasi-static assumption within the human brain. Furthermore, we found that the individualized simulation model reliably predicted the multi-electrode tES-induced electric fields.


1986 ◽  
Author(s):  
A.V. Robinson ◽  
D.R. Fisher ◽  
W.D. Reece ◽  
J.A. MacLellan

2020 ◽  
Vol 6 (3) ◽  
pp. 268-271
Author(s):  
Michael Reiß ◽  
Ady Naber ◽  
Werner Nahm

AbstractTransit times of a bolus through an organ can provide valuable information for researchers, technicians and clinicians. Therefore, an indicator is injected and the temporal propagation is monitored at two distinct locations. The transit time extracted from two indicator dilution curves can be used to calculate for example blood flow and thus provide the surgeon with important diagnostic information. However, the performance of methods to determine the transit time Δt cannot be assessed quantitatively due to the lack of a sufficient and trustworthy ground truth derived from in vivo measurements. Therefore, we propose a method to obtain an in silico generated dataset of differently subsampled indicator dilution curves with a ground truth of the transit time. This method allows variations on shape, sampling rate and noise while being accurate and easily configurable. COMSOL Multiphysics is used to simulate a laminar flow through a pipe containing blood analogue. The indicator is modelled as a rectangular function of concentration in a segment of the pipe. Afterwards, a flow is applied and the rectangular function will be diluted. Shape varying dilution curves are obtained by discrete-time measurement of the average dye concentration over different cross-sectional areas of the pipe. One dataset is obtained by duplicating one curve followed by subsampling, delaying and applying noise. Multiple indicator dilution curves were simulated, which are qualitatively matching in vivo measurements. The curves temporal resolution, delay and noise level can be chosen according to the requirements of the field of research. Various datasets, each containing two corresponding dilution curves with an existing ground truth transit time, are now available. With additional knowledge or assumptions regarding the detection-specific transfer function, realistic signal characteristics can be simulated. The accuracy of methods for the assessment of Δt can now be quantitatively compared and their sensitivity to noise evaluated.


Nutrients ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 1429
Author(s):  
Theo Wallimann ◽  
Caroline H. T. Hall ◽  
Sean P. Colgan ◽  
Louise E. Glover

Based on theoretical considerations, experimental data with cells in vitro, animal studies in vivo, as well as a single case pilot study with one colitis patient, a consolidated hypothesis can be put forward, stating that “oral supplementation with creatine monohydrate (Cr), a pleiotropic cellular energy precursor, is likely to be effective in inducing a favorable response and/or remission in patients with inflammatory bowel diseases (IBD), like ulcerative colitis and/or Crohn’s disease”. A current pilot clinical trial that incorporates the use of oral Cr at a dose of 2 × 7 g per day, over an initial period of 2 months in conjunction with ongoing therapies (NCT02463305) will be informative for the proposed larger, more long-term Cr supplementation study of 2 × 3–5 g of Cr per day for a time of 3–6 months. This strategy should be insightful to the potential for Cr in reducing or alleviating the symptoms of IBD. Supplementation with chemically pure Cr, a natural nutritional supplement, is well tolerated not only by healthy subjects, but also by patients with diverse neuromuscular diseases. If the outcome of such a clinical pilot study with Cr as monotherapy or in conjunction with metformin were positive, oral Cr supplementation could then be used in the future as potentially useful adjuvant therapeutic intervention for patients with IBD, preferably together with standard medication used for treating patients with chronic ulcerative colitis and/or Crohn’s disease.


Author(s):  
Diego Guerra-Rodríguez ◽  
Liliana Rozo ◽  
Daniel Basilio ◽  
Juan Guerrero-Henriquez
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document