A modified single phase inverter topology with active common mode voltage cancellation

Author(s):  
A. Rao ◽  
T.A. Lipo ◽  
A.L. Julian
Electronics ◽  
2019 ◽  
Vol 8 (11) ◽  
pp. 1296 ◽  
Author(s):  
Li ◽  
Wang ◽  
San ◽  
Guo

For the grid-connected photovoltaic inverters, the switching-frequency common-mode voltage brings the leakage current, which should be eliminated. So far, many kinds of single-phase inverters have been published for this purpose, but most of them are the conventional voltage-type ones, which have the disadvantages of poor reliability due to the DC-link electrolytic capacitor and the risk of short-through of the bridge switches. To solve this technical issue, a novel current source inverter with AC-side clamping is proposed to mitigate the switching-frequency common-mode voltage. Meanwhile, a novel modulation method is proposed for the new single-phase inverter to achieve low-frequency operation of the main switches, which reduces the switching losses. Finally, the proposed method is implemented on the TMS320F28335DSP + XC6SLX9FPGA digital hardware platform. Also, the performance comparisons are done with the traditional solution. The results prove the proposed solution.


2021 ◽  
Vol 23 (2) ◽  
pp. 123-130
Author(s):  
Baoge Zhang ◽  
Deyu Hong

An improved single-phase unisolated grid-connected photovoltaic inverter topology is proposed to solve the common mode leakage current problem of unisolated grid-connected photovoltaic inverters. By analyzing the topology structure and voltage clamping principle of the improved inverter, the topology can maintain the same low input voltage as the full-bridge inverter, and ensure that the common-mode voltage in the continuation mode is clamped to the midpoint voltage of the bus, so as to effectively reduce the common-mode leakage current caused by the common-mode voltage suspension in the continuation mode. Moreover, the common-mode leakage current of the improved topology is smaller than that of the traditional H6-2D topology at similar conversion efficiency. The simulation results on MATLAB /Simulink platform show that the topology is feasible and effective.


Author(s):  
M. N. H. Khan ◽  
K. J. Ahmad ◽  
S. Khan ◽  
M. Hasanuzzaman

<p>The Photovoltaic (PV) is a part and parcel and well known for cost-effective and easy to operatefeatures when it is used with transformer-less inverter-based grid-tied distribution generation systems. It reduces the leakage current issue that actually occurs making paths from PV penal to ground. In this paper has been addressed this issue as main problem for reducing leakage current. Moreover, here iscompared the proposed topology’s results to AC and DC-based transformer-less topologies. The possibilities of larger number of leakage current paths indicatepower loss, which is the focus of work in this paper for different switching conditions. The results on leakage current paths using PSpice with different parasitic capacitance values from inverters of different topologies are compared with the simulation results of the topology proposed in this paper.</p>