A novel technique for optimising harmonics and reactive power with load balancing under nonsinusoidal supply and unbalanced load conditions

Author(s):  
Sincy George ◽  
Vivek Agarwal
2013 ◽  
Vol 2013 ◽  
pp. 1-11 ◽  
Author(s):  
Qiuye Sun ◽  
Jianguo Zhou ◽  
Xinrui Liu ◽  
Jun Yang

A novel compensator topology is proposed for three-phase unbalanced loads in the distribution networks. The negative and zero sequence compensation networks are proposed using delta-connected and star-connected capacitor banks. The compensation networks are paralleled with the unbalanced load to achieve a perfect balancing of active power and a complete compensation of reactive power of the unbalanced load. Intelligent grouping compound switches are implemented to control the capacitors, where, therefore, each capacitor can be switched between phases or phase and ground. Wireless sensors are also applied to acquire the load quantities. The compensation method proposed is based on symmetrical component theory. In addition, the load compensation based on instantaneous symmetrical component theory with positive sequence online extraction is proposed under unbalanced and distorted source voltages. The proposed load-balancing method and device are applied to Liaoning, Neimenggu, and Jilin provinces. The application results are provided to validate the performance of the proposed compensator topology and compensation method.


Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1951
Author(s):  
Mihaela Popescu ◽  
Alexandru Bitoleanu ◽  
Mihaita Linca ◽  
Constantin Vlad Suru

This paper presents the use of a three-phase four-wire shunt active power filter to improve the power quality in the Department of Industrial Electronics of a large enterprise from Romania. The specificity is given by the predominant existence of single-phase consumers (such as personal computers, printers, lighting and AC equipment). In order to identify the power quality indicators and ways to improve them, an A-class analyzer was used to record the electrical quantities and energy parameters in the point of common coupling (PCC) with the nonlinear loads for 27 h. The analysis shows that, in order to improve the power quality in PCC, three goals must be achieved: the compensation of the distortion power, the compensation of the reactive power and the compensation of the load unbalance. By using the conceived three-leg shunt active power filter, controlled through the indirect current control method in an original variant, the power quality at the supply side is very much improved. In the proposed control algorithm, the prescribed active current is obtained as a sum of the loss current provided by the DC voltage and the equivalent active current of the unbalanced load. The performance associated with each objective of the compensation is presented and analyzed. The results show that all the power quality indicators meet the specific standards and regulations and prove the validity of the proposed solution.


Author(s):  
Mikhail A. Sherkunkov ◽  
Stepan G. Tiguntsev

This article explores the method of joint suppression of harmonic currents, balancing currents and partial compensation of the reactive power of a non-linear asymmetric load connected in a triangle using a device installed on the low voltage side of a power transformer