A Model to Understand Current Consumption, Maximum Operating Frequency and Scaling Trends of MCML Frequency Dividers

Author(s):  
R. Nonis ◽  
E. Palumbo ◽  
P. Palestri ◽  
L. Selmi
2011 ◽  
Vol 131 (10) ◽  
pp. 1184-1192
Author(s):  
Piyasawat Navaratana Na Ayudhya ◽  
Sumate Naetiladdanon ◽  
Anawach Sangswang

Author(s):  
A. Muklas

Optimization in brown field developments is always challenging in terms of cost. One of it is XY Field, Rimau Block, South Sumatera with more than 70% of artificial lift is Electrical Submersible Pump (ESP). At ESP wells that are already running at maximum operating frequency of 60 Hz, some are still having problems to optimize their potential. The option to replace the pump with a higher rate is less of an option due to high cost. This leaves an opportunity to gain oil production by increasing frequency above 60 Hz. Upon discussion with the ESP Principal on the risks and possibilities, a trial was then planned for 3-wells. Candidates are selected from the list of ESP wells with the following criteria such as already operated at 60 Hz, still have sufficient fluid submergence, and based on simulated motor load at 70 Hz is still at safe motor load level. Frequency was increased gradually while continuously monitoring ESP Parameters (motor load, voltage and harmonic). It is also necessary to monitor the cable temperature as it is directly affected by the frequency changes. For each frequency increment, a well test is also performed to monitor the production changes. The trial was done on 3-wells (XY-364, XY-370 and XY-378), with the following promising results. XY-364 and XY-378 successfully reached the targeted 70Hz, while XY-370 stopped at 65Hz due to a cable temperature issue. Oil gain from this optimization was 48 BOPD with 1,043 BLPD and similar BS&W profile. ESP operation still normal until present day with all parameters at acceptable range. There were, however, challenges found during the trial. Cable temperature of XY-364 increased at junction box and found cable scun loosen. The problem was solved by replacing the cables. For XY-370, found temperature increment at moulded case circuit breaker during trial at 65 Hz. It was decided to hold at existing frequency. Unbalanced motor load at XY-364 and broken capacitor at XY-370 occurred at Harmonic Filter. The problem was solved by replacing the capacitor. The trial proves that we can operate ESP higher than base frequency (60 Hz) and resulted in decent oil gain. This opens an opportunity in ESP optimization above 60 Hz at an even larger scale.


Author(s):  
I. Österreicher ◽  
S. Eckl ◽  
B. Tippelt ◽  
S. Döring ◽  
R. Prang ◽  
...  

Abstract Depending on the field of application the ICs have to meet requirements that differ strongly from product to product, although they may be manufactured with similar technologies. In this paper a study of a failure mode is presented that occurs on chips which have passed all functional tests. Small differences in current consumption depending on the state of an applied pattern (delta Iddq measurement) are analyzed, although these differences are clearly within the usual specs. The challenge to apply the existing failure analysis techniques to these new fail modes is explained. The complete analysis flow from electrical test and Global Failure Localization to visualization is shown. The failure is localized by means of photon emission microscopy, further analyzed by Atomic Force Probing, and then visualized by SEM and TEM imaging.


2014 ◽  
Vol 1 (1) ◽  
Author(s):  
Colby Doyle ◽  
Matthew Gaudet ◽  
Dominic Lay ◽  
Amber McLeod ◽  
Robert Schaeffer

The primary goal of this research is to identify and examine the components of responsible drinking advertisements. We will examine industry and government related advertisements as we try to understand one of our major questions: does the source influence the validity of the message? The next group of major questions that we will be looking to answer is how are the vague quantifiers used in responsible drinking campaigns interpreted by the public?  How many drinks do people consider “too much?” What does “drink responsibly” really mean? The third major question is whether or not an individual’s current consumption patterns of alcohol have any effect on how individuals assess responsible drinking campaigns. Our qualitative research has indicated that social influences can be strongly related with drinking patterns; this will be further examined in our quantitative research. Also, we will be looking into some of the psychology behind industry and government sponsored advertisements as well as gathering and interpreting information from a sample of our target demographic. Our target demographic consists of both male and females between the ages 18-24. Our literature review and qualitative analysis gave us good insight into some of the potential answers to our questions. We will use these potential answers from our previous research to guide us as we attempt to conduct conclusive research based on a sample data of 169 individuals. Our findings will aid us in developing conclusions and recommendations for Alberta Health Services.


1949 ◽  
Author(s):  
G. K. Jensen ◽  
F. E. Wyman
Keyword(s):  

2015 ◽  
Vol 8 (1) ◽  
pp. 206-210 ◽  
Author(s):  
Yu Junyang ◽  
Hu Zhigang ◽  
Han Yuanyuan

Current consumption of cloud computing has attracted more and more attention of scholars. The research on Hadoop as a cloud platform and its energy consumption has also received considerable attention from scholars. This paper presents a method to measure the energy consumption of jobs that run on Hadoop, and this method is used to measure the effectiveness of the implementation of periodic tasks on the platform of Hadoop. Combining with the current mainstream of energy estimate formula to conduct further analysis, this paper has reached a conclusion as how to reduce energy consumption of Hadoop by adjusting the split size or using appropriate size of workers (servers). Finally, experiments show the effectiveness of these methods as being energy-saving strategies and verify the feasibility of the methods for the measurement of periodic tasks at the same time.


Sign in / Sign up

Export Citation Format

Share Document