Role of Catheter Contact Force on Biophysical Properties of the Ablation Lesion Formation in Radiofrequency Catheter Cardiac Ablation

Author(s):  
Kriengsak Masnok ◽  
Nobuo Watanabe
PLoS ONE ◽  
2021 ◽  
Vol 16 (9) ◽  
pp. e0257050
Author(s):  
Nándor Szegedi ◽  
Zoltán Salló ◽  
Péter Perge ◽  
Katalin Piros ◽  
Vivien Klaudia Nagy ◽  
...  

Introduction Our pilot study aimed to evaluate the role of local impedance drop in lesion formation during pulmonary vein isolation with a novel contact force sensing ablation catheter that records local impedance as well and to find a local impedance cut-off value that predicts successful lesion formation. Materials and methods After completing point-by-point radiofrequency pulmonary vein isolation, the success of the applications was evaluated by pacing along the ablation line at 10 mA, 2 ms pulse width. Lesions were considered successful if loss of local capture was achieved. Results Out of 645 applications, 561 were successful and 84 were unsuccessful. Compared to the unsuccessful ablation points, the successful applications were shorter (p = 0.0429) and had a larger local impedance drop (p<0.0001). There was no difference between successful and unsuccessful applications in terms of mean contact force (p = 0.8571), force-time integral (p = 0.0699) and contact force range (p = 0.0519). The optimal cut-point for the local impedance drop indicating successful lesion formation was 21.80 Ohms on the anterior wall [AUC = 0.80 (0.75–0.86), p<0.0001], and 18.30 Ohms on the posterior wall [AUC = 0.77 (0.72–0.83), p<0.0001]. A local impedance drop larger than 21.80 Ohms on the anterior wall and 18.30 Ohms on the posterior wall was associated with an increased probability of effective lesion creation [OR = 11.21, 95%CI 4.22–29.81, p<0.0001; and OR = 7.91, 95%CI 3.77–16.57, p<0.0001, respectively]. Conclusion The measurement of the local impedance may predict optimal lesion formation. A local impedance drop > 21.80 Ohms on the anterior wall and > 18.30 Ohms on the posterior wall significantly increases the probability of creating a successful lesion.


2017 ◽  
Vol 20 (9) ◽  
pp. A869
Author(s):  
R Khanna ◽  
I Kalsekar ◽  
A Barnow ◽  
R Liao

2014 ◽  
Vol 3 (1) ◽  
pp. 44-47 ◽  
Author(s):  
Tina Lin ◽  
Feifan Ouyang ◽  
Karl-Heinz Kuck ◽  
Roland Tilz

Catheter ablation has become an important modality in the treatment of most cardiac arrhythmias. In recent years there has been significant development of new ablation energies and technologies in an attempt to improve clinical outcomes and decrease disease burden. Ablation failure is often associated with inadequate lesion formation, and catheter-to-myocardial contact force (CF) and catheter stability are two of the parameters required to produce effective lesions during radiofrequency energy application. Recently, CF sensing catheters and tagging modules have been developed to give operators realtime data on catheter force and stability. This review describes the novel ThermoCool® SmartTouch® Catheter (Biosense Webster Inc., CA, US) and VisiTag™ Module (Biosense Webster Inc., CA, US) software, and discusses the results of several studies on CF and catheter stability during mapping and ablation of the left atrium and ventricle from our electrophysiology laboratory. We assess the short- and longer-term outcomes during mapping and ablation with and without CF data, as well as the use of the VisiTag Module™ software, which allows the evaluation of multiple parameters of lesion formation, then integrates and displays this as automatic tags in a relatively objective way.


2003 ◽  
Vol 133 (3) ◽  
pp. 1122-1134 ◽  
Author(s):  
Stefania Pasqualini ◽  
Claudia Piccioni ◽  
Lara Reale ◽  
Luisa Ederli ◽  
Guido Della Torre ◽  
...  

2021 ◽  
Vol 154 (9) ◽  
pp. 095101
Author(s):  
Katie A. Wilson ◽  
Stephen J. Fairweather ◽  
Hugo I. MacDermott-Opeskin ◽  
Lily Wang ◽  
Richard A. Morris ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Di Cori ◽  
L Segreti ◽  
G Zucchelli ◽  
S Viani ◽  
F Tarasco ◽  
...  

Abstract Background Contact force catheter ablation is the gold standard for treatment of atrial fibrillation (AF). Local tissue impedance (LI) evaluation has been recently studied to evaluate lesion formation during radiofrequency ablation. Purpose Aim of the study was to assess the outcomes of an irrigated catether with LI alghorithm compared to contact force (CF)-sensing catheters in the treatment of symptomatic AF. Methods A prospective, single-center, nonrandomized study was conducted, to compare outcomes between CF-AF ablation (Group 1) and LI-AF ablation (Group 2). For Group 1 ablation was performed using the Carto 3© System with the SmartTouch SF catheter and, as ablation target, an ablation index value of 500 anterior and 400 posterior. For Group 2, ablation was performed using the Rhythmia™ System with novel ablation catheter with a dedicated algorithm (DirectSense) used to measure LI at the distal electrode of this catheter. An absolute impedance drop greater than 20Ω was used at each targeted. According to the Close Protocol, ablation included a point by point pulmonary vein isolation (PVI) with an Inter-lesion space ≤5 mm in both Groups. Procedural endpoint was PVI, with confirmed bidirectional block. Results A total of 116 patients were enrolled, 59 patients in Group 1 (CF) and 57 in Group 2 (LI), 65 (63%) with a paroxismal AF and 36 (37%) with a persistent AF. Baseline patients features were not different between groups (P=ns). LI-Group showed a comparable procedural time (180±89 vs 180±56, P=0.59) but with a longer fluoroscopy time (20±12 vs 13±9 min, P=0.002). Wide antral isolation was more often observed in CF-Group (95% vs 80%, P=0.022), while LI-Group 2 required frequently additional right or left carina ablation (28% vs 14%, P=0.013). The mean LI was 106±14Ω prior to ablation and 92.5±11Ω after ablation (mean LI drop of 13.5±8Ω) during a median RF time of 26 [19–34] sec for each ablation spot. No steam pops or complications during the procedures were reported. The acute procedural success was 100%, with all PVs successfully isolated in all study patients. Regarding safety, only minor vascular complications were observed (5%), without differences between groups (p=0.97). During follow up, 9-month freedom from atrial fibrillation/atrial flutter/atrial tachycardia recurrence was 86% in Group 1 and 75% in Group 2 (P=0.2). Conclusions An LI-guided PV ablation strategy seems to be safe and effective, with acute and mid-term outcomes comparable to the current contact force strategy. LI monitoring could be a promising complementary parameter to evaluate not only wall contact but also lesion formation during power delivery. Procedural Outcomes Funding Acknowledgement Type of funding source: None


Circulation ◽  
2014 ◽  
Vol 130 (suppl_2) ◽  
Author(s):  
Zifan Pei ◽  
Andy Hudmon ◽  
Theodore R Cummins

Cardiac sodium channel (Nav1.5) is responsible for the generation and propagation of the cardiac action potential, which underlies cardiac excitability. It can be modified by a variety of post-translational modifications. Palmitoylation is one of the most common post-translational lipid modifications that can dynamically regulate protein life cycle and functional activity. In our study, we identified palmitoylation on Nav1.5 and its alteration in channel biophysical properties. Nav1.5 palmitoylation was identified in both HEK 293 cells stably expressing Nav1.5 and cardiac tissues using acyl-biotin exchange assay. Nav1.5 palmitoylation was inhibited by pre-incubating the cells with the inhibitor 2-Br-Palmitate (2BP, 25uM, 24hrs). Biophysically, 2BP treatment drastically shifted the channel steady-state inactivation to more hyperpolarized voltages, suggesting palmitoylation altering channel functional activity. In addition, four predicted endogenous palmitoylation sites were identified using CSS-Palm 3.0. Site-directed mutagenesis method was used to generate a cysteine removing background of wt Nav1.5 to study the role of predicted sites. Patch clamp analysis of wt and cysteine-removed Nav1.5 revealed a significant change in channel biophysics. 2BP treatment significantly shifted steady-state inactivation of wt Nav1.5 while not affecting cysteine-removed Nav1.5 significantly, indicating the important role of these four cysteine sites in modulating channel palmitoylation. Moreover, several LQT disease mutations were identified to potentially add or remove palmitoylation sites. Further analysis of these disease mutations revealed a significant shift in channel steady-state inactivation and this alteration cannot be seen with the substitution of other residues on the same site, suggesting the specific role of cysteine residue in causing the functional alteration. For the LQT mutation that removes potential palmitoylation site, 2BP treatment did not affect channel biophysical properties, indicating the essential role of this cysteine in channel palmitoylation. These results suggest that palmitoylation on Nav1.5 regulates channel functional activity and its modulation may contribute to new cardiac channelopathies.