Multiphase Resonant Inverter With Coupled Coils for AC–AC Induction Heating Application

2020 ◽  
Vol 56 (1) ◽  
pp. 551-560 ◽  
Author(s):  
Ruan Carlos Marques Gomes ◽  
Montie Alves Vitorino ◽  
Diego Alberto Acevedo-Bueno ◽  
Mauricio Beltrao de Rossiter Correa
Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4545
Author(s):  
Yongseung Oh ◽  
Jaeeul Yeon ◽  
Jayoon Kang ◽  
Ilya Galkin ◽  
Wonsoek Oh ◽  
...  

Single-ended (SE) resonant inverters are widely used as power converters for high-pressure rice cooker induction, with 1200 V insulated-gate bipolar transistors (IGBTs) being used as switching devices for kW-class products. When voltage fluctuations occur at the input stage of an SE resonant inverter, the resonant voltage applied to the IGBT can be directly affected, potentially exceeding the breakdown voltage of the IGBT, resulting in its failure. Consequently, the resonant voltage should be limited to below a safety threshold—hardware resonant voltage limiting methods are generally used to do so. This paper proposes a sensorless resonant voltage control method that limits the increase in the resonant voltage caused by overvoltage or supply voltage fluctuations. By calculating and predicting the resonance voltage through the analysis of the resonance circuit, the resonance voltage is controlled not to exceed the breakdown voltage of the IGBT. The experimental results of a 1.35 kW SE resonant inverter for a high-pressure induction heating rice cooker were used to verify the validity of the proposed sensorless resonant voltage limiting method.


2011 ◽  
Vol 58 (7) ◽  
pp. 2915-2925 ◽  
Author(s):  
Saichol Chudjuarjeen ◽  
Anawach Sangswang ◽  
Chayant Koompai

Author(s):  
M. Saravanan ◽  
A. Ramesh Babu

Induction heating application uses uniquely high frequency series resonant inverter for achieving high conversion efficiency. The proposed work focus on improving the practical constraints in requiring the cooling arrangements necessary for switching devices used in resonant inverter due to higher switching and conduction losses. By introducing high frequency Multi- MOSFET based series resonant inverter for the application of induction heating with the following merits such as minimum switching and conduction losses using low voltage grade  of automotive MOSFET’s and higher conversion efficiency with high frequency operation. By adding series combination of low voltage ratedMulti MOSFET switches, temperature variation according to the on-state resistance issues can be avoided by sharing the voltage across the switches depends on number switches connected in the bridge circuit without comprising existing system performance parameter such as THD, power factor, output power. Simulation results also presents to verify that the proposed system achieve higher converter efficiency.


Sign in / Sign up

Export Citation Format

Share Document