Circulating Current Analysis and the Improved D–Σ Digital Control Strategy for Multiparalleled Three-Level T-Type Grid-Connected Inverters

2020 ◽  
Vol 67 (4) ◽  
pp. 2810-2821 ◽  
Author(s):  
Biying Ren ◽  
Xiangdong Sun ◽  
Majing Yu ◽  
Jiang Liu ◽  
Qi Zhang
Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 529
Author(s):  
Cristian Verdugo ◽  
Jose Ignacio Candela ◽  
Pedro Rodriguez

Series connections of modules in cascaded multilevel converters are prone to power imbalances due to voltage differences on their DC side. When modules are connected to direct current (DC) sources, such as photovoltaic panels, the capability of withstanding power imbalances is crucial for generating the maximum power. In order to provide a possible solution for this requirement, this paper proposes a control strategy called Quadrature Voltage Compensation, which allows a wide range of power imbalances. The proposed control strategy regulates the power by introducing a circulating current between the arms and a phase angle in the output voltage. The impact of the circulating current and its effect on the phase voltage are studied. To highlight the features of the proposed strategy, an analytical model based on vector superposition is also described, demonstrating the strong capability of tolerating power differences. Finally, to validate the effectiveness of the Quadrature Voltage Compensation, simulation and experimental results are presented for a three-phase isolated multi-modular converter.


2017 ◽  
Vol 6 (6) ◽  
pp. 449-455
Author(s):  
Masafumi Fujita ◽  
Takaaki Hirose ◽  
Takashi Ueda ◽  
Hiroyuki Ishizuka ◽  
Masashi Okubo ◽  
...  

Electronics ◽  
2020 ◽  
Vol 9 (12) ◽  
pp. 2154
Author(s):  
María R. Rogina ◽  
Alberto Rodríguez ◽  
Aitor Vázquez ◽  
Diego G. Lamar ◽  
Marta M. Hernando

This paper is focused on the design of a control approach, based on the detection of events and changing between two different conduction modes, to reach high efficiency over the entire power range, especially at medium and low power levels. Although the proposed control strategy can be generalized for different topologies and specifications, in this paper, the strategy is validated in a SiC-based synchronous boost DC/DC converter rated for 400 V to 800 V and 10 kW. Evaluation of the power losses and current waveforms of the converter for different conduction modes and loads predicts suitable performance of quasi-square wave mode with zero voltage switching (QSW-ZVS) conduction mode for low and medium power and of continuous conduction Mode with hard switching (CCM-HS) for high power. Consequently, this paper proposes a control strategy, taking advantage of digital control, that allows automatic adjustment of the conduction mode to optimize the performance for different power ranges.


2020 ◽  
Vol 10 (5) ◽  
pp. 1703 ◽  
Author(s):  
Zhao Han ◽  
Xiaoli Wang ◽  
Baochen Jiang ◽  
Jingru Chen

In microgrids, paralleled converters can increase the system capacity and conversion efficiency but also generate zero-sequence circulating current, which will distort the AC-side current and increase power losses. Studies have shown that, for two paralleled three-phase voltage-source pulse width modulation (PWM) converters with common DC bus controlled by space vector PWM, the zero-sequence circulating current is mainly related to the difference of the zero-sequence duty ratio between the converters. Therefore, based on the traditional control ideal of zero-vector action time adjustment, this paper proposes a zero-sequence circulating current suppression strategy using proportional–integral quasi-resonant control and feedforward compensation control. Firstly, the dual-loop decoupled control was utilized in a single converter. Then, in order to reduce the amplitude and main harmonic components of the circulating current, a zero-vector duty ratio adjusting factor was initially generated by a proportional–integral quasi-resonant controller. Finally, to eliminate the difference of zero-sequence duty ratio between the converters, the adjusting factor was corrected by a feedforward compensation link. The simulation mode of Matlab/Simulink was constructed for the paralleled converters based on the proposed control strategy. The results verify that this strategy can effectively suppress the zero-sequence circulating current and improve power quality.


2017 ◽  
Vol 32 (2) ◽  
pp. 1591-1601 ◽  
Author(s):  
Tsai-Fu Wu ◽  
Po-Hung Lee ◽  
Li-Chiun Lin ◽  
Chih-Hao Chang ◽  
Yu-Kai Chen

Sign in / Sign up

Export Citation Format

Share Document