scholarly journals High Energy Resolution Hard X-Ray and Gamma-Ray Imagers Using CdTe Diode Devices

2009 ◽  
Vol 56 (3) ◽  
pp. 777-782 ◽  
Author(s):  
Shin Watanabe ◽  
Shin-nosuke Ishikawa ◽  
Hiroyuki Aono ◽  
Shin'ichiro Takeda ◽  
Hirokazu Odaka ◽  
...  
2017 ◽  
Vol 139 (49) ◽  
pp. 18024-18033 ◽  
Author(s):  
Rebeca G. Castillo ◽  
Rahul Banerjee ◽  
Caleb J. Allpress ◽  
Gregory T. Rohde ◽  
Eckhard Bill ◽  
...  

2015 ◽  
Vol 112 (52) ◽  
pp. 15803-15808 ◽  
Author(s):  
Ofer Hirsch ◽  
Kristina O. Kvashnina ◽  
Li Luo ◽  
Martin J. Süess ◽  
Pieter Glatzel ◽  
...  

The lanthanum-based materials, due to their layered structure and f-electron configuration, are relevant for electrochemical application. Particularly, La2O2CO3 shows a prominent chemoresistive response to CO2. However, surprisingly less is known about its atomic and electronic structure and electrochemically significant sites and therefore, its structure–functions relationships have yet to be established. Here we determine the position of the different constituents within the unit cell of monoclinic La2O2CO3 and use this information to interpret in situ high-energy resolution fluorescence-detected (HERFD) X-ray absorption near-edge structure (XANES) and valence-to-core X-ray emission spectroscopy (vtc XES). Compared with La(OH)3 or previously known hexagonal La2O2CO3 structures, La in the monoclinic unit cell has a much lower number of neighboring oxygen atoms, which is manifested in the whiteline broadening in XANES spectra. Such a superior sensitivity to subtle changes is given by HERFD method, which is essential for in situ studying of the interaction with CO2. Here, we study La2O2CO3-based sensors in real operando conditions at 250 °C in the presence of oxygen and water vapors. We identify that the distribution of unoccupied La d-states and occupied O p- and La d-states changes during CO2 chemoresistive sensing of La2O2CO3. The correlation between these spectroscopic findings with electrical resistance measurements leads to a more comprehensive understanding of the selective adsorption at La site and may enable the design of new materials for CO2 electrochemical applications.


2017 ◽  
Author(s):  
Juan C. Nino ◽  
James Baciak ◽  
Paul Johns ◽  
Soumitra Sulekar ◽  
James Totten ◽  
...  

2013 ◽  
Vol 19 (S2) ◽  
pp. 1258-1259 ◽  
Author(s):  
H. Takahashi ◽  
N. Handa ◽  
T. Murano ◽  
M. Terauchi ◽  
M. Koike ◽  
...  

Extended abstract of a paper presented at Microscopy and Microanalysis 2013 in Indianapolis, Indiana, USA, August 4 – August 8, 2013.


1996 ◽  
Vol 67 (9) ◽  
pp. 3359-3359 ◽  
Author(s):  
Wolfgang A. Caliebe ◽  
Sas̆a Bajt ◽  
Chi‐Chang Kao

2014 ◽  
Vol 24 (03n04) ◽  
pp. 205-215
Author(s):  
M. Kavčič

While traditional proton induced X-ray emission (PIXE) analytical technique is based on the energy dispersive solid state detectors used to collect the X-ray fluorescence from the sample, wavelength dispersive X-ray (WDX) spectrometers are applied in high energy resolution PIXE (HR-PIXE) analysis. The main drawback of the WDX spectroscopy is the relatively low efficiency making it less applicable for trace element PIXE analysis. However, the efficiency was enhanced significantly in modern spectrometers employing cylindrically or even spherically curved crystals combined with position sensitive X-ray detectors. The energy resolution of such a spectrometer may exceed the resolution of the energy dispersive detector by two orders of magnitude while keeping the efficiency at a high enough level to perform trace element analysis. In this paper, the recent history and the development of HR-PIXE spectroscopy at the J. Stefan Institute in Ljubljana is presented. Our current setup based on in-vacuum Johansson-type crystal spectrometer is presented in more details followed by some most recent applications.


Sign in / Sign up

Export Citation Format

Share Document