Effects of Breakdown Voltage on Single Event Burnout Tolerance of High-Voltage SiC Power MOSFETs

Author(s):  
D.R. Ball ◽  
K.F. Galloway ◽  
R.A. Johnson ◽  
M.L. Alles ◽  
A.L. Sternberg ◽  
...  
Author(s):  
K. Muthuseenu ◽  
H. J. Barnaby ◽  
K. F. Galloway ◽  
A. E. Koziukov ◽  
T. A. Maksimenko ◽  
...  

2020 ◽  
Vol 67 (1) ◽  
pp. 22-28 ◽  
Author(s):  
D. R. Ball ◽  
J. M. Hutson ◽  
A. Javanainen ◽  
J.-M. Lauenstein ◽  
K. F. Galloway ◽  
...  

1992 ◽  
Vol 39 (6) ◽  
pp. 1698-1703 ◽  
Author(s):  
S. Kuboyama ◽  
S. Matsuda ◽  
T. Kanno ◽  
T. Ishii

Author(s):  
Luigi Balestra ◽  
Susanna Reggiani ◽  
Antonio Gnudi ◽  
Elena Gnani ◽  
Jagoda Dobrzynska ◽  
...  

2018 ◽  
Vol 201 ◽  
pp. 02004
Author(s):  
Shao-Ming Yang ◽  
Gene Sheu ◽  
Tzu Chieh Lee ◽  
Ting Yao Chien ◽  
Chieh Chih Wu ◽  
...  

High performance power device is necessary for BCD power device. In this paper, we used 3D Synopsis TCAD simulation tool Sentaurus to develop 120V device and successfully simulated. We implemented in a conventional 0.35um BCDMOS process to present of a novel high side 120V LDMOS have reduced surface field (RESURF) and Liner p-top structure with side isolation technology. The device has been research to achieve a benchmark specific on-resistance of 189 mΩ-mm2 while maintaining horizontal breakdown voltage and vertical isolation voltage both to target breakdown voltage of 120V. In ESOA, we also proposed a better performance of both device without kirk effect.


2018 ◽  
Vol 17 (2) ◽  
pp. 1-5
Author(s):  
Noor Azlinda Ahmad ◽  
Rosniza Zainal ◽  
Zuraimy Adzis

This paper investigates the voltage breakdown characteristics of three types of lightning rods - blunt, sharp and flat. The objectives of this study are to determine the voltage breakdown characteristics of various types of lightning rods and to obtain the striking distance of each rod. A series of experiments were conducted in the high voltage laboratory consisting of individual testing rod, competitive testing rod and also horizontal distance changing. All three types of rods have been tested in each experiment in order to obtain a comprehensive result. The blunt rod has been proven as the best strike receptor in comparison to sharp and flat rod. This is because breakdown voltage for blunt rod is much lower (199 kV) than that of flat and sharp rod. Therefore, replacement of widely used sharp rod with the blunt one should be considered in order to provide better protection for buildings from lightning activities. 


2021 ◽  
Author(s):  
Chao Peng ◽  
Zhifeng Lei ◽  
Ziwen Chen ◽  
Shaozhong Yue ◽  
Zhangang Zhang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document