scholarly journals High-resolution and high-sensitivity blood flow estimation using optimization approaches with application to vascularization imaging

Author(s):  
H. Shen ◽  
C. Barthelemy ◽  
E. Khoury ◽  
Y. Zemmoura ◽  
JP. Remenieras ◽  
...  
Author(s):  
Jonathan Poree ◽  
Thomas Deffieux ◽  
Mathieu Pernot ◽  
Charlie Demene ◽  
Jerome Baranger ◽  
...  

Author(s):  
Kazumichi Ogura ◽  
Michael M. Kersker

Backscattered electron (BE) images of GaAs/AlGaAs super lattice structures were observed with an ultra high resolution (UHR) SEM JSM-890 with an ultra high sensitivity BE detector. Three different types of super lattice structures of GaAs/AlGaAs were examined. Each GaAs/AlGaAs wafer was cleaved by a razor after it was heated for approximately 1 minute and its crosssectional plane was observed.First, a multi-layer structure of GaAs (100nm)/AlGaAs (lOOnm) where A1 content was successively changed from 0.4 to 0.03 was observed. Figures 1 (a) and (b) are BE images taken at an accelerating voltage of 15kV with an electron beam current of 20pA. Figure 1 (c) is a sketch of this multi-layer structure corresponding to the BE images. The various layers are clearly observed. The differences in A1 content between A1 0.35 Ga 0.65 As, A1 0.4 Ga 0.6 As, and A1 0.31 Ga 0.69 As were clearly observed in the contrast of the BE image.


2021 ◽  
pp. svn-2020-000636
Author(s):  
Miaoqi Zhang ◽  
Fei Peng ◽  
Xin Tong ◽  
Xin Feng ◽  
Yunduo Li ◽  
...  

Background and purposePrevious studies have reported about inflammation processes (IPs) that play important roles in aneurysm formation and rupture, which could be driven by blood flow. IPs can be identified using aneurysmal wall enhancement (AWE) on high-resolution black-blood MRI (BB-MRI) and blood flow haemodynamics can be demonstrated by four-dimensional-flow MRI (4D-flow MRI). Thus, this study investigated the associations between AWE and haemodynamics in unruptured intracranial aneurysms (IA) by combining 4D-flow MRI and high-resolution BB-MRI.Materials and methodsBetween April 2014 and October 2017, 48 patients with 49 unruptured IA who underwent both 4D-flow MRI and high-resolution BB-MRI were retrospectively included in this study. The haemodynamic parameters demonstrated using 4D-flow MRI were compared between different AWE patterns using the Kruskal-Wallis test and ordinal regression.ResultsThe results of Kruskal-Wallis test showed that the average wall shear stress in the IA (WSSavg-IA), maximum through-plane velocity in the adjacent parent artery, inflow jet patterns and the average vorticity in IA (vorticityavg-IA) were significantly associated with the AWE patterns. Ordinal regression analysis identified WSSavg-IA (p=0.002) and vorticityavg-IA (p=0.033) as independent predictors of AWE patterns.ConclusionA low WSS and low average vorticity were independently associated with a high AWE grade for IAs larger than 4 mm. Therefore, WSS and average vorticity could predict AWE and circumferential AWE.


2015 ◽  
Vol 204 (3) ◽  
pp. 510-518 ◽  
Author(s):  
Hadrien A. Dyvorne ◽  
Ashley Knight-Greenfield ◽  
Cecilia Besa ◽  
Nancy Cooper ◽  
Julio Garcia-Flores ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document