Interference in the anti‐Xa heparin activity assay due to hemolysis and icterus during pediatric extracorporeal life support

2019 ◽  
Vol 43 (9) ◽  
pp. 880-887 ◽  
Author(s):  
Jenna Khan ◽  
Wayne L. Chandler
1998 ◽  
Vol 21 (5) ◽  
pp. 291-298 ◽  
Author(s):  
P.W. Weerwind ◽  
F.H. Van Der Veen ◽  
T. Lindhout ◽  
D.S. De Jong ◽  
P.T. Cahalan

In this study the intrinsic thrombogenicity of the extracorporeal circuits and the benefit of heparin-bonded circuits in an extracorporeal life support system without full systemic heparinization and with minimal interference of the so called material-independent factors was tested in four calves. In two circuits (group A) all blood-contacting surfaces were coated with end-point-attached heparin and the other two were non-coated (group B). Under standardized conditions the calves were perfused at a blood flow rate of 2 L/min. After only one bolus injection of heparin (250 IU/kg body weight) before cannulation, plasma heparin activity rapidly decreased in both groups: half life of about 55 minutes. This decrease of the heparin activity was accompanied by a fall of the activated clotting time (ACT) level to baseline values. The experiments using a heparin-coated circuit, had a runtime of more than 360 minutes, whereas the experiments using a non-coated circuit had to be terminated after a runtime of 255 minutes, because massive fibrin formation was noticed in the circuit. This formation was accompanied by a rapid increase in the line pressure, measured just before the inlet of the oxygenator. The macroscopic inspections after terminating the experiments and rinsing the circuit showed a clean circuit in group A. The fibrinopeptide A (FPA) level increased faster during perfusion with the non-coated circuit than in the heparin coated circuit. Lung histopathological examinations of the lungs of the animals in group A showed no fibrin deposition, whereas most of the blood vessels of the lung preparations of the animals in group B were partially or completely occluded with fibrin. These results suggest that heparin-bonding greatly reduces the thrombogenicity of the extracorporeal circuit, and therefore it can reduce the need for systemic heparinization in an extracorporeal life support system.


2019 ◽  
Vol 152 (Supplement_1) ◽  
pp. S3-S4
Author(s):  
Jenna Khan ◽  
Wayne Chandler

Abstract The presence of hemolysis or icterus can interfere with chromogenic anti-Xa assays for unfractionated heparin monitoring (heparin activity), resulting in falsely lower estimates of heparin activity. Dilution is a common method for mitigating interference in spectroscopic assays that measure a single analyte by endpoint analysis and has been proposed as a solution for hemolysis interference in heparin activity assays. Heparin activity assays measure heparin/antithrombin complex activity using a chromogenic rate of absorbance change method. Heparin activity is a complex equilibrium of heparin binding to multiple proteins, including antithrombin, heparin cofactor II, platelet factor 4, histidine-rich glycoprotein, vitronectin, fibronectin, and others; some enhance while others neutralize heparin activity. The objective of this study was to determine how dilution affects heparin activity with different starting levels of antithrombin. First samples were diluted without interference (no hemolysis). Samples with 1 U/mL heparin in pooled normal plasma (PNP) and 50% PNP (to simulate 50% antithrombin levels) were diluted 1:1 with PNP versus OK buffer. Dilution resulted in nonlinear changes. Samples with 100% antithrombin recovered 88% of expected activity with PNP versus 74% with OK buffer; samples with 50% antithrombin recovered 111% with PNP versus 77% with OK buffer. Samples were then spiked with varying concentrations of hemolysate and 1:1 dilutions with PNP demonstrated nonlinear recoveries ranging from 41% to 84%. We were unable to recover the original heparin activity with or without hemolysis due to the complex interaction of initial heparin, antithrombin, and other binding protein concentrations with diluent antithrombin and other diluent heparin binding protein levels. When PNP is used as the diluent, the recovery will be lower when the initial antithrombin level is normal due to the addition of other heparin binding proteins; when the initial antithrombin level is low, the recovery is higher due to the addition of antithrombin from the diluent plasma. The recovery is always lower when buffer is used due to dilution of sample antithrombin. Careful consideration should be taken in evaluating the utility of sample dilution to mitigate interference from hemolysis and icterus in heparin activity assays, particularly in patients with fluctuating levels of antithrombin, such as those on extracorporeal life support or with liver failure.


2020 ◽  
Vol 99 (10) ◽  

Besides the conventional extracorporeal circulation, commonly used in cardiac surgery, the methods of extracorporeal life support (ECLS) have been applied ever more frequently in thoracic surgery in recent years. The most commonly used modalities of such supports include extracorporeal membrane oxygenation (ECMO) and the Novalung interventional lung assist device (iLA). Successful application of ECLS has led to its more frequent use in general thoracic surgery, especially as a tool to treat hypercapnia and to ensure oxygenation and haemodynamic support. However, these methods are essential in lung transplant programmes; without their help, in most cases, it would not be possible to perform the transplantatioz or prevent the severe complications associated with critical primary graft dysfunction. Additionally, the extracorporeal circulation also facilitates the performing of specific surgical procedures that would not be feasible under standard conditions or would be associated with an inadequate risk. The application of extracorporeal life supports can fundamentally increase the level of resection when treating advanced intrathoracic malignancies that are in close contact with the heart and large vessels or even directly extend into them. Without the possibility of resecting such structures en bloc, together with the tumour, and, thus, achieving an R0 resection, these malignant tumours are often directly contraindicated for surgery or are operated non-radically, i.e. unsuccessfully. Complete tumour resection is the most important prognostic factor in the surgery.


2014 ◽  
Vol 17 (5) ◽  
pp. 253 ◽  
Author(s):  
Sabina P W Guenther ◽  
Sven Peterss ◽  
Angela Reichelt ◽  
Frank Born ◽  
Matthias Fischer ◽  
...  

<p><b>Background:</b> Myocardial ischemia due to concomitant coronary artery disease (CAD) or coronary dissection in patients with acute aortic dissection type Stanford A (AADA) is associated with myocardial failure and poor outcomes. Preoperative coronary angiography in this group of patients is still debated. The use of CT scan to diagnose coronary affection along with the establishment of high-pitched dual-spiral CT protocols are essential for improving outcomes.</p><p><b>Methods:</b> We retrospectively analyzed six AADA patients with heart failure who were treated using extracorporeal life support (ECLS). Options for diagnosing coronary affection and different therapeutic strategies for postcardiotomy cardiogenic shock in this patient cohort are discussed.</p><p><b>Results:</b> Retrospective review of CT images showed coronary abnormalities in 83% (n = 5). Four patients (67%) underwent unplanned coronary artery bypass grafting (CABG). ECLS was instituted in 67% (n = 4) due to left heart failure and in 33% (n = 2) due to right heart failure. Thirty day mortality was 67% (n = 4). The two patients that received ECLS for right ventricular support survived and both had undergone CABG.</p><p><b>Conclusion:</b> Besides preoperative evaluation of the extent of the dissection, focus on coronary affection in CT-scans helps to triage the operative procedure. Hybrid operating rooms allow for immediate interventional and/or surgical treatment and enable for immediate control of revascularization results. The use of ECLS over other types of ventricular support systems may allow for myocardial recovery in selected cases.</p>


Sign in / Sign up

Export Citation Format

Share Document