Respiratory impedance is correlated with airway narrowing in asthma using three-dimensional computed tomography

2018 ◽  
Vol 48 (3) ◽  
pp. 278-287 ◽  
Author(s):  
M. Karayama ◽  
N. Inui ◽  
K. Mori ◽  
M. Kono ◽  
H. Hozumi ◽  
...  
2017 ◽  
Vol 123 (5) ◽  
pp. 1188-1194 ◽  
Author(s):  
Catherine E. Farrow ◽  
Cheryl M. Salome ◽  
Benjamin E. Harris ◽  
Dale L. Bailey ◽  
Norbert Berend ◽  
...  

In asthma, bronchoconstriction causes topographically heterogeneous airway narrowing, as measured by three-dimensional ventilation imaging. Computation modeling suggests that peripheral airway dysfunction is a potential determinant of acute airway narrowing measured by imaging. We hypothesized that the development of low-ventilation regions measured topographically by three-dimensional imaging after bronchoconstriction is predicted by peripheral airway function. Fourteen asthmatic subjects underwent ventilation single-photon-emission computed tomography/computed tomography scan imaging before and after methacholine challenge. One-liter breaths of Technegas were inhaled from functional residual capacity in upright posture before supine scanning. The lung regions with the lowest ventilation (Ventlow) were calculated using a thresholding method and expressed as a percentage of total ventilation (Venttotal). Multiple-breath nitrogen washout was used to measure diffusion-dependent and convection-dependent ventilation heterogeneity (Sacin and Scond, respectively) and lung clearance index (LCI), before and after challenge. Forced expiratory volume in 1 s (FEV1) was 87.6 ± 15.8% predicted, and seven subjects had airway hyperresponsiveness. Ventlow at baseline was unrelated to spirometry or multiple-breath nitrogen washout indices. Methacholine challenge decreased FEV1 by 23 ± 5% of baseline while Ventlow increased from 21.5 ± 2.3%Venttotal to 26.3 ± 6.7%Venttotal ( P = 0.03). The change in Ventlow was predicted by baseline Sacin ( rs = 0.60, P = 0.03) and by LCI ( rs = 0.70, P = 0.006) but not by Scond ( rs = 0.30, P = 0.30). The development of low-ventilation lung units in three-dimensional ventilation imaging is predicted by ventilation heterogeneity in diffusion-dependent airways. This relationship suggests that acinar ventilation heterogeneity in asthma may be of mechanistic importance in terms of bronchoconstriction and airway narrowing. NEW & NOTEWORTHY Using ventilation SPECT/CT imaging in asthmatics, we show induced bronchoconstriction leads to the development of areas of low ventilation. Furthermore, the relative volume of the low-ventilation regions was predicted by ventilation heterogeneity in diffusion-dependent acinar airways. This suggests that the pattern of regional airway narrowing in asthma is determined by acinar airway function.


Author(s):  
H.W. Deckman ◽  
B.F. Flannery ◽  
J.H. Dunsmuir ◽  
K.D' Amico

We have developed a new X-ray microscope which produces complete three dimensional images of samples. The microscope operates by performing X-ray tomography with unprecedented resolution. Tomography is a non-invasive imaging technique that creates maps of the internal structure of samples from measurement of the attenuation of penetrating radiation. As conventionally practiced in medical Computed Tomography (CT), radiologists produce maps of bone and tissue structure in several planar sections that reveal features with 1mm resolution and 1% contrast. Microtomography extends the capability of CT in several ways. First, the resolution which approaches one micron, is one thousand times higher than that of the medical CT. Second, our approach acquires and analyses the data in a panoramic imaging format that directly produces three-dimensional maps in a series of contiguous stacked planes. Typical maps available today consist of three hundred planar sections each containing 512x512 pixels. Finally, and perhaps of most import scientifically, microtomography using a synchrotron X-ray source, allows us to generate maps of individual element.


Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 757
Author(s):  
Maged Sultan Alhammadi ◽  
Abeer Abdulkareem Al-mashraqi ◽  
Rayid Hussain Alnami ◽  
Nawaf Mohammad Ashqar ◽  
Omar Hassan Alamir ◽  
...  

The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18–30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland–Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.


2021 ◽  
Author(s):  
Katherine A. Wolcott ◽  
Guillaume Chomicki ◽  
Yannick M. Staedler ◽  
Krystyna Wasylikowa ◽  
Mark Nesbitt ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document