Study on Polishing Method Using Double Magnet System by Superconductive Assisted Machining Method

2021 ◽  
Author(s):  
Keisuke Suzuki ◽  
Tatsuya Nakasaki ◽  
Hidetaka Nakashim ◽  
Panart Khajornrungrungang ◽  
Yushi Kinoshita ◽  
...  
Keyword(s):  
1984 ◽  
Vol 45 (C1) ◽  
pp. C1-233-C1-239 ◽  
Author(s):  
L. Resegotti
Keyword(s):  

2002 ◽  
Vol 90 ◽  
pp. 65-66 ◽  
Author(s):  
Kazuya Oguri ◽  
Akihiro Mizutani ◽  
Sanshiro Ogino ◽  
Yasuzumi Ochial ◽  
Yoshitake Nishi
Keyword(s):  

2020 ◽  
Vol 64 (1-4) ◽  
pp. 1495-1504
Author(s):  
Fangchao Xu ◽  
Yongquan Guo ◽  
Ran Zhou ◽  
Junjie Jin ◽  
Chuan Zhao ◽  
...  

To solve the problem of reduction of suspension force of permanent magnet system with variable magnetic flux path control, according to the structure of the system, suspension principle of the permanent magnet system with variable magnetic flux path control and the generation principle of the load torque, the influence of the mechanical structure of the system on the suspension force is analyzed by changing part of parameters of the system structure. The results show that the existence of magnetic isolation plate is the main reason for the decrease of suspension force, the permanent magnet ring can be thickened to 11.91 mm, the annular gap can be reduced to 1 mm, thickness of the “F” shaped magnetizer can be increased to 9 mm to increase the suspension force.


1998 ◽  
Author(s):  
Ch. Stenzel ◽  
H. Lenski ◽  
P. Dold ◽  
Th. Kaiser ◽  
K.-W. Benz ◽  
...  

1964 ◽  
Vol 42 (7) ◽  
pp. 1343-1357 ◽  
Author(s):  
Richard Stevenson

This paper contains a design of an aluminum solenoid magnet system capable of producing a field of 300 000 Oe over a bore of 5.8 cm. The magnetic field is produced by a two-region solenoid operated at 15 °K and cooled by compressed helium gas. Details of the structure are described, and calculations are given for all important parts of the cooling system. The magnet is designed for a total operating time at maximum power of at least 40 minutes in a week. The low capital expense of the system makes it suitable for installation in small laboratories.


Author(s):  
Pietro Canzi ◽  
Marianna Magnetto ◽  
Anna Simoncelli ◽  
Marco Manfrin ◽  
Federico Aprile ◽  
...  

Abstract Purposes To investigate the effects for Ultra 3D cochlear implant (CI) positioning on MR imaging quality, looking at a comprehensive description of intracranial structures in cases of unilateral and bilateral CI placement. Methods Four CI angular positions (90°, 120°, 135° and 160°) at 9 cm distance from the outer-ear canal were explored. The 1.5 T MRI assessment included our institutional protocol for the investigation of brain pathologies without gadolinium application. Three investigators (two experienced neuroradiologists and one experienced otoneurosurgeon) independently evaluated the MR findings. A 4-point scale was adopted to describe 14 intracranial structures and to determine which CI positioning allowed the best image quality score and how bilateral CI placement modified MRI scan visibility. Results A high positive correlation was found between the three blinded observers. Structures situated contralateral from the CI showed high-quality values in all four placements. Structures situated ipsilaterally provided results suitable for diagnostic purposes for at least one position. At 90°, artifacts mainly involved brain structures located cranially and anteriorly (e.g., temporal lobe); on the contrary, at 160°, artifacts mostly influenced the posterior fossa structures (e.g., occipital lobe). For the bilateral CI condition, MR imaging examination revealed additional artifacts involving all structures located close to either CI, where there was a signal void/distortion area. Conclusions Suitable unilateral CI positioning can allow the visualization of intracranial structures with sufficient visibility for diagnostic purposes. Bilateral CI positioning significantly deteriorates the anatomical visibility. CI positioning might play a crucial role for patients who need post-operative MRI surveillance.


2021 ◽  
Vol 11 (7) ◽  
pp. 3074
Author(s):  
Jae Young Jang ◽  
Myung Su Kim ◽  
Young Jin Hwang ◽  
Seunghyun Song ◽  
Yojong Choi ◽  
...  

A cryogen-free portable 3 T high-temperature superconducting magnet for an electromagnetic property measurement system has been developed to serve as a user facility at the Korea Basic Science Institute. The metallic insulation method was adopted to reduce the charging delay without sacrificing the self-protecting feature. A genetic-algorithm-aided optimized design was carried out to minimize the superconducting tape consumption while satisfying several design constraints. After the design, the compact high-temperature superconducting magnet composed of eight double-pancake coil modules was wound with high-temperature superconducting tape and stainless steel tape, and integrated with a two-stage cryo-cooler. The 3 T magnet was successfully cooled to approximately 20 K with a cryo-cooler and reached the target field of 3 T without any problems. Long-term measurements and a range of other tests were also implemented to verity the performance of the magnet. Test results demonstrated the feasibility of a cryogen-free portable high-temperature superconducting magnet system for electromagnetic property measurement experiments.


Sign in / Sign up

Export Citation Format

Share Document