Localized Heat Transfer in Buoyancy Driven Convection in Open Cavities

2006 ◽  
Vol 129 (2) ◽  
pp. 167-178 ◽  
Author(s):  
Wilson Terrell ◽  
Ty A. Newell

Background. An experimental study of buoyancy driven convection heat transfer in an open cavity was conducted. Method of Approach. Test cavities were constructed with calorimeter plates bonded to Styrofoam insulation. The inside of the cavities was heated and then exposed to ambient air for approximately thirty minutes. Different size cavities were examined at inclination angles of 0, 45, and 90deg. The heat transfer coefficient was determined from an energy balance on each calorimeter plate. The cavity’s plate temperatures varied spatially due to the transient nature of the tests. A parameter describing the nonisothermal cavity wall temperature variation was defined in order to compare with isothermal cavity heat transfer results. Results. Results showed that the cavity Nusselt number, based on a cavity averaged temperature, was insensitive to the transient development of nonisothermal conditions within the cavity. Comparison of cavity-average Nusselt number for the current study, where the Rayleigh number ranged from 5×106 to 2×108, to data from the literature showed good agreement. Cavity-average Nusselt number relations for inclination angles of 0, 45, and 90deg in the form of NuH,cav=CRa1∕3 resulted in coefficients of 0.091, 0.105, 0.093, respectively. The 45deg inclination angle orientation yielded the largest Nusselt numbers, which was similar to previous literature results. Trends in the local plate Nusselt numbers were examined and found similar to data from the literature.

Author(s):  
Jaspinder Kaur ◽  
Roderick Melnik ◽  
Anurag Kumar Tiwari

Abstract In this present work, forced convection heat transfer from a heated blunt-headed cylinder in power-law fluids has been investigated numerically over the range of parameters, namely, Reynolds number (Re): 1–40, Prandtl number (Pr): 10–100 and power-law index (n): 0.3–1.8. The results are expressed in terms of local parameters, like streamline, isotherm, pressure coefficient, and local Nusselt number and global parameters, like wake length, drag coefficient, and average Nusselt number. The length of the recirculation zone on the rear side of the cylinder increases with the increasing value of Re and n. The effect of the total drag coefficient acting on the cylinder is seen to be higher at the low value of Re and its effect significant in shear-thinning fluids (n < 1). On the heat transfer aspect, the rate of heat transfer in fluids is increased by increasing the value of Re and Pr. The effect of heat transfer is enhanced in shear-thinning fluids up to ∼ 40% and it impedes it’s to ∼20% shear-thickening fluids. In the end, the numerical results of the total drag coefficient and average Nusselt number (in terms of J H −factor) have been correlated by simple expression to estimate the intermediate value for the new application.


Author(s):  
Ali Rahimi Gheynani ◽  
Omid Ali Akbari ◽  
Majid Zarringhalam ◽  
Gholamreza Ahmadi Sheikh Shabani ◽  
Abdulwahab A. Alnaqi ◽  
...  

Purpose Although many studies have been conducted on the nanofluid flow in microtubes, this paper, for the first time, aims to investigate the effects of nanoparticle diameter and concentration on the velocity and temperature fields of turbulent non-Newtonian Carboxymethylcellulose (CMC)/copper oxide (CuO) nanofluid in a three-dimensional microtube. Modeling has been done using low- and high-Reynolds turbulent models. CMC/CuO was modeled using power law non-Newtonian model. The authors obtained interesting results, which can be helpful for engineers and researchers that work on cooling of electronic devices such as LED, VLSI circuits and MEMS, as well as similar devices. Design/methodology/approach Present numerical simulation was performed with finite volume method. For obtaining higher accuracy in the numerical solving procedure, second-order upwind discretization and SIMPLEC algorithm were used. For all Reynolds numbers and volume fractions, a maximum residual of 10−6 is considered for saving computer memory usage and the time for the numerical solving procedure. Findings In constant Reynolds number and by decreasing the diameter of nanoparticles, the convection heat transfer coefficient increases. In Reynolds numbers of 2,500, 4,500 and 6,000, using nanoparticles with the diameter of 25 nm compared with 50 nm causes 0.34 per cent enhancement of convection heat transfer coefficient and Nusselt number. Also, in Reynolds number of 2,500, by increasing the concentration of nanoparticles with the diameter of 25 nm from 0.5 to 1 per cent, the average Nusselt number increases by almost 0.1 per cent. Similarly, In Reynolds numbers of 4,500 and 6,000, the average Nusselt number increases by 1.8 per cent. Research limitations/implications The numerical simulation was carried out for three nanoparticle diameters of 25, 50 and 100 nm with three Reynolds numbers of 2,500, 4,500 and 6,000. Constant heat flux is on the channel, and the inlet fluid becomes heated and exists from it. Practical implications The authors obtained interesting results, which can be helpful for engineers and researchers that work on cooling of electronic devices such as LED, VLSI circuits and MEMS, as well as similar devices. Originality/value This manuscript is an original work, has not been published and is not under consideration for publication elsewhere. About the competing interests, the authors declare that they have no competing interests.


1970 ◽  
Vol 39 (1) ◽  
pp. 1-7 ◽  
Author(s):  
Sumon Saha ◽  
Noman Hasan ◽  
Chowdhury Md Feroz

A numerical study has been carried out for laminar natural convection heat transfer within a two-dimensional modified square enclosure having a triangular roof. The vertical sidewalls are differentially heated considering a constant flux heat source strip is flush mounted with the left wall. The opposite wall is considered isothermal having a temperature of the surrounding fluid. The rest of the walls are adiabatic. Air is considered as the fluid inside the enclosure. The solution has been carried out on the basis of finite element analysis by a non-linear parametric solver to examine the heat transfer and fluid flow characteristics. Different heights of the triangular roof have been considered for the present analysis. Fluid flow fields and isotherm patterns and the average Nusselt number are presented for the Rayleigh numbers ranging from 103 to 106 in order to show the effects of these governing parameters. The average Nusselt number computed for the case of isoflux heating is also compared with the case of isothermal heating as available in the literature. The outcome of the present investigation shows that the convective phenomenon is greatly influenced by the inclined roof height. Keywords: Natural convection, triangular roof, Rayleigh number, isoflux heating. Doi:10.3329/jme.v39i1.1826 Journal of Mechanical Engineering, vol. ME39, No. 1, June 2008 1-7


Author(s):  
M. R. Salem ◽  
K. M. Elshazly ◽  
R. Y. Sakr ◽  
R. K. Ali

The present work experimentally investigates the characteristics of convective heat transfer in horizontal shell and coil heat exchangers in addition to friction factor for fully developed flow through the helically coiled tube (HCT). The majority of previous studies were performed on HCTs with isothermal and isoflux boundary conditions or shell and coil heat exchangers with small ranges of HCT configurations and fluid operating conditions. Here, five heat exchangers of counter-flow configuration were constructed with different HCT-curvature ratios (δ) and tested at different mass flow rates and inlet temperatures of the two sides of the heat exchangers. Totally, 295 test runs were performed from which the HCT-side and shell-side heat transfer coefficients were calculated. Results showed that the average Nusselt numbers of the two sides of the heat exchangers and the overall heat transfer coefficients increased by increasing coil curvature ratio. The average increase in the average Nusselt number is of 160.3–80.6% for the HCT side and of 224.3–92.6% for the shell side when δ increases from 0.0392 to 0.1194 within the investigated ranges of different parameters. Also, for the same flow rate in both heat exchanger sides, the effect of coil pitch and number of turns with the same coil torsion and tube length is remarkable on shell average Nusselt number while it is insignificant on HCT-average Nusselt number. In addition, a significant increase of 33.2–7.7% is obtained in the HCT-Fanning friction factor (fc) when δ increases from 0.0392 to 0.1194. Correlations for the average Nusselt numbers for both heat exchanger sides and the HCT Fanning friction factor as a function of the investigated parameters are obtained.


1984 ◽  
Vol 106 (1) ◽  
pp. 109-115 ◽  
Author(s):  
H. Inaba ◽  
T. Fukuda

An experimental investigation pertaining to the effect of the density inversion of water on steady natural convective flow patterns and heat transfer in an inclined rectangular cavity whose two opposing walls are kept at different temperatures is carried out. Water as a testing fluid has its maximum density at about 4 °C. The temperature of one wall is maintained at 0 °C, while that of the opposing hot wall is varied from 2 to 20 °C. Photographs of the flow patterns, temperature distribution in the water layer, and average Nusselt number are presented under various hot wall temperatures and inclination angles of the cavity. The present results could indicate that the density inversion of water has an influential effect on the natural convective heat transfer in the prescribed water layer. Moreover, the average Nusselt number is a peculiar function of the temperature difference between the cold and hot walls and inclination angle, unlike the previous results for common fluids without density inversion.


2020 ◽  
Author(s):  
Sattar Aljobair ◽  
Akeel Abdullah Mohammed ◽  
Israa Alesbe

Abstract The natural convection heat transfer and fluid flow characteristic of water based Al2O3 nano-fluids in a symmetrical and unsymmetrical corrugated annulus enclosure has been studied numerically using CFD. The inner cylinder is heated isothermally while the outer cylinder is kept constant cold temperature. The study includes eight models of corrugated annulus enclosure with constant aspect ratio of 1.5. The governing equations of fluid motion and heat transfer are solved using stream-vorticity formulation in curvilinear coordinates. The range of solid volume fractions of nanoparticles extends from PHI=0 to 0.25, and Rayleigh number varies from 104 to 107. Streamlines, isotherms, local and average Nusselt number of inner and outer cylinder has been investigated in this study. Sixty-four correlations have been deduced for the average Nusselt number for the inner and outer cylinders as a function of Rayleigh number have been deduced for eight models and five values of volume fraction of nano particles with an accuracy range 6-12 %. The results show that, the average heat transfer rate increases significantly as particle volume fraction and Rayleigh number increase. Also, increase the number of undulations in unsymmetrical annuli reduces the heat transfer rates which remain higher than that in symmetrical annuli. There is no remarkable change in isotherms contour with increase of volume fraction of nanofluid.


2021 ◽  
Vol 39 (5) ◽  
pp. 1634-1642
Author(s):  
Syed Fazuruddin ◽  
Seelam Sreekanth ◽  
G Sankara Sekhar Raju

An exhaustive numerical investigation is carried out to analyze the role of an isothermal heated thin fin on fluid flow and temperature distribution visualization in an enclosure. Natural convection within square enclosures finds remarkable pragmatic applications. In the present study, a finite difference approach is performed on two-dimensional laminar flow inside an enclosure with cold side walls and adiabatic horizontal walls. The fluid flow equations are reconstructed into vorticity - stream function formulation and these equations are employed utilizing the finite-difference strategy with incremental time steps. The parametric study includes a wide scope of Rayleigh number, Ra, and inclination angle ϴ of the thin fin. The effect of different Rayleigh numbers ranging Ra = 104-106 with Pr=0.71 for all the inclination angles from 0°-360° with uniform rotational length of angle 450 of an inclined heated fin on fluid flow and heat transfer have been investigated. The heat transfer rate within the enclosure is measured by means of local and average Nusselt numbers. Regardless of inclination angles of the thin fin, a slight enhancement in the average Nusselt number is observed when Rayleigh number increased for both the cases of the horizontal and vertical position of the thin fin. When the fin has inclined no change in average Nusselt number is noticed for distinct Rayleigh numbers.


Author(s):  
Tooraj Yousefi ◽  
Saeed Ebrahimi ◽  
Masood Bigharaz ◽  
Sajjad Mahmoodi Nezhad

An experimental study has been carried out to investigate heat transfer characteristics on internal surfaces of a V-shaped plate exposed to a slot jet impingement of air. A square-edged nozzle is mounted parallel with V-shaped plate axis and jet flow impinges on the bottom of the V-shaped plate. The study is focused on Rayleigh number 159000, angle of V-shaped plate ranging from 22.5 to 45 degree, low Reynolds numbers ranging from 29.05 to 60.41, and slot-to-(V-shaped plate) spacing from 17 to 21 of the slot width. A Mach-Zehnder interferometer is used for measurement of local Nusselt number on the V-shaped plate. It is observed that the local Nusselt number and average Nusselt number decrease with increasing the jet spacing and increase with increasing the Reynolds number. Also the local Nusselt number and average nusselt number increase with rising the angle of V-shaped plate.


1981 ◽  
Vol 103 (2) ◽  
pp. 249-256 ◽  
Author(s):  
W. W. Yousef ◽  
J. D. Tarasuk

A Mach-Zehnder interferometer was employed to determine the three-dimensional temperature field, and the circumferential and average Nusselt numbers for laminar flow of air in the entrance region of an isothermal horizontal tube where the velocity and the temperature profiles were developing simultaneously. The influence of free convection due to buoyancy on forced convection heat transfer was investigated. The Reynolds numbers ranged from 120 to 1200, the Grashof numbers ranged from 0.8 × 104 to 8.7 × 104, and the ratio L/D was varied from 6 to 46. The free convection increases, substantially, the average Nusselt number, by up to a factor of 2.0 from the analytical predictions, which account for forced convection only, near the tube inlet. Far from the tube inlet the free convection tends to decrease the average Nusselt number below the analytical predictions.


Author(s):  
Tooraj Yousefi ◽  
Sajjad Mahmoodi Nezhad ◽  
Masood Bigharaz ◽  
Saeed Ebrahimi

Steady state two-dimensional free convection heat transfer in a partitioned cavity with adiabatic horizontal and isothermally vertical walls and an adiabatic partition has been investigated experimentally. The experiments have been carried out using a Mach-Zehnder interferometer. The effects of the angel of the adiabatic partition and Rayleigh number on the heat transfer from the heated wall are investigated. Experiments are performed for the values of Rayleigh number based on the cavity side length in the range between 1.5×105 to 4.5×105 and various angle of the partition with respect to horizon from 0° to 90°. The results indicate that at each angle of the adiabatic partition, by increasing the Rayleigh number, the average Nusselt number and heat transfer increase and at each Rayleigh number, the maximum and the minimum heat transfer occur at θ=45° and θ=90°, respectively. A correlation based on the experimental data for the average Nusselt number of the heated wall as a function of Rayleigh number and the angel of the adiabatic partition is presented in the aforementioned ranges.


Sign in / Sign up

Export Citation Format

Share Document