The Effect of Twisted-Tape Width on Heat Transfer and Pressure Drop for Fully Developed Laminar Flow

1996 ◽  
Vol 118 (3) ◽  
pp. 584-589 ◽  
Author(s):  
W. M. Chakroun ◽  
S. F. Al-Fahed

A series of experiments was conducted to study the effect of twisted-tape width on the heat transfer and pressure drop with laminar flow in tubes. Data for three twisted-tape wavelengths, each with five different widths, have been collected with constant wall temperature boundary condition. Correlations for the friction factor and Nusselt number are also available. The correlations predict the experimental data to within 10 to 15 percent for the heat transfer and friction factor, respectively. The presence of the twisted tape has caused the friction factor to increase by a factor of 3 to 7 depending on Reynolds number and the twisted-tape geometry. Heat transfer results have shown an increase of 1.5 to 3 times that of plain tubes depending on the flow conditions and the twisted-tape geometry. The width shows no effect on friction factor and heat transfer in the low range of Reynolds number but has a more pronounced effect on heat transfer at the higher range of Reynolds number. It is recommended to use loose-fit tapes for low Reynolds number flows instead of tight-fit in the design of heat exchangers because they are easier to install and remove for cleaning purposes.

Author(s):  
Walid M. Chakroun ◽  
Sami F. Al-Fahed

A series of experiments was conducted to study the effect of twisted-tape width on the heat transfer and pressure drop with laminar flow in tubes. Data for three twisted-tape wave lengths each with five different widths have been collected with constant wall temperature boundary condition. Correlations for the friction factor and Nusselt number are also available. The correlations predict the experimental data to within 10 % to 15 % for the heat transfer and friction factor, respectively. The presence of the twisted tape has caused the friction factor to increase by a factor of 3 to 7 depending on Reynolds number and the twisted-tape geometry. Heat-transfer results have shown an increase of 1.5 to 3 times that of plain tubes depending on the flow conditions and the twisted-tape geometry. The width shows no effect on friction factor and heat transfer in the low range of Reynolds number but have a more pronounced effect on heat transfer at the higher range of Reynolds number. It is recommended to use a loose-fit tapes for low Reynolds number flows instead of tight-fit in the design of heat exchangers because they are easier to install and remove for cleaning purposes.


2012 ◽  
Vol 622-623 ◽  
pp. 796-800 ◽  
Author(s):  
M.H. Kazemi ◽  
M.A. Akhavan-Behabadi ◽  
M. Fakoor Pakdaman

Experiments are performed to investigate the single-phase flow heat transfer augmentation of MWCNT/HT-B oil in both smooth and microfinned helical tubes with constant wall temperature. The tests in laminar regime were carried out in helical tubes with three curvature ratios of 2R/d=25, 30 and 35. Flow Reynolds number varied from 170 to 1800 resulting in laminar flow regime. The effect of some parameters such as the nanoparticles concentration, the dimensionless curvature radius (2R/d) and the Reynolds number on heat transfer was investigated for the laminar flow regime. The weight fraction of nanoparticles in base fluid was less than 0.4%. within the applied range of Reynolds number; results indicated that for smooth helical tube the addition of nanoparticles to the base fluid enhanced heat transfer remarkably. However, compared to the smooth helical tube, the average heat transfer augmentation ratio due to nanoparticle addition for finned tube was small, about 17%. Also, by increasing the weight fraction of nanoparticles in microfinned helical tubes, no substantial changes were observed in the rate of heat transfer enhancement. For the pressure drop, the results show that the pressure drop of nanofluids was slightly higher than the base fluid and increase as the volume concentrations go up.


2015 ◽  
Vol 751 ◽  
pp. 245-250 ◽  
Author(s):  
Niwat Piriyarungroj ◽  
Smith Eiamsa-ard ◽  
Pongjet Promvonge ◽  
Petpices Eiamsa-Ard ◽  
Chinaruk Thianpong

The effects of loose-fit twisted tape (LFT) on the heat transfer rate, friction factor, fluid phenomena and thermal performance of a tube under constant wall temperature are examined. It is observed that apart from the rise of Reynolds number, the reduction of the clearance ratio (c/D) leads to an increase in the heat transfer and pressure loss. According to the numerical results, the heat transfer and friction factor in the tubes with loose-fit twisted tape (LFT) for the smallest clearance ratio of c/D = 0.05 are higher those other clearance ratios. In addition, the thermal performances of clearance ratio c/D = 0.05 are found to be higher than those other clearance ratios (c/D) for all Reynolds numbers examined.


2004 ◽  
Vol 127 (9) ◽  
pp. 966-977 ◽  
Author(s):  
S. K. Saha ◽  
D. N. Mallick

Abstract The present paper reports the results of an experimental investigation of the heat transfer and pressure drop characteristics of laminar flow of viscous oil through horizontal rectangular and square plain ducts and ducts inserted with full-length twisted tapes, short-length twisted tapes, and regularly spaced twisted-tape elements. Isothermal pressure drop measurements were taken in acrylic ducts. Heat transfer measurements were taken in electrically heated stainless-steel ducts imposing uniform wall heat flux boundary conditions. The duct aspect ratios AR were 1, 0.5, and 0.333. The twist ratios of the twisted tapes were y=2.692, 5.385, 2.597, 5.193, 2.308, and 4.615. Short-length tapes were 0.9, 0.7, and 0.5 times the duct length. The space ratios were s=2.692, 5.385, 2.597, 5.193, 2.308, and 4.615. Both friction factor and Nusselt number increase with decreasing y and AR for AR⩽1 and increasing Re, Sw, and Pr. As the tape-length decreases, both friction factor and Nusselt number decrease. Friction factor increases as s decreases, and Nusselt number increases as s increases. Isothermal friction factor correlation and comprehensive Nusselt number correlation have been developed to predict data reasonably well in the entire range of parameters. Performance evaluation says that short-length twisted tapes are worse and regularly spaced twisted-tape elements are better than the full-length twisted tapes.


2006 ◽  
Vol 128 (10) ◽  
pp. 1070-1080 ◽  
Author(s):  
Debashis Pramanik ◽  
Sujoy K. Saha

The heat transfer and the pressure drop characteristics of laminar flow of viscous oil through rectangular and square ducts with internal transverse rib turbulators on two opposite surfaces of the ducts and fitted with twisted tapes have been studied experimentally. The tapes have been full length, short length, and regularly spaced types. The transverse ribs in combination with full-length twisted tapes have been found to perform better than either ribs or twisted tapes acting alone. The heat transfer and the pressure drop measurements have been taken in separate test sections. Heat transfer tests were carried out in electrically heated stainless steel ducts incorporating uniform wall heat flux boundary conditions. Pressure drop tests were carried out in acrylic ducts. The flow was periodically fully developed in the regularly spaced twisted-tape elements case and decaying swirl flow in the short-length twisted tapes case. The flow characteristics are governed by twist ratio, space ratio, and length of twisted tape, Reynolds number, Prandtl number, rod-to-tube diameter ratio, duct aspect ratio, rib height, and rib spacing. Correlations developed for friction factor and Nusselt number have predicted the experimental data satisfactorily. The performance of the geometry under investigation has been evaluated. It has been found that on the basis of both constant pumping power and constant heat duty, the regularly spaced twisted-tape elements in specific cases perform marginally better than their full-length counterparts. However, the short-length twisted-tape performance is worse than the full-length twisted tapes. Therefore, full-length twisted tapes and regularly spaced twisted-tape elements in combination with transverse ribs are recommended for laminar flows. However, the short-length twisted tapes are not recommended.


Author(s):  
Sam Ghazi-Hesami ◽  
Dylan Wise ◽  
Keith Taylor ◽  
Peter Ireland ◽  
Étienne Robert

Abstract Turbulators are a promising avenue to enhance heat transfer in a wide variety of applications. An experimental and numerical investigation of heat transfer and pressure drop of a broken V (chevron) turbulator is presented at Reynolds numbers ranging from approximately 300,000 to 900,000 in a rectangular channel with an aspect ratio (width/height) of 1.29. The rib height is 3% of the channel hydraulic diameter while the rib spacing to rib height ratio is fixed at 10. Heat transfer measurements are performed on the flat surface between ribs using transient liquid crystal thermography. The experimental results reveal a significant increase of the heat transfer and friction factor of the ribbed surface compared to a smooth channel. Both parameters increase with Reynolds number, with a heat transfer enhancement ratio of up to 2.15 (relative to a smooth channel) and a friction factor ratio of up to 6.32 over the investigated Reynolds number range. Complementary CFD RANS (Reynolds-Averaged Navier-Stokes) simulations are performed with the κ-ω SST turbulence model in ANSYS Fluent® 17.1, and the numerical estimates are compared against the experimental data. The results reveal that the discrepancy between the experimentally measured area averaged Nusselt number and the numerical estimates increases from approximately 3% to 13% with increasing Reynolds number from 339,000 to 917,000. The numerical estimates indicate turbulators enhance heat transfer by interrupting the boundary layer as well as increasing near surface turbulent kinetic energy and mixing.


Author(s):  
C-C Wang ◽  
Y-P Chang ◽  
K-Y Chi ◽  
Y-J Chang

Extensive experiments on the heat transfer and pressure drop characteristics of louvre finand-tube heat exchangers were carried out. In the present study, 14 samples of non-redirection louvre fin-and-tube heat exchangers with different geometrical parameters, including the number of tube row, fin pitch and tube size, were tested in a wind tunnel. Results are presented as plots of the Fanning friction factor f and the Colburn j factor against Reynolds number based on the tube collar diameter in the range of 300–8000.


Energies ◽  
2019 ◽  
Vol 12 (14) ◽  
pp. 2702
Author(s):  
Miao Qian ◽  
Jie Li ◽  
Zhong Xiang ◽  
Chao Yan ◽  
Xudong Hu

To improve the efficiency of hydrogen-producing microreactors with non-uniform pin-fin array, the influence of the pin diameter degressive gradient of the non-uniform pin-fin array (NPFA) on heat transfer and pressure drop characteristics is analyzed in this study via numerical simulation under low Reynolds number conditions. Because correlations in prior studies cannot be used to predict the Nusselt number and pressure drop in the NPFA, new heat transfer and friction factor correlations are developed in this paper to account for the effect of the pin diameter degressive gradient, providing a method for the optimized design of the pin diameter degressive gradient for a microreactor with NPFA. The results show that the Nusselt number and friction factor under a low Reynolds number are quite sensitive to the pin diameter degressive gradient. Based on the new correlations, the exponents of the pin diameter degressive gradient for the friction factor and Nusselt number were 6.9 and 2.1, respectively, indicating the significant influence of the pin diameter degressive gradient on the thermal and hydrodynamic characteristics in the NPFA structure.


2021 ◽  
Vol 13 (8) ◽  
pp. 168781402110407
Author(s):  
Hosny Abou-Ziyan ◽  
Reda Ameen ◽  
Khairy Elsayed

This paper presents the results of fluid flow and convection heat transfer in concentric and eccentric annuli between two cylinders using a three-dimensional computational fluid dynamics model. Effects of rotational speed ( n = 0, 150, 300, and 400 rpm) and eccentricity (ε = 0, 0.15, 0.3, 0.45, and 0.6) on axial and tangential velocity distribution, pressure drop and forced convection heat transfer are investigated for radii ratios (η) of 0.2, 0.4, 0.6, and 0.8, Reynolds number 2.0 × 103–1.236 × 105, Taylor number 1.47 × 106–1.6 × 1010, and Prandtl number 3.71–6.94. The parameters cover many applications, including rotary heat exchangers, mixers, agitators, etc. Nusselt numbers and friction factors for stationary and rotated concentric and eccentric annuli are correlated with four dimensionless numbers. The results revealed that when the speed of the inner cylinder increases from 0 to 400 rpm, the friction factor increases by 7.7%–103% for concentric and 8.2%–148% for eccentric annuli, whereas Nusselt number enhances by 37%–333% for concentric and 44%–340% for eccentric annuli. The radius ratio has a substantial effect on the heat transfer and pressure drop in annuli. The eccentricity enhances the heat transfer up to 12%, whereas its effect on the friction factor is not monotonic as it depends on Reynolds number, radii ratios, and rotational speed.