Drop-Size Distributions of Newtonian Liquid Sprays Produced by Fan-Jet Pressure Nozzles

1979 ◽  
Vol 101 (2) ◽  
pp. 171-177 ◽  
Author(s):  
W. S. Janna ◽  
J. E. A. John

The drop size distribution was measured by Newtonian liquid sprays produced by fan-jet pressure nozzles, operating in the pressure range 500 to nearly 3000 psig (3 450 to 20 680 kPa). The fluids used were water and a water-glycerin mixture. A collection device was constructed and droplets were captured on soot coated microscope slides. Subsequent sizing of the impacted particles with a microscope yielded drop size distribution data of accumulated volume per cent versus diameter. An experimental analysis was performed to relate the nozzle wall shear to the volume median diameter of the spray distribution. A linear correlation was found to exist on a semilog graph; for the Newtonian liquid sprays, it was determined that the volume median diameter could be predicted with: Dd=+8.5183−1.1113logτρQμσ

1979 ◽  
Vol 101 (4) ◽  
pp. 449-455
Author(s):  
W. S. Janna ◽  
J. E. A. John

The drop-size distribution of Bingham liquid sprays was determined by experimentation. Three different highly viscous paints were sprayed with fan-jet airless spray nozzles at pressure ranging from 5 170 to 18 200 kPa. A collection device was constructed to capture a spray sample on microscope slides. Measurement of flattened droplet diameters with a microscope yielded drop-size distribution curves of accumulated volume per cent versus volume median diameter. It was postulated that the wall shear stress existing at the exit plane of the nozzle initiated liquid atomization. A logarithmic correlation was found between shear stress and volume median diameter.


1981 ◽  
Vol 103 (4) ◽  
pp. 402-408
Author(s):  
William S. Janna ◽  
James E. A. John

Measurements were made of the drop-size distributions of water and of paint sprays produced by fan-jet pressure nozzles, operating in the pressure range 900 to nearly 3000 psi (6200–20,680 kPa). A collection device was constructed and droplets were captured on soot-coated and on plain microscope slides. Subsequent sizing of the impacted particles with a microscope yielded drop-size distribution data of accumulated volume percent versus diameter. Data were gathered of water and of paint sprays produced by a fan-jet pressure nozzle-preorifice combination. The effect of the preorifice on drop-size distribution was evaluated.


2020 ◽  
Author(s):  
Martin Fencl ◽  
Michal Dohnal ◽  
Pavel Valtr ◽  
Martin Grabner ◽  
Vojtěch Bareš

Abstract. Opportunistic sensing of rainfall and water vapor using commercial microwave links operated within cellular networks was conceived more than a decade ago. It has since been further investigated in numerous studies predominantly concentrating on the frequency region of 15–40 GHz. This manuscript provides the first evaluation of rainfall and water vapor sensing with microwave links operating at an E band (specifically, 71–76 GHz and 81–86 GHz), which are increasingly updating, and frequently replacing, older communication infrastructure. Attenuation-rainfall relations are investigated theoretically on drop size distribution data. Furthermore, quantitative rainfall estimates from six microwave links, operated within cellular backhaul, are compared with observed rainfall intensities. Finally, the capability to detect water vapor is demonstrated on the longest microwave link measuring 4.86 km in path length. The results show that E-band microwave links are by one order of magnitude more sensitive to rainfall than devices operating in the 15–40 GHz range and are thus able to observe even light rainfalls, a feat practically impossible to achieve previously. The E-band links are, however, substantially more affected by errors related to variable drop size distribution. Water vapor retrieval might be possible from long E band microwave links, nevertheless, the efficient separation of gaseous attenuation from other signal losses will be challenging in practice.


1973 ◽  
Vol 1973 (1) ◽  
pp. 457-465 ◽  
Author(s):  
Vijay K. Stokes ◽  
Andrew C. Harvey

ABSTRACT The oil drop size distribution in oil water mixtures is of importance in the design of separators that make use of settling or enhanced settling as in centrifuges. This paper describes an attempt to identify the parameters that affect the size distribution of drops in mechanically generated emulsions. Oil/water mixtures were made by three different methods. On the basis of the results of these tests, a standard procedure for making mixtures was adopted. This paper presents the results of an extensive series of tests, with three different oils, in which the drop size distributions were measured by a Coulter Counter.


2004 ◽  
Vol 21 (12) ◽  
pp. 1855-1867 ◽  
Author(s):  
Sebastian Schmidt ◽  
Katrin Lehmann ◽  
Manfred Wendisch

Abstract A modified version of the Fast-FSSP (the so-called M-Fast-FSSP) is introduced. It allows minimization of the instrumental broadening of measured cloud drop size distributions caused by laser beam inhomogeneities. This is achieved by applying a new technique based on a postexperiment stepwise reduction of the probe's sampling volume. For monodisperse glass bead samples it is shown that the width of the measured size distribution is considerably reduced when applying this technique, especially for large glass bead diameters. The instrumental broadening may exceed a factor of about 4 for a mean glass bead diameter of 30 μm. The M-Fast-FSSP was applied in two cloud measurement campaigns. For two specific cloud cases, the profile of the width of the measured drop size distribution changes significantly when applying the method.


RSC Advances ◽  
2015 ◽  
Vol 5 (116) ◽  
pp. 95967-95980 ◽  
Author(s):  
Mehdi Asadollahzadeh ◽  
Meisam Torab-Mostaedi ◽  
Shahrokh Shahhosseini ◽  
Ahad Ghaemi

In this study, the maximum entropy principle is used to predict the drop size distributions in a multi-impeller column extractor.


Atmosphere ◽  
2020 ◽  
Vol 11 (6) ◽  
pp. 578 ◽  
Author(s):  
Merhala Thurai ◽  
Viswanathan N. Bringi ◽  
David B. Wolff ◽  
David A. Marks ◽  
Charanjit S. Pabla

Hurricane rainbands are very efficient rain producers, but details on drop size distributions are still lacking. This study focuses on the rainbands of hurricane Dorian as they traversed the densely instrumented NASA precipitation-research facility at Wallops Island, VA, over a period of 8 h. Drop size distribution (DSD) was measured using a high-resolution meteorological particle spectrometer (MPS) and 2D video disdrometer, both located inside a double-fence wind shield. The shape of the DSD was examined using double-moment normalization, and compared with similar shapes from semiarid and subtropical sites. Dorian rainbands had a superexponential shape at small normalized diameter values similar to those of the other sites. NASA’s S-band polarimetric radar performed range height-indicator (RHI) scans over the disdrometer site, showing some remarkable signatures in the melting layer (bright-band reflectivity peaks of 55 dBZ, a dip in the copolar correlation to 0.85 indicative of 12–15 mm wet snow, and a staggering reflectivity gradient above the 0 °C level of −10 dB/km, indicative of heavy aggregation). In the rain layer at heights < 2.5 km, polarimetric signatures indicated drop break-up as the dominant process, but drops as large as 5 mm were detected during the intense bright-band period.


2021 ◽  
Author(s):  
Remko Uijlenhoet

&lt;p&gt;It has been stated that &quot;the study of drop-size distributions, with its roots in both land-surface processes [e.g. interception, erosion, infiltration and surface runoff] and atmospheric remote sensing [e.g. radar meteorology], provides an important element to an integrated program of hydrometeorological research&quot; (Smith, 1993). Although raindrop size distributions have been studied from a scientific perspective since the early 20th century, it was not until the mid-1990s that researchers realized that all parameterizations for the drop size distribution published until then could be summarized in the form of a scaling law, which provided &quot;a general phenomenological formulation for drop size distribution&quot; (Sempere Torres et al., 1994). The main implication of the proposed expression is that the integral rainfall variables (such as rain rate and radar reflectivity) are related by power laws, in agreement with experimental evidence. The proposed formulation naturally leads to a general methodology for scaling all raindrop size data in a unique plot, which yields more robust fits of the drop size distribution. Here, we provide a statistical interpretation of the law&amp;#8217;s scaling exponents in terms of different modes of control on the space-time variability of drop size distributions, namely size-control vs. number-control, inspired by the work of Smith and De Veaux (1994). Also, an attempt will be made toward interpreting the values of the scaling exponents and the shape of the scaled drop size distribution in terms of the underlying (micro)physical processes.&lt;/p&gt;&lt;p&gt;REFERENCES&lt;/p&gt;&lt;p&gt;Smith, J. A., 1993: Precipitation. In Maidment, D. R., editor, Handbook of Hydrology, pages 3.1&amp;#8211;3.47. McGraw-Hill, New York.&lt;/p&gt;&lt;p&gt;Sempere Torres, D., J.M. Porr&amp;#224;, and J.-D. Creutin, 1994: A general formulation for raindrop size distribution. J. Appl. Meteor., 33, 1494&amp;#8211;1502.&lt;/p&gt;&lt;p&gt;Smith, J.A. and R.D. De Veaux, 1994: A stochastic model relating rainfall intensity to raindrop processes. Water Resour. Res., 30, 651&amp;#8211;664.&lt;/p&gt;


1957 ◽  
Vol 14 (1) ◽  
pp. 55-59 ◽  
Author(s):  
Ralph G. Eldridge

Abstract Through the analysis of infrared transmittance of a natural cloud, its drop-size distribution can be inferred. This technique has been used to measure and analyze ten cloud situations on Mount Washington. These clouds show drop-size distributions that are bimodal in character. In all the distributions, a large number of small droplets is inferred. To test the synthesized distributions in another region of the spectrum, the visual range was computed. This determination of the visual range is in agreement with the observed visibilities.


2011 ◽  
Vol 11 (19) ◽  
pp. 10205-10218 ◽  
Author(s):  
C. Emersic ◽  
P. J. Connolly

Abstract. Collision-induced water drop breakup in a vertical wind tunnel was observed using a high speed camera for interactions between larger drop sizes (up to 7 mm diameter) than have previously been experimentally observed. Three distinct collisional breakup types were observed and the drop size distributions from each were analysed for comparison with predictions of fragment distributions from larger drops by two sets of established breakup parameterisations. The observations showed some similarities with both parameterisations but also some marked differences for the breakup types that could be compared, particularly for fragments 1 mm and smaller. Modifications to the parameterisations are suggested and examined. Presented is also currently the largest dataset of bag breakup distributions observed. Differences between this and other experimental research studies and modelling parameterisations, and the associated implications for interpreting results are discussed. Additionally, the stochastic coalescence and breakup equation was solved computationally using a breakup parameterisation, and the evolving drop-size distribution for a range of initial conditions was examined. Initial cloud liquid water content was found to have the greatest influence on the resulting distribution, whereas initial drop number was found to have relatively little influence. This may have implications when considering the effect of aerosol on cloud evolution, raindrop formation and resulting drop size distributions. Calculations presented show that, using an ideal initial cloud drop-size distribution, ~1–3% of the total fragments are contributed from collisional breakup between drops of 4 and 6 mm.


Sign in / Sign up

Export Citation Format

Share Document