Photographic Study on Bubble Motion in Subcooled Pool Boiling

Author(s):  
Tomio Okawa ◽  
Takahiro Harada ◽  
Yuta Kotsusa

Using a static contact angle of a vertical heated wall as a main experimental parameter, a photographic study was carried out to elucidate the mechanisms to determine the vapor bubble dynamics during subcooled pool boiling. The test fluid was distilled water and the experiments were performed under the atmospheric pressure; liquid subcooling was set to around 5 K. To enable clear observation of bubble behavior with a high speed camera, the experiments were conducted in an isolated bubble regime near the onset of nucleate boiling. Distinctly different bubble behaviors were observed on hydrophobic and hydrophilic surfaces: the bubbles were adhered to the surface for a long period of time when the contact angle was large while lifted-off the surface within a short period of time after the nucleation when the contact angle was small. Since buoyancy does not remove the bubble from the vertical surface, the mechanisms of bubble lift-off were investigated. It was indicated that the change in bubble shape induced by the surface tension force, unsteady growth force, and local liquid flow induced by heterogeneous condensation around the bubble are considered to promote the bubble lift-off while the surface tension force acting on the three-phase common line prevented the lift-off. Effects of the surface wettability on the lift-off bubble diameter, the elapsed time from the nucleation at the lift-off, and the condensation rate after the lift-off were also investigated.

Author(s):  
Tomio Okawa ◽  
Takahiro Harada ◽  
Yuta Koutsusa

Using a static contact angle as a main experimental parameter, photographic study was carried out to investigate the dynamics of vapor bubbles during subcooled pool boiling on a vertical heated surface. Test fluid was distilled water and the experiments were performed under the atmospheric pressure; liquid subcooling was set to around 5 K. To enable clear observation of bubble behavior with a high speed camera, the experiments were conducted in an isolated bubble regime near the onset of nucleate boiling. Distinctly different bubble behaviors were observed on hydrophobic and hydrophilic surfaces: the bubbles were adhered to the surface for a long period of time when the contact angle was large while lifted off the surface within a short period of time after the nucleation when the contact angle was small. Since buoyancy does not remove the bubble from a vertical surface, mechanisms of lift-off were investigated. It was shown that the change in bubble shape induced by the surface tension force, unsteady growth force and local liquid flow induced by heterogeneous condensation around the bubble are considered to promote the bubble lift-off and the surface tension force acting on the three-phase common line prevents the lift-off. Dependences of bubble size and time at lift-off and the condensation rate on the surface wettability were also investigated.


Author(s):  
Abhijit Mukherjee ◽  
Satish G. Kandlikar

Nucleate pool boiling at low heat flux is typically characterized by cyclic growth and departure of single vapor bubbles from the heated wall. It has been experimentally observed that the contact angle at the bubble base varies during the ebullition cycle. In the present numerical study, dynamic advancing and receding contact angles obtained from experimental observations are specified at the base of a vapor bubble growing on a wall. The complete Navier-Stokes equations are solved and the liquid-vapor interface is captured using the level-set technique. The effect of dynamic contact angle on the bubble dynamics and vapor removal rate are compared to results obtained with static contact angle. The results show that bubble base exhibits a slip/stick behavior with dynamic contact angle though the overall effect on the vapor removal rate is small. Higher advancing contact angle is found to increase the vapor removal rate.


2012 ◽  
Vol 550-553 ◽  
pp. 2913-2916 ◽  
Author(s):  
Jin Liang Tao ◽  
Xin Liang Wang ◽  
Pei Hua Shi ◽  
Xiao Ping Shi

In this paper, a new porous coating was formed directly on the surface of titanium metal via anodic oxidation. And by the SEM, the morphology of the coating, which is composed of well-ordered perpendicular nanotubes, was characterized. Moreover, taking deionized water as the test fluid, a visualization study of the coating on its pool boiling heat transfer performance was made. The results demonstrated that compared with the smooth surface, the nucleate boiling heat transfer coefficient can increase 3 times while the nucleate boiling super heat was reduced 30%.


Author(s):  
Vijaykumar Sathyamurthi ◽  
Debjyoti Banerjee

Heat transfer in subcooled pool boiling on nano-textured surfaces is reported in this study. Silicon wafers coated with Multiwalled Carbon Nanotubes (MWCNT) forests 9 microns (Type-A), and 25 microns (Type-B) in height and 8–15 nm in diameter with a randomized pitch of 16–30 nm, form the test surfaces. The test fluid is a fluoroinert (PF-5060, Manufacturer: 3M Co.) with a boiling point of 56°C. The test rig is of the constant heat flux type. Heat transfer enhancement of approximately 1.3 to 32% is observed in the nucleate boiling regime for Type-A at subcooling levels of 20°C. Type-B CNT shows an enhancement of about 13–30% in the nucleate boiling regime for 20°C subcooling. Digital images acquired during the tests show increased nucleation occurring on surfaces coated with MWCNT. Potential factors that could explain the observed heat transfer enhancement are: the enhanced surface area (nano-fin effect), disruption of the “microlayer” region in nucleate boiling, an increase in the size of cold-spots and the high thermal conductivity of MWCNT.


1985 ◽  
Vol 107 (2) ◽  
pp. 369-376 ◽  
Author(s):  
R. L. Webb ◽  
T. M. Rudy ◽  
M. A. Kedzierski

A theoretical model is developed for prediction of the condensation coefficient on horizontal integral-fin tubes for both high and low surface tension fluids. The model includes the effects of surface tension on film drainage and on condensate retention between the fins. First, the fraction of the tube circumference that is flooded with condensate is calculated. Typically, the condensation coefficient in the flooded region is negligible compared to that of the unflooded region. Then the condensation coefficient on the unflooded portion is calculated, assuming that surface tension force drains the condensate from the fins. The model is used to predict the R-11 condensation coefficient on horizontal, integral-fin tubes having 748, 1024, and 1378 fpm. The predicted values are within ±20 percent of the experimental values.


2012 ◽  
Vol 134 (7) ◽  
Author(s):  
Ho Seon Ahn ◽  
Joonwon Kim ◽  
Moo Hwan Kim

Dynamic wetting behaviors of water droplet on the modified surface were investigated experimentally. Dynamic contact angles were measured as a characterization method to explain the extraordinary pool boiling critical heat flux (CHF) enhancement on the zirconium surface by anodic oxidation modification. The sample surface is rectangular zirconium alloy plates (20 × 25 × 0.7 mm), and 12 μl of deionized water droplets were fallen from 40 mm of height over the surface. Dynamic wetting movement of water on the surface showed different characteristics depending on static contact angle (49.3 deg–0 deg) and surface temperature (120 °C–280 °C). Compared with bare surface, wettable and spreading surface had no-receding contact angle jump and seemed stable evaporating meniscus of liquid droplet in dynamic wetting condition on hot surface. This phenomenon could be explained by the interaction between the evaporation recoil and the surface tension forces. The surface tension force increased by micro/nanostructure of the modified zirconium surface suppresses the vapor recoil force by evaporation which makes the water layer unstable on the heated surface. Thus, such increased surface force could sustain the water layer stable in pool boiling CHF condition so that the extraordinary CHF enhancement could be possible.


Author(s):  
Jung-Yeul Jung ◽  
Young Won Kim ◽  
Jung Yul Yoo

It is well known that the liquid and the nanoparticles in an evaporating colloid droplet on the hydrophilic surface move radially outward for the contact line to maintain its position. However, the motion of micro-/nano-particles in an evaporating di-dispersed colloid droplet has not been reported to date. In this study, an experiment on an evaporating di-dispersed colloid droplet on the hydrophilic surface is carried out. It is found that nano-particles move radially outward and remain at the contact line while micro-particles move inward toward the center of the droplet. Further the mechanism of the micro-particles moving toward the center of the droplet is found to be due to the surface tension force of the liquid.


2009 ◽  
Vol 131 (7) ◽  
Author(s):  
V. Sathyamurthi ◽  
H-S. Ahn ◽  
D. Banerjee ◽  
S. C. Lau

Pool boiling experiments were conducted with three horizontal, flat, silicon surfaces, two of which were coated with vertically aligned multiwalled carbon nanotubes (MWCNTs). The two wafers were coated with MWCNT of two different thicknesses: 9 μm (Type-A) and 25 μm (Type-B). Experiments were conducted for the nucleate boiling and film boiling regimes for saturated and subcooled conditions with liquid subcooling of 0–30°C using a dielectric fluorocarbon liquid (PF-5060) as test fluid. The pool boiling heat flux data obtained from the bare silicon test surface were used as a base line for all heat transfer comparisons. Type-B MWCNT coatings enhanced the critical heat flux (CHF) in saturated nucleate boiling by 58%. The heat flux at the Leidenfrost point was enhanced by a maximum of ∼150% (i.e., 2.5 times) at 10°C subcooling. Type-A MWCNT enhanced the CHF in nucleate boiling by as much as 62%. Both Type-A MWCNT and bare silicon test surfaces showed similar heat transfer rates (within the bounds of experimental uncertainty) in film boiling. The Leidenfrost points on the boiling curve for Type-A MWCNT occurred at higher wall superheats. The percentage enhancements in the value of heat flux at the CHF condition decreased with an increase in liquid subcooling. However the enhancement in heat flux at the Leidenfrost points for the nanotube coated surfaces increased with liquid subcooling. Significantly higher bubble nucleation rates were observed for both nanotube coated surfaces.


Author(s):  
Eiji Ishii ◽  
Taisuke Sugii

Predicting the spreading behavior of droplets on a wall is important for designing micro/nano devices used for reagent dispensation in micro-electro-mechanical systems, printing processes of ink-jet printers, and condensation of droplets on a wall during spray forming in atomizers. Particle methods are useful for simulating the behavior of many droplets generated by micro/nano devices in practical computational time; the motion of each droplet is simulated using a group of particles, and no particles are assigned in the gas region if interactions between the droplets and gas are weak. Furthermore, liquid-gas interfaces obtained from the particle method remain sharp by using the Lagrangian description. However, conventional surface tension models used in the particle methods are used for predicting the static contact angle at a three-phase interface, not for predicting the dynamic contact angle. The dynamic contact angle defines the shape of a spreading droplet on a wall. We previously developed a surface tension model using inter-particle force in the particle method; the static contact angle of droplets on the wall was verified at various contact angles, and the heights of droplets agreed well with those obtained theoretically. In this study, we applied our surface tension model to the simulation of a spreading droplet on a wall. The simulated dynamic contact angles for some Weber numbers were compared with those measured by Šikalo et al, and they agreed well. Our surface tension model was useful for simulating droplet motion under static and dynamic conditions.


Sign in / Sign up

Export Citation Format

Share Document