Confinement Effects on FKE-774 Critical Heat Flux in Buoyancy-Driven Microgap Channels

Author(s):  
Karl J. L. Geisler ◽  
Shweta Natarajan

Critical heat flux (CHF) of the fluoroketone fluid FKE-774 in vertical microgap channels is explored, with a focus on submillimeter spacings. Experiments were conducted using a 20 mm × 20 mm heated aluminum surface. Microgap channel spacings were decreased down to 0.3 mm, providing channel aspect ratios (height/spacing) as high as 67. In the limit where channel spacing is large, CHF was found to be 140 kW/m2 for saturated boiling at atmospheric pressure. A reduction in CHF of 55% was observed for the largest channel aspect ratio investigated. Results for degradation of the CHF limit with decreasing microgap spacing are compared to a correlation available in the literature and show a roughly hyperbolic dependence on channel aspect ratio (height/spacing) for aspect ratios larger than 10.

1996 ◽  
Vol 118 (1) ◽  
pp. 21-26 ◽  
Author(s):  
David Copeland

Experimental measurements of multiple nozzle submerged jet array impingement single-phase and boiling heat transfer were made using FC-72 and 1 cm square copper pin fin arrays, having equal width and spacing of 0.1 and 0.2 mm, with aspect ratios from 1 to 5. Arrays of 25 and 100 nozzles were used, with diameters of 0.25 to 1.0 mm providing nozzle area from 5 to 20 mm2 (5 to 20% of the heat source base area). Flow rates of 2.5 to 10 cm3/s (0.15 to 0.6 l/min) were studied, with nozzle velocities from 0.125 to 2 m/s. Single nozzles and smooth surfaces were also evaluated for comparison. Single-phase heat transfer coefficients (based on planform area) from 2.4 to 49.3 kW/m2 K were measured, while critical heat flux varied from 45 to 395 W/cm2. Correlations of the single-phase heat transfer coefficient and critical heat flux as functions of pin fin dimensions, number of nozzles, nozzle area and liquid flow rate are provided.


Author(s):  
A. E. Bergles

During the past 20 years, there has been intense worldwide interest in microchannel heat exchangers, particularly for cooling of microelectronic components. Saturated boiling of the coolant is usually indicated in order to accommodate high heat fluxes and to have uniformity of temperature. However, boiling is accompanied by several instabilities, the most severe of which can sharply limit the maximum, or critical, heat flux. These stability phenomena are reviewed, and recent studies will be discussed. Elevation of the critical heat flux will be discussed within the context of heat transfer enhancement. Means to improve the stability of boiling and the enhancement of boiling heat transfer, in general, are discussed.


Entropy ◽  
2021 ◽  
Vol 23 (11) ◽  
pp. 1528
Author(s):  
Wenlong Li ◽  
Zhihui Xie ◽  
Kun Xi ◽  
Shaojun Xia ◽  
Yanlin Ge

A model of rectangular microchannel heat sink (MCHS) with porous medium (PM) is developed. Aspect ratio of heat sink (HS) cell and length-width ratio of HS are optimized by numerical simulation method for entropy generation minimization (EGM) according to constructal theory. The effects of inlet Reynolds number (Re) of coolant, heat flux on bottom, porosity and volume proportion of PM on dimensionless entropy generation rate (DEGR) are analyzed. From the results, there are optimal aspect ratios to minimize DEGR. Given the initial condition, DEGR is 33.10% lower than its initial value after the aspect ratio is optimized. With the increase of Re, the optimal aspect ratio declines, and the minimum DEGR drops as well. DEGR gets larger and the optimal aspect ratio remains constant with the increasing of heat flux on bottom. For the different volume proportion of PM, the optimal aspect ratios are diverse, but the minimum DEGR almost stays unchanged. The twice minimized DEGR, which results from aspect ratio and length-width ratio optimized simultaneously, is 10.70% lower than the once minimized DEGR. For a rectangular bottom, a lower DEGR can be reached by choosing the proper direction of fluid flow.


1964 ◽  
Vol 86 (1) ◽  
pp. 68-74 ◽  
Author(s):  
G. C. Vliet ◽  
G. Leppert

Empirical data are presented which show the effects of diameter, water velocity, and subcooling on the critical heat flux from an electrically heated, cylindrical lube or wire. The maximum flux which can be accommodated in subcooled nucleate boiling is found to vary directly with the water velocity and subcooling and inversely with a fractional power of the heater diameter. The exponent which describes the diameter dependence is itself a function of both velocity and subcooling. Measurements of the critical flux are reported for water at atmospheric pressure over a range of subcooling from 3 to 100 deg F, velocity from 0.5 to 11 ft/sec, and heater diameter from 0.010 to 0.189 in. Visual and photographic observations indicate a marked effect of subcooling on the flow mechanism near the critical heat flux. High subcooling prevents the formation of the vapor cavity which was described in the previous paper [1] for nearly saturated water, although the failure of nucleate boiling still occurs at the rear of the cylinder and is accompanied by a concentration of vapor in that region.


Author(s):  
Mosfequr Rahman ◽  
Charles Walker ◽  
Gustavo Molina ◽  
Valentin Soloiu

Natural convection in rectangular enclosures is found in many real-world engineering applications. Included in these applications are the energy efficient design of buildings, operation and safety of nuclear reactors, solar collector design, passive energy storage, heat transfer across multi-pane windows, thermo-electric refrigeration and heating devices, and the design-for-mitigation of optical distortion in large-scale laser systems. A common industrial application of natural convection is free air cooling without the aid of fans and can happen on small scales such as computer chips to large scale process equipment. The enclosure phenomena can loosely be organized into two large classes: (1) horizontal enclosures heated from below and (2) vertical enclosures heated from the side. In addition to temperature gradient convection strength within the enclosure can vary due to the existence of heat sources with different strength. Numerical simulations are conducted for free convective flow of air with or without internal heat generation in two-dimensional rectangular enclosures of different aspect ratios. The objective of this numerical study is to investigate the effects of external temperature gradient, internal heat generation and aspect ratio (AR) of enclosure (ratio of the length of the isothermal walls to their separation distance), in free convective laminar flow of a fluid. Two-dimensional rectangular enclosures of different aspect ratio (1, 2, 4, 6, 8, and 10) with two adiabatic side walls and isothermal bottom (hot) and top (cold) walls are considered for the first configuration. Whereas for the second configuration, two adiabatic top and bottom walls, isothermal left side (cold) and right side (hot) walls are considered. Two principal parameters considered for the flow of fluid are the external Rayleigh number, RaE, which represents the effect due to the differential heating of the isothermal walls, and the internal Rayleigh number, RaI, which represents the strength of the internal heat generation. The effect of external temperature gradient and aspect ratio on natural convection has been observed by varying the value of external Rayleigh number (RaE) equal to 2×104, 2×105, and 2×106 and keeping the internal Rayleigh number constant (RaI = 2×105). Similarly, the effect of internal heat generation and aspect ratio on natural convection has been observed by varying the value of internal Rayleigh number (RaI) equal to 2×104, 2×105, and 2×106 and keeping the external Rayleigh number constant (RaE = 2×105). Significant changes in flow patterns and isotherms have been observed for all cases. Also the variation of average heat flux ratio (convective heat flux/corresponding conduction heat flux) along the hot and cold walls, and the convection strength have been calculated for all cases. It is found that the aspect ratio has a significant effect in fluid flow and heat transfer in the enclosures. The average heat flux ratio and the strength of convection increase with aspect ratio as the enclosure shape changes square (AR = 1) to shallow (AR > 1).