Author(s):  
Leandro Oliveira Salviano ◽  
Elóy Esteves Gasparin ◽  
Vitor Cesar N. Mattos ◽  
Bruno Barbizan ◽  
Fábio Saltara ◽  
...  

Author(s):  
P A Eynon ◽  
A Whitfield

The design of low-solidity diffuser vanes and the effect on the performance of a turbo-charger compressor is discussed. The effect of vane number and turning angle was investigated while maintaining a basic design with a solidity of 0.69 and a leading edge angle of 75°. This large leading edge angle was specifically chosen so that the vane would be aligned with the low flowrates close to surge. Tests were initially conducted with six, eight and ten vanes and a turning angle of 10°. Based on these results the ten-vane design was selected for further investigation with 15 and 20° of vane turning; this led to vane exit angles of 60 and 55° respectively. All results are compared with those obtained with the standard vaneless diffuser configuration and it was shown that all designs increased and shifted the peak pressure ratio to reduced flowrates. The peak efficiency was reduced relative to that obtained with the vaneless diffuser. Despite the low-solidity configuration none of the vane designs provided a broad operating range without the use of a variable geometry configuration. This was attributed to the selection of a large leading edge vane angle.


Author(s):  
Zitian Niu ◽  
Zhenzhong Sun ◽  
Baotong Wang ◽  
Xinqian Zheng

Abstract Rotating stall is an important unstable flow phenomenon that leads to performance degradation and limits the stability boundary in centrifugal compressors. The volute is one of the sources to induce the non-axisymmetric flow in a centrifugal compressor, which has an important effect on the performance of compressors. However, the influence of volute on rotating stall is not clear. Therefore, the effects of volute on rotating stall by experimental and numerical simulation have been explored in this paper. It’s shown that one rotating stall cell generates in a specific location and disappears in another specific location of the vaneless diffuser as a result of the distorted flow field caused by the volute. Also, the cells cannot stably rotate in a whole circle. The frequency related to rotating stall captured in the experiment is 43.9% of the impeller passing frequency (IPF), while it is 44.7% of IPF captured by three-dimensional unsteady numerical simulation, which proves the accuracy of the numerical method in this study. The numerical simulation further reveals that the stall cell initialized in a specific location can be split into several cells during the evolution process. The reason for this is that the blockage in the vaneless diffuser induced by rotating stall is weakened by the mainstream from the impeller exit to make one initialized cell disperse into several ones. The volute has an important influence on the generation and evolution process of the rotating stall cells of compressors. By optimizing volute geometry to reduce the distortion of the flow field, it is expected that rotating stall can be weakened or suppressed, which is helpful to widen the operating range of centrifugal compressors.


2001 ◽  
Author(s):  
Tarek Mekhail ◽  
Zhang Li ◽  
Du Zhaohui ◽  
Willem Jansen ◽  
Chen Hanping

Abstract The PIV (Particle Image Velocimetry) technology is a brand-new technique of measuring velocity. It started in the 1980’s with the development of high-speed photography and the image processing technique of computers. This article deals with PIV applied to the study of unsteady impeller-vaneless diffuser interaction in centrifugal fen. Experiments were carried out at The Turbomachinery Laboratory of Shanghai Jiaotong University. The test rig consists of a centrifugal, shrouded impeller, diffuser and volute casing all made of plexiglass. A series of performance measurements were carried out at different speeds and different vaneless diffuser widths. PIV measurements were applied to measure the unsteady flow at the exit part of the impeller and the inlet part of the diffuser for the case of the same width vaneless diffuser. The absolute flow field is measured at medium flow rate and at maximum flow rate. It is informative to capture the whole flow field at the same instant of time, and it might be more revealing to observe the unstable flow in real time.


Author(s):  
Kiyotaka Hiradate ◽  
Hiromi Kobayashi ◽  
Takahiro Nishioka

This study experimentally and numerically investigates the effect of application of curvilinear element blades to fully-shrouded centrifugal compressor impeller on the performance of centrifugal compressor stage. Design suction flow coefficient of compressor stage investigated in this study is 0.125. The design guidelines for the curvilinear element blades which had been previously developed was applied to line element blades of a reference conventional impeller and a new centrifugal compressor impeller with curvilinear element blades was designed. Numerical calculations and performance tests of two centrifugal compressor stages with the conventional impeller and the new one were conducted to investigate the effectiveness of application of the curvilinear element blades and compare the inner flowfield in details. Despite 0.5% deterioration of the impeller efficiency, it was confirmed from the performance test results that the compressor stage with the new impeller achieved 1.7% higher stage efficiency at the design point than that with the conventional one. Moreover, it was confirmed that the compressor stage with the new impeller achieved almost the same off-design performance as that of the conventional stage. From results of the numerical calculations and the experiments, it is considered that this efficiency improvement of the new stage was achieved by suppression of the secondary flows in the impeller due to application of negative tangential lean. The suppression of the secondary flows in the impeller achieved uniformalized flow distribution at the impeller outlet and increased the static pressure recovery coefficient in the vaneless diffuser. As a result, it is thought that the total pressure loss was reduced downstream of the vaneless diffuser outlet in the new stage.


Sign in / Sign up

Export Citation Format

Share Document