Thermo-Fluid Dynamic Design Exploration of a Double Pipe Heat Exchanger

Author(s):  
Tomohiro Hirano ◽  
Mitsuo Yoshimura ◽  
Koji Shimoyama ◽  
Atsuki Komiya

Abstract Toward a practical application of the additive manufacturing (AM), this study proposes a shape optimization approach for the cross-sectional shape of the inner pipe of a counter-flow double pipe heat exchanger. The cross-sectional shape of the inner pipe is expressed by an algebraic expression with a small number of parameters, and their heat transfer performance is evaluated by a commercial Computational Fluid Dynamics (CFD) solver. The optimization is conducted by the Non-Dominated Sorting Genetic Algorithm II (NSGA-II) assisted by the Kriging surrogate model, and the NSGA-II finds the optimal cross-sectional shape with many protrusions around the perimeter of the inner channel to improve the heat transfer performance. In this study, heat transfer performance is evaluated from the temperature drop at the outlet of the high-temperature fluid. Through the comparison of two cross-sectional shapes with the same heat transfer surface area — average temperature at the outlet of the optimal high-temperature channel is 324.58 K while average temperature at the outlet of a circular high-temperature channel with the same area as the optimal channel is 331.93 K, it is revealed that the number of protrusions plays important roles which contribute not only to increase heat transfer area but also to improve heat transfer performance.

2020 ◽  
Vol 145 ◽  
pp. 1049-1060 ◽  
Author(s):  
Chao Li ◽  
Yanling Guan ◽  
Ruitao Yang ◽  
Xiong Lu ◽  
Wenxue Xiong ◽  
...  

2019 ◽  
Vol 8 (4) ◽  
pp. 5892-5898

Nanofluids have good potential in enhancing the heat transfer performance of conventional fluids. In the present paper, the heat transfer performance of Fe3O4 and its Hybrid mixture with Fe3O4 and SiC nanoparticles in the volume ratio of 50:50 in 20:80 Ethylene Glycol (EG) –Water as base fluid are determined experimentally and the results are compared with that of the base fluid. The volume concentration range of nanoparticles considered in the analysis is 0.01% to 0.08%. The experiment is carried under turbulent flow conditions with Reynolds number ranging from 5000 to 20000 in a Double Pipe Heat Exchanger (DPHE) with U-bend. Results indicate that the thermal conductivity of hybrid nanofluid is higher by 16.19% and its viscosity is lower by 11.6% compared to Fe3O4 /20:80 EG-Water nanofluid at an operating temperature of 45°C. The heat transfer coefficient and overall performance of hybrid nanofluid are better than Fe3O4 /20:80 EG-Water nanofluid. The overall performance of Hybrid nanofluid is 27.75% better than that of Fe3O4 /20:80 EG-Water nanofluid.


2012 ◽  
Vol 550-553 ◽  
pp. 3024-3028
Author(s):  
Yi Ning Wang ◽  
Qun Hui Lu ◽  
Yang Yan Zheng ◽  
Biao Yuan

In this article, simulation analysis has been performed for the flow and heat transfer performance of spiral flow double-pipe heat exchanger using finite volume method, respectively for the relationship between Nu and the average shear force on inner pipe outer wall at different turbulent flow Re with different radial offset of inlet and outlet pipes and different spacing of inlet and outlet pipes. The results show that, as compared with an ordinary double-pipe heat exchanger, in a spiral flow double-pipe heat exchanger, both inner pipe convective heat exchange coefficient and inner pipe wall surface shear force are lower, with the magnitude of reduction related to a number of factors such as radial offset of inlet and outlet pipes and Re. The study in this article has provided theoretical basis for further engineering application of spiral flow double-pipe heat exchangers.