The Development of Turbine Exit Flow in a Swan-Necked Inter-Stage Diffuser

Author(s):  
R. J. Miller ◽  
R. W. Moss ◽  
R. W. Ainsworth ◽  
N. W. Harvey

This paper describes both the migration and dissipation of flow phenomena downstream of a transonic high-pressure turbine stage. The geometry of the HP stage exit duct considered is a swan-necked diffuser similar to those likely to be used in future engine designs. The paper contains results both from an experimental programme in a turbine test facility and from numerical predictions. Experimental data was acquired using three fast-response aerodynamic probes capable of measuring Mach number, whirl angle, pitch angle, total pressure and static pressure. The probes were used to make time-resolved area traverses at two axial locations downstream of the rotor trailing edge. A 3D time-unsteady viscous Navier-Stokes solver was used for the numerical predictions. The unsteady exit flow from a turbine stage is formed from rotor-dependent phenomena (such as the rotor wake, the rotor trailing edge recompression shock, the tip-leakage flow and the hub secondary flow) and vane-rotor interaction dependant phenomena. This paper describes the time-resolved behaviour and three-dimensional migration paths of both of these phenomena as they convect downstream. It is shown that the inlet flow to a downstream vane is dominated by two corotating vortices, the first caused by the rotor tip-leakage flow and the second by the rotor hub secondary flow. At the inlet plane of the downstream vane the wake is extremely weak and the radial pressure gradient is shown to have caused the majority of the high loss wake fluid to be located between the mid-height of the passage and the casing wall. The structure of the flow indicates that between a high pressure stage and a downstream vane simple two-dimensional blade row interaction does not occur. The results presented in this paper indicate that the presence of an upstream stage is likely to significantly alter the structure of the secondary flow within a downstream vane. The paper also shows that vane-rotor interaction within the upstream stage causes a 10° circumferential variation in the inlet flow angle of the 2nd stage vane.

2003 ◽  
Vol 125 (1) ◽  
pp. 1-13 ◽  
Author(s):  
R. J. Miller ◽  
R. W. Moss ◽  
R. W. Ainsworth ◽  
C. K. Horwood

This paper describes the time-varying aerodynamic interaction mechanisms that have been observed within a transonic high-pressure turbine stage; these are inferred from the time-resolved behavior of the rotor exit flow field. It contains results both from an experimental program in a turbine test facility and from numerical predictions. Experimental data was acquired using a fast-response aerodynamic probe capable of measuring Mach number, whirl angle, pitch angle, total pressure, and static pressure. A 3-D time-unsteady viscous Navier-Stokes solver was used for the numerical predictions. The unsteady rotor exit flowfield is formed from a combination of four flow phenomena: the rotor wake, the rotor trailing edge recompression shock, the tip-leakage flow, and the hub secondary flow. This paper describes the time-resolved behavior of each phenomenon and discusses the interaction mechanisms from which each originates. Two significant vane periodic changes (equivalent to a time-varying flow in the frame of reference of the rotor) in the rotor exit flowfield are identified. The first is a severe vane periodic fluctuation in flow conditions close to the hub wall and the second is a smaller vane periodic fluctuation occurring at equal strength over the entire blade span. These two regions of periodically varying flow are shown to be caused by two groups of interaction mechanisms. The first is thought to be caused by the interaction between the wake and secondary flow of the vane with the downstream rotor; and the second is thought to be caused by a combination of the interaction of the vane trailing edge recompression shock with the rotor, and the interaction between the vane and rotor potential fields.


Author(s):  
Kai Zhou ◽  
Chao Zhou

In an unshrouded high-pressure turbine, tip leakage flow results in a loss of efficiency. In this paper, the aerodynamic performance of the tip leakage flow is investigated in a turbine stage by numerical methods. A flat tip and a closed squealer tip combined with a suction side winglet are used for the rotor tips, and the two turbines are named as ‘Flat Configuration’ and ‘Winglet Configuration’. The ability of the CFD methods in predicting the unsteady flow and the tip leakage flow is validated. The steady calculations using a mixing plane between the stator and the rotor are presented first. Then, the unsteady flows of the turbine stage with a flat rotor tip and a winglet rotor tip are simulated by solving Unsteady Reynolds-Averaged Navier-Stokes (URANS) equations. Compared with the ‘Flat Configuration’, the ‘Winglet Configuration’ reduces the size of the passage vortex and the tip leakage vortex. A surprising observation is that although the ‘Winglet Configuration’ reduces the size of the tip leakage vortex, its maximum swirl strength of the tip leakage vortex is about 40% higher than that for the ‘Flat Configuration’. The steady calculation shows that the entropy generation for the turbine stage is 12.1% lower with the ‘Winglet Configuration’ than that with the ‘Flat Configuration’. The mixed-out entropy predicted in the unsteady calculation is higher than that of the steady calculation for both tips. The stator casing passage vortex has a periodic effect on the vortex near the tip gap of the rotor. The unsteady interaction of the vortices seems to be beneficial in terms of the loss. As a result, the ‘Winglet Configuration’ produces 9.4% less entropy than the ‘Flat Configuration’, which is lower than that in the case of the steady calculation.


2020 ◽  
Vol 37 (4) ◽  
pp. 399-411
Author(s):  
Zhihua Zhou ◽  
Shaowen Chen ◽  
Songtao Wang

AbstractA new geometry parametric method of winglet-cavity tip has been introduced in the optimization procedure based on three-dimensional steady CFD numerical calculation and analysis. Firstly, the reliability of numerical method and grid independency are studied. Then an aerodynamic optimization is performed in an unshrouded axial high pressure turbine with winglet-cavity tip. The optimum winglet-cavity tip has higher turbine stage efficiency and smaller tip leakage mass flow rate than the cavity tip and flat tip. Compared with the results of cavity tip, the effects of the optimum winglet-cavity tip indicate that the stage efficiency is improved effectively by 0.41% with less reduction of tip leakage mass flow rate. The variation of turbine stage efficiency with tip gap states that the optimum winglet-cavity tip obtains the smallest efficiency change rate ∆η/(∆τ/H). For the optimum winglet-cavity tip, the endwall flow and blade tip leakage flow pattern are used to analysis the physical mechanical of losses. In addition, the effects of pressure-side winglet and suction-side winglet are analyzed respectively by the deformation of the optimum winglet-cavity tip. The numerical results show that the pressure-side winglet reduces the tip leakage flow effectively, and the suction-side winglet shows a great improvement on the turbine stage efficiency.


Author(s):  
Victor Opilat ◽  
Joerg R. Seume

The exhaust diffusers studied in this paper are installed behind the last turbine stage of gas turbines, including those used in combined cycle power plants. For the design of efficient diffusers, the effects caused by the last turbine stage need to be taken into account. In the present paper, results are presented to estimate the performance of a diffuser operating under a variation of multiple modelling parameters: tip leakage flow, the swirl, and the rotating blade wakes. To provide a better understanding of the flow parameters, a test facility with a turbine stage simulator is used to model these flow effects and an optical endoscopic planar measurement technique based upon Particle Image Velocimetry (PIV) is applied. The pressure recovery is estimated for various turbine conditions using a variety of relevant parameters. Within a range of conditions, a PIV study is performed to try to understand the typical flow phenomena which influence the performance of axial diffusers. The rise of turbulent energy in the inlet flow positively affects the diffuser performance. A small positive swirl angle in the inlet flow (behind the rotating bladed wheel in experiments) has a stabilizing effect on the diffuser. The tip leakage flow from the last turbine stage can also positively affect the pressure recovery in the diffuser.


Author(s):  
M. Yaras ◽  
S. A. Sjolander

The paper presents detailed measurements of the tip-leakage flow emerging from a planar cascade of turbine blades. Four clearances of from 1.5 to 5.5 percent of the blade chord are considered. Measurements were made at the trailing edge plane, and at two main planes 1.0 and 1.56 axial chord lengths downstream of the cascade. The results give insight into several aspects of the leakage flow including: the size and strength of the leakage vortex in relation to the size of the tip gap and the bound circulation of the blade; and the evolution of the components of vorticity as the vortex diffuses laterally downstream of the blade row. The vortex was found to have largely completed its roll-up into a nearly axisymmetric structure even at the trailing edge of the cascade. As a result, it was found that the vortex could be modelled surprisingly well with a simple model based on the diffusion of a line vortex.


Author(s):  
Cengiz Camci ◽  
Debashis Dey ◽  
Levent Kavurmacioglu

This paper deals with an experimental investigation of aerodynamic characteristics of full and partial-length squealer rims in a turbine stage. Full and partial-length squealer rims are investigated separately on the pressure side and on the suction side in the “Axial Flow Turbine Research Facility” (AFTRF) of the Pennsylvania State University. The streamwise length of these “partial squealer tips” and their chordwise position are varied to find an optimal aerodynamic tip configuration. The optimal configuration in this cold turbine study is defined as the one that is minimizing the stage exit total pressure defect in the tip vortex dominated zone. A new “channel arrangement” diverting some of the leakage flow into the trailing edge zone is also studied. Current results indicate that the use of “partial squealer rims” in axial flow turbines can positively affect the local aerodynamic field by weakening the tip leakage vortex. Results also show that the suction side partial squealers are aerodynamically superior to the pressure side squealers and the channel arrangement. The suction side partial squealers are capable of reducing the stage exit total pressure defect associated with the tip leakage flow to a significant degree.


2016 ◽  
Vol 15 (6-7) ◽  
pp. 662-685 ◽  
Author(s):  
Marc C Jacob ◽  
Emmanuel Jondeau ◽  
Bo Li

1991 ◽  
Vol 113 (2) ◽  
pp. 252-259 ◽  
Author(s):  
J. A. Storer ◽  
N. A. Cumpsty

Experimental measurements in a linear cascade with tip clearance are complemented by numerical solutions of the three-dimensional Navier–Stokes equations in an investigation of tip leakage flow. Measurements reveal that the clearance flow, which separates near the entry of the tip gap, remains unattached for the majority of the blade chord when the tip clearance is similar to that typical of a machine. The numerical predictions of leakage flow rate agree very well with measurements, and detailed comparisons show that the mechanism of tip leakage is primarily inviscid. It is demonstrated by simple calculation that it is the static pressure field near the end of the blade that controls chordwise distribution of the flow across the tip. Although the presence of a vortex caused by the roll-up of the leakage flow may affect the local pressure field, the overall magnitude of the tip leakage flow remains strongly related to the aerodynamic loading of the blades.


Author(s):  
W. Sanz ◽  
M. Kelterer ◽  
R. Pecnik ◽  
A. Marn ◽  
E. Go¨ttlich

The demand of a further increased bypass ratio of aero engines will lead to low pressure turbines with larger diameters which rotate at lower speed. Therefore, it is necessary to guide the flow leaving the high pressure turbine to the low pressure turbine at a larger diameter without any loss generating separation or flow disturbances. Due to costs and weight this intermediate turbine duct has to be as short as possible. This leads to an aggressive (high diffusion) S-shaped duct geometry. In order to investigate the influence of the blade tip gap height of a preceding rotor on such a high-diffusion duct flow a detailed measurement campaign in the Transonic Test Turbine Facility at Graz University of Technology has been performed. A high diffusion intermediate duct is arranged downstream a high-pressure turbine stage providing an exit Mach number of about 0.6 and a swirl angle of −15 degrees (counter swirl). A low-pressure vane row is located at the end of the duct and represents the counter rotating low pressure turbine at larger diameter. At the ASME 2007, results of these investigations were presented for two different tip gap heights of 1.5% span (0.8 mm) and 2.4% span (1.3 mm). In order to better understand the flow phenomena observed in the intermediate duct a detailed numerical study is conducted. The unsteady flow through the whole configuration is simulated for both gap heights as well as for a rotor with zero gap height. The unsteady data are compared at the stage exit and inside the duct to study the flow physics. The calculation of the zero gap height configuration allows to determine the influence of the tip leakage flow of the preceding rotor on the intermediate turbine duct. It turns out that for this aggressive duct the tip leakage flow has a very positive effect on the pressure recovery.


Sign in / Sign up

Export Citation Format

Share Document