Experimental and Numerical Investigation on Film Cooling Performance and Flow Structure of Film Holes

Author(s):  
Nan Cao ◽  
Xue Li ◽  
Ze-yu Wu ◽  
Xiang Luo

Abstract Discrete hole film cooling has been commonly used as an effective cooling technique to protect gas turbine blades from hot gas. There have been numerous investigations on the cylindrical hole and shaped hole, but few experimental investigations on the cooling mechanism of the novel film holes with side holes (anti-vortex hole and sister hole) are available. This paper presents an experimental and numerical investigation to study the film cooling performance and flow structure of four kinds of film holes (cylindrical hole, fan-shaped hole, anti-vortex hole and sister hole) on the flat plate. The film holes have the same main hole diameter of 4mm and the same inclination angle of 45°. The adiabatic film cooling effectiveness is obtained by the steady-state Thermochromic Liquid Crystal (TLC). The flow visualization experiment and numerical investigation are performed to investigate the flow structure and counter-rotating vortex pair (CRVP) intensity. The smoke is selected as the tracer particle in the flow visualization experiment. The mainstream Reynolds number is 2900, the blowing ratio ranges from 0.3 to 2.0, and the density ratio of coolant to mainstream is 1.065. Experimental results show that compared with the cylindrical hole, the film cooling performance of the anti-vortex hole and sister hole shows significant improvement at all blowing ratios. The sister hole can achieve the best cooling performance at blowing ratios of 0.3 to 1.5. The fan-shaped hole only performs well at high blowing ratios and it performs best at the blowing ratio of 2.0. Flow visualization experiment and numerical investigation reveal that the anti-vortex hole and sister hole can decrease the CRVP intensity of the main hole and suppress the coolant lift-off because of side holes, which increases the film coverage and cooling effectiveness. For the sister hole, the side holes are parallel to the main hole, but for the anti-vortex hole, there are lateral angles between them. The coolant interaction between the side holes and main hole of the sister hole is stronger than that of the anti-vortex hole. Therefore, the sister hole provides better film cooling performance than the anti-vortex hole.

Author(s):  
Chao Zhang ◽  
Jie Wang ◽  
Xin Luo ◽  
Liming Song ◽  
Jun Li ◽  
...  

Abstract In our experiments, the film cooling performance of the configurations combined the different hole with the vortex generator was investigated experimentally, measured by the infrared camera. Four different configurations were studied at the blowing ratio varying at M = 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0. In all cases, the Reynold number of the mainstream based on the hole diameter remained at Re = 8000, and the density ratio kept at DR = 1.7. Experimental results show that for the two models combining the cylindrical hole and fan-shaped hole with the vortex generator respectively, the film cooling performance becomes better when the blowing ratio increases from M = 0.5 to M = 2.0, and then decreases when the blowing ratio increases from M = 2.0 to M = 3.0. The model combining the fan-shaped hole with the vortex generator performs the best among the four models at each blowing ratio. Its film attachment holds the most extensive lateral distribution and its overall film cooling effectiveness could keep at a high level at a wide range of blowing ratios from M = 1.0 to M = 3.0. The combined model of the fan-shaped hole could improve the area-averaged film effectiveness at most 25.5% than that of the single hole model at M = 2.0. Moreover, the combined model of the cylindrical hole could improve the area-averaged film cooling effectiveness at most 431% than that of the single cylindrical hole model at M = 3.0.


Author(s):  
Jianxia Luo ◽  
Cunliang Liu ◽  
Huiren Zhu

Film cooling performances of three film holes have been numerical researched in this paper, including a lateral inclined cylindrical hole, a fan-shaped hole and a y-shaped hole. The simulation is computed by the commercial software Fluent based on Reynolds Averaged Navier-Stokes (RANS) equations and realizable k-ε turbulence model with enhanced wall treatment. The y-shaped hole is a novel film hole developed from the lateral inclined cylindrical hole. With inner crossflow, the jet of the lateral inclined cylindrical hole performs to be two streams as a result of the helical motion in the hole. Accordingly, the hole exit was optimized with two expansions: one is expanded along the lateral inclined direction and the other is expanded along the mainstream flow direction. The lateral inclined cylindrical hole with two expansions at the exit is named the y-shaped hole. Compared to the fundamental lateral inclined cylindrical hole, the y-shaped hole has different counter-rotating vortices and much better film coverage. Experiments have been conducted to test the film cooling performance of the y-shaped hole. Compared to the lateral inclined cylindrical hole, much higher film cooling effectiveness has been measured in the y-shaped hole as a result of the enhanced lateral film coverage and the weakened film dissipation in the streamwise direction. The film performance of the y-shaped hole rises with the increase of the blowing ratio. At M = 2.0, the film of the y-shaped hole keeps close to the wall while the film of the lateral inclined cylindrical hole is completely lifted up, resulting in the increase of the area average film cooling effectiveness up to 128.7%.


2021 ◽  
Author(s):  
Jie Wang ◽  
Chao Zhang ◽  
Xuebin Liu ◽  
Liming Song ◽  
Jun Li ◽  
...  

Abstract Aiming at investigating the effects of crossflow and vortex generator on film cooling characteristics of fan-shaped hole, the film cooling performance was measured experimentally by infrared camera. The blowing ratio is fixed at 0.5 and 1.5. The Reynolds number of the mainstream based on the hole diameter remains at 7000 and the inlet Reynolds number of crossflow is 40000. The experimental results show that the film cooling performance becomes better when the blowing ratio increases from 0.5 to 1.5 for each model, and the film cooling performance becomes worse under the influence of crossflow. When the blowing ratio is 1.5, the area-averaged film cooling effectiveness of the fan-shaped hole model with vortex generator decreases by 16.6% because of the influence of crossflow. The combined model always performs better compared with the model without vortex generator under all working conditions. When the blowing ratio becomes 1.5, under the influence of crossflow, the area-averaged film cooling effectiveness of the combined model could increase by 14.8%, compared with the model without vortex generator. To further improve the film cooling performance, the global optimization algorithm based on the Kriging method and the CFD technology are coupled to optimize the combined model under crossflow condition at the high blowing ratio, and the optimized design is verified by experiments. The experimental results show that the area-averaged film cooling effectiveness of the optimized design increases by 17.8% compared with the reference model.


2021 ◽  
pp. 1-28
Author(s):  
Zhi-Qiang Yu ◽  
Jianjun Liu ◽  
Chen Li ◽  
Baitao An ◽  
Guang-Yao Xu

Abstract This paper focuses on the influences of the discrete hole shape and layout on the blade endwall film cooling effectiveness. The diffusion slot hole was first applied to the blade endwall and compared with the fan-shaped hole. The effect of upstream purge slot injection on the film cooling performance of the discrete hole was also investigated. Experiments were performed in a linear cascade with a exit Reynolds number of 2.64×105. The film cooling effectiveness on the blade endwall were measured by the pressure sensitive paint technique. Results indicate that the diffusion slot hole significantly increases the film cooling effectiveness on the blade endwall compared to the fan-shaped hole, especially at high blowing ratio. The maximum relative increment of the cooling effectiveness is over 40%. The layout with the discrete holes arranged lining up with the tangent direction of the blade profile offset curves exhibits a comparable film cooling effectiveness with the layout with the discrete holes arranged according to the cross-flow direction. The film cooling effectiveness on the pressure surface corner is remarkably enhanced by deflecting the hole orientation angle towards the pressure surface. The combination of purge slot and diffusion slot holes supplies a full coverage film cooling for the entire blade endwall at coolant mass flow ratio of the purge slot of 1.5% and blowing ratio of 2.5. In addition, the slot injection leads to a non-negligible influence on the cooling performance of the discrete holes near the separation line.


Author(s):  
Zhong-yi Fu ◽  
Hui-ren Zhu ◽  
Cong Liu ◽  
Zheng Li

An experimental research of film cooling performance of three single dust-pan shaped hole rows in different positions of a turbine blade was carried out in the short-duration transonic linear cascade at stationary condition, which can model realistic engine aerodynamic conditions. The effects of inlet Reynolds number (Rein = 2.5 × 105∼7.5 × 105), isentropic exit Mach number (Mais = 0.71∼0.91) and coolant blowing ratio (M = 0.8∼2.6) on film cooling effectiveness are investigated. Three single hole rows are located at 11.7%, 36.3% and 55.6% relative arc on the pressure sides of three enlarged blade models respectively. The adiabatic film cooling effectiveness are derived from the surface temperatures based on transient heat transfer measurement method. The results show that in the range of blowing ratios studied in the present paper, for location 3 the cooling effectiveness decreases a lot with blowing ratio increasing due to the lift-off of coolant at high blowing ratios, while for location 1 and 2, the film cooling effectiveness increases with blowing ratio increasing, because the strong favorable pressure gradient and high concave curvature near the leading edge lead to a good attachment of coolant on the surface. At M≤1.0 conditions, the film cooling effectiveness of location 1 and 2 is lower than that of location 3, which reflects that strong favorable pressure gradient and high concave curvature weaken film cooling performance at low blowing ratio conditions, while the effect is opposite when M is greater than 1.0. For location 1, the highest general cooling performance is obtained at Rein = 2.5 × 105 condition, and for location 2, the change of Rein has different effects on cooling effectiveness in different regions. In the range of Mais studied in this paper, the change of Mais has little effect on film cooling effectiveness.


Author(s):  
Siavash Khajehhasani ◽  
Bassam Jubran

A numerical investigation of the film cooling performance from novel sister shaped single-holes (SSSH) is presented in this paper and the obtained results are compared with a single cylindrical hole, a forward diffused shaped hole, as well as discrete sister holes. Three types of the novel sister shaped single-hole schemes namely downstream, upstream and up/downstream SSSH, are designed based on merging the discrete sister holes to the primary hole in order to reduce the jet lift-off effect and increase the lateral spreading of the coolant on the blade surface as well as a reduction in the amount of coolant in comparison with discrete sister holes. The simulations are performed using three-dimensional Reynolds-Averaged Navier Stokes analysis with the realizable k–ε model combined with the standard wall function. The upstream SSSH demonstrates similar film cooling performance to that of the forward diffused shaped hole for the low blowing ratio of 0.5. While it performs more efficiently at M = 1, where the centerline and laterally averaged effectiveness results improved by 70% and 17%, respectively. On the other hand, the downstream and up/downstream SSSH schemes show a considerable improvement in film cooling performance in terms of obtaining higher film cooling effectiveness and less jet lift-off effect as compared with the single cylindrical and forward diffused shaped holes for both blowing ratios of M = 0.5 and 1. For example, the laterally averaged effectiveness for the downstream SSSH configuration shows an improvement of approximately 57% and 110% on average as compared to the forward diffused shaped hole for blowing ratios of 0.5 and 1, respectively.


Author(s):  
Lin Ye ◽  
Cun-liang Liu ◽  
Hai-yong Liu ◽  
Hui-ren Zhu ◽  
Jian-xia Luo

To investigate the effects of the inclined ribs on internal flow structure in film hole and the film cooling performance on outer surface, experimental and numerical studies are conducted on the effects of rib orientation angle on film cooling of compound cylindrical holes. Three coolant channel cases, including two ribbed cross-flow channels (135° and 45° angled ribs) and the plenum case, are studied under three blowing ratios (0.5, 1.0 and 2.0). 2D contours of film cooling effectiveness as well as heat transfer coefficient were measured by transient liquid crystal measurement technique (TLC). The steady RANS simulations with realizable k-ε turbulence model and enhanced wall treatment were performed. The results show that the spanwise width of film coverage is greatly influenced by the rib orientation angle. The spanwise width of the 45° rib case is obviously larger than that of the 135° rib case under lower blowing ratios. When the blowing ratio is 1.0, the area-averaged cooling effectiveness of the 135° rib case and the 45° rib case are higher than that of the plenum case by 38% and 107%, respectively. With the increase of blowing ratio, the film coverage difference between different rib orientation cases becomes smaller. The 45° rib case also produces higher heat transfer coefficient, which is higher than the 135° rib case by 3.4–8.7% within the studied blowing ratio range. Furthermore, the discharge coefficient of the 45° rib case is the lowest among the three cases. The helical motion of coolant flow is observed in the hole of 45° rib case. The jet divides into two parts after being blown out of the hole due to this motion, which induces strong velocity separation and loss. For the 135° rib case, the vortex in the upper half region of the secondary-flow channel rotates in the same direction with the hole inclination direction, which leads to the straight streamlines and thus results in lower loss and higher discharge coefficient.


Author(s):  
Rui Zhu ◽  
Gongnan Xie ◽  
Terrence W. Simon

Secondary holes to a main film cooling hole are used to improve film cooling performance by creating anti-kidney vortices. The effects of injection angle of the secondary holes on both film cooling effectiveness and surrounding thermal and flow fields are investigated in this numerical study. Two kinds of primary hole shapes are adopted. One is a cylindrical hole, the other is a horn-shaped hole which is designed from a cylindrical hole by expanding the hole in the transverse direction to double the hole size at the exit. Two smaller cylindrical holes, the secondary holes, are located symmetrically about the centerline and downstream of the primary hole. Three compound injection angles (α = 30°, 45° and 60°, β = 30°) of the secondary holes are analyzed while the injection angle of the primary hole is kept at 45°. Cases with various blowing ratios are computed. It is shown from the simulation that cooling effectiveness of secondary holes with a horn-shaped primary hole is better than that with a cylindrical primary hole, especially at high blowing ratios. With a cylindrical primary hole, increasing inclination angle of the secondary holes provides better cooling effectiveness because the anti-kidney vortices created by shallow secondary holes cannot counteract the kidney vortex pairs adequately, enhancing mixing of main flow and coolant. For secondary holes with a horn-shaped primary hole, large secondary hole inclination angles provide better cooling performance at low blowing ratios; but, at high blowing ratios, secondary holes with small inclination angles are more effective, as the film coverage becomes wider in the downstream area.


2018 ◽  
Vol 140 (12) ◽  
Author(s):  
Bai-Tao An ◽  
Jian-Jun Liu

This paper presents a numerical investigation of the film-cooling performance of a kind of diffusion hole with a fusiform cross section. Relative to the rectangular diffusion hole, the up- and/or downstream wall of the fusiform diffusion hole is outer convex. Under the same metering section area, six fusiform diffusion holes were divided into two groups with cross-sectional widths of W = 1.7D and W = 2.0D, respectively. Three fusiform cross section shapes in each group included only downstream wall outer convex, only upstream wall outer convex, or a combination of both. Simulations were performed in a flat plate model using a 3D steady computational fluid dynamics method under an engine-representative condition. The simulation results showed that the fusiform diffusion hole with only an outer convex upstream wall migrates the coolant laterally toward the hole centerline, and then forms or enhances a tripeak effectiveness pattern. Conversely, the fusiform diffusion hole with an outer convex downstream wall intensely expands the coolant to the hole two sides, and results in a bipeak effectiveness pattern, regardless of the upstream wall shape. Compared with the rectangular diffusion holes, the fusiform diffusion holes with only an upstream wall outer convex significantly increase the overall effectiveness at high blowing ratios. The increased magnitude is approximately 20% for the hole of W = 1.7D at M = 2.5. Besides, the fusiform diffusion holes with an outer convex upstream wall increase the discharge coefficient about 5%, within the moderate to high blowing ratio range.


Sign in / Sign up

Export Citation Format

Share Document