Film Cooling and Heat Transfer Performance of a Fully-Cooled Turbine Vane at Varied Density Ratios and Mass Flow Ratios

Author(s):  
Chun-yi Yao ◽  
Hui-ren Zhu ◽  
Cun-liang Liu ◽  
Bo-lun Zhang ◽  
Xin-lei Li

Abstract A number of experimental studies have been performed to study the effect of geometric and aerodynamic parameters on the film cooling performance on the flat plate and turbine blade, however, the experimental investigations on a fully-cooled turbine vane is limited, especially at different density ratios. Consequently, an experiment on a fully-cooled turbine vane with multi-row film cooling holes was carried out to investigate the effect of mass flow ratio and density ratio on the film cooling performance, in which the film cooling effectiveness and heat transfer coefficient was measured by transient liquid crystal. The mainstream inlet Reynolds number based on the inlet velocity and the true chord length is 120000 and the mainstream turbulence intensity is 15%, three mass flow ratios of 5.5%, 8.4% and 11% and two density ratios of 1.0 and 1.5 were tested. The air was selected as the mainstream, the air and carbon dioxide were independently selected as secondary flow to produce two density ratios of 1.0 and 1.5. The test vane is similar in geometry to a first stage turbine vane of a normal aeroengine. Two cavities were manufactured in the test vane to feed 18 rows of film cooling holes. Results show that with the mass flow ratio increasing for DR = 1.0 and 1.5, the film cooling effectiveness on pressure side gradually increases, however, that on the suction side gradually decreases. Generally, increased density ratio produces higher film cooling effectiveness because the injection momentum was reduced, however, the film cooling effectiveness on the suction side for DR = 1.5 is lower than that for DR = 1.0. The coolant outflow significantly enhances the surface heat transfer coefficient for 0 < S/C < 0.5 and S/C < −0.5. The heat transfer coefficient in the leading edge is less affected by the density ratio, however, the increase in density ratio reduces the heat transfer coefficient ratio in other regions, especially for large mass flow ratios.

Author(s):  
Chunyi Yao ◽  
Zheng Zhang ◽  
Bo-lun Zhang ◽  
Hui Ren Zhu ◽  
Cun Liang Liu

Abstract The objective of this experimental investigation was to determine the cooling performance of a fully cooled vane with 18 rows of cylinder cooling holes. The exit Reynolds number in the wind tunnel normalized by the true chord was 500,000 with a turbulence intensity of 15%. The film cooling effectiveness and heat transfer coefficient distribution were obtained by the transient liquid crystal technology, three mass flow ratios (MFR=7.0%, 9.9%, 11%) and two density ratios (DR=1.0, 1.5) were tested. The results show that the film cooling effectiveness distribution on the suction side is more uniform and the coolant injection trajectory is much longer than that on the pressure side. As the density ratio increasing to 1.5, the more laterally uniform film cooling effectiveness contour on the pressure side is observed and the spatially averaged film cooling effectiveness is increased by 11%∼43%. For the MFR=7.0%, the coolant injection with low momentum thickens the boundary layer and reduces the heat transfer coefficient in the mid-chord region of the pressure side. Both the increased mass flow ratio and decreased density ratio result in a higher heat transfer coefficient, while do not alter the distribution trend. By calculating the heat flux ratio, the reduction in the heat flux at DR=1.5 is found to be within 20% in most areas than that of DR=1.0 on the vane surface.


Author(s):  
R. F. Martinez-Botas ◽  
C. H. N. Yuen

An efficient steady-state wide band liquid crystal technique is used to study the film cooling performance of a variety of geometries in a flat plate: a single row of holes, a double row of holes (both in-line and staggered), and a single cooling hole. This method allows temperature information to be captured in one image, without the difficulty involved in a transient experiment. The streamwise inclinations tested are 30°, 60°, and 90°. The freestream is maintained at 13m/s, and at ambient temperature. The range of blowing ratios varied from 0.33 to 2.0. Both heat transfer coefficient and adiabatic cooling effectiveness are measured for all the cases. Air is used to produce a density ratio near unity. From the range of blowing ratios tested, the most effective film cooling is achieved at a value close to 0.5, for near unity density ratio. It has been revealed that film cooling effectiveness is improved when the jet remains attached to the surface, however, this is generally coupled with an augmentation in heat transfer owing to the disturbance the attached jet causes to the boundary layer. The 30° inclined holes show to be the most effective. Results demonstrate the full coverage capability of liquid crystal thermography.


Author(s):  
Renzo La Rosa ◽  
Jaideep Pandit ◽  
Wing Ng ◽  
Brett Barker

Abstract Heat transfer experiments were done on a flat plate to study the effect of internal counter-flow backside cooling on adiabatic film cooling effectiveness and heat transfer coefficient. In addition, the effects of density ratio (DR), blowing ratio (BR), diagonal length over diameter (L/D) ratio, and Reynolds number were studied using this new configuration. The results are compared to a conventional plenum fed case. Data were collected up to X/D = 23 where X = 0 at the holes, an S/D = 1.65 and L/D = 1 and 2. Testing was done at low L/D ratios since short holes are normally found in double wall cooling applications in turbine components. A DR of 2 was used in order to simulate engine-like conditions and this was compared to a DR of 0.92 since relevant research is done at similar low DR. The BR range of 0.5 to 1.5 was chosen to simulate turbine conditions as well. In addition, previous research shows that peak effectiveness is found within this range. Infrared (IR) thermography was used to capture temperature contours on the surface of interest and the images were calibrated using a thermocouple and data analyzed through MATLAB software. A heated secondary fluid was used as ‘coolant’ in the present study. A steady state heat transfer model was used to perform the data reduction procedure. Results show that backside cooling configuration has a higher adiabatic film cooling effectiveness when compared to plenum fed configurations at the same conditions. In addition, the trend for effectiveness with varying BR is reversed when compared with traditional plenum fed cases. Yarn flow visualization tests show that flow exiting the holes in the backside cooling configuration is significantly different when compared to flow exiting the plenum fed holes. We hypothesize that backside cooling configuration has flow exiting the holes in various directions, including laterally, and behaving similar to slot film cooling, explaining the differences in trends. Increasing DR at constant BR shows an increase in adiabatic effectiveness and HTC in both backside cooling and plenum fed configurations due to the decreased momentum of the coolant, making film attachment to the surface more probable. The effects of L/D ratio in this study were negligible since both ratios used were small. This shows that the coolant flow is still underdeveloped at both L/D ratios. The study also showed that increasing turbulence through increasing Reynolds number decreased adiabatic effectiveness.


1999 ◽  
Vol 121 (2) ◽  
pp. 225-232 ◽  
Author(s):  
R. J. Goldstein ◽  
P. Jin ◽  
R. L. Olson

A special naphthalene sublimation technique is used to study the film cooling performance downstream of one row of holes of 35 deg inclination angle with 3d hole spacing and relatively small hole length to diameter ratio (L/d = 6.3). Both film cooling effectiveness and mass/heat transfer coefficient are determined for blowing rates from 0.5 to 2.0 with density ratio of 1.0. The mass transfer coefficient is measured using pure air film injection, while the film cooling effectiveness is derived from comparison of mass transfer coefficients obtained following injection of naphthalene-vapor-saturated air with those from pure air injection. This technique enables one to obtain detailed local information on film cooling performance. The laterally averaged and local film cooling effectiveness agree with previous experiments. The difference between mass/heat transfer coefficients and previous heat transfer results indicates that conduction error may play an important role in the earlier heat transfer measurements.


2001 ◽  
Vol 7 (3) ◽  
pp. 153-164 ◽  
Author(s):  
Ping-Hei Chen ◽  
Min-Sheng Hung ◽  
Pei-Pei Ding

In order to explore the effect of blowing ratio on film cooling over a convex surface, the present study adopts the transient liquid crystal thermography for the film cooling measurement on a straight circular hole configuration. The test piece has a strength of curvature(2r/D)of 92.5, pitch to diameter ratio(P/D)of 3 and streamwise injection angle(γ)of35∘All measurements were conducted under the mainstream Reynolds number(Red)of 1700 with turbulence intensity(Tu)of 3.8%, and the density ratio between coolant and mainstream(ρc/ρm)is 0.98. In current study, the effect of blowing ratio(M)on film cooling performance is investigated by varying the range of blowing ratio from 0.5 to 2.0. Two transient tests of different injection flow temperature were conducted to obtain both detailed heat transfer coefficient and film cooling effectiveness distributions of measured region. The present measured results show that both the spanwise averaged heat transfer coefficient and film cooling effectiveness increase with decreased blowing ratio.


2019 ◽  
Vol 141 (9) ◽  
Author(s):  
Andrew J. Saul ◽  
Peter T. Ireland ◽  
John D. Coull ◽  
Tsun Holt Wong ◽  
Haidong Li ◽  
...  

The effect of film cooling on a transonic squealer tip has been examined in a high speed linear cascade, which operates at engine-realistic Mach and Reynolds numbers. Tests have been performed on two uncooled tip geometries with differing pressure side rim edge radii, and a cooled tip matching one of the uncooled cases. The pressure sensitive paint technique has been used to measure adiabatic film cooling effectiveness on the blade tip at a range of tip gaps and coolant mass flow rates. Complementary tip heat transfer coefficients have been measured using transient infrared thermography, and the effects of the coolant film on the tip heat transfer and engine heat flux were examined. The uncooled data show that the tip heat transfer coefficient distribution is governed by the nature of flow reattachments and impingements. The squealer tip can be broken down into three regions, each exhibiting a distinct response to a change in the tip gap, depending on the local behavior of the overtip leakage flow. Complementary computational fluid dynamics (CFD) shows that the addition of casing motion causes no change in the flow over the pressure side rim. Injected coolant interacts with the overtip leakage flow, which can locally enhance the tip heat transfer coefficient. The film effectiveness is dependent on both the coolant mass flow rate and tip clearance. At increased coolant mass flow, areas of high film effectiveness on the pressure side rim coincide strongly with a net heat flux reduction and in the subsonic tip region with low heat transfer coefficient.


2018 ◽  
Vol 35 (3) ◽  
pp. 291-303 ◽  
Author(s):  
Cun-Liang Liu ◽  
Dan Zhao ◽  
Ying-Ni Zhai ◽  
Hui-Ren Zhu ◽  
Yi-Hong He ◽  
...  

AbstractNumerical simulations have been performed on the film cooling characteristics of counter-inclined structures, which have advantage in manufacturing relative to the usually used parallel-inclined film-hole row structure, on a turbine vane leading edge model. Single row structure and dual-row structure with counter-inclined film holes were applied in the simulation of leading edge film cooling of turbine vane. The effect of jet-interaction between counter-inclined film-hole rows was studied. The distributions of film cooling effectiveness and heat transfer coefficient were obtained at blowing ratios of 1.0 and 2.0. The results of single row structure show that the film cooling performances of counter-inclined film-hole row are not weakened compared to the traditional parallel-inclined film-hole row structure. The film cooling effectiveness of the counter-inclined film-hole row structure decreases with the increase of blowing ratio, while the heat transfer coefficient increases. The jet-interaction in the dual-row film cooling structure has more notable influence on the film cooling effectiveness than the heat transfer coefficient. Compared to the single row case, the interactions between the upstream counter-blowing jets and the downstream jet improve the film coverage performance and reduce the heat transfer intensity of this downstream jet under larger blowing ratio condition.


Author(s):  
Andrew J. Saul ◽  
Peter T. Ireland ◽  
John D. Coull ◽  
Tsun Holt Wong ◽  
Haidong Li ◽  
...  

The effect of film cooling on a high pressure turbine blade with an open squealer tip has been examined in a high speed linear cascade. The cascade operates at engine realistic Mach and Reynolds numbers, producing transonic flow conditions over the blade tip. Tests have been performed on two uncooled tip geometries with differing pressure side rim edge radii, and a cooled tip matching one of the uncooled cases. The pressure sensitive paint technique has been used to measure adiabatic film cooling effectiveness on the blade tip at a range of tip gaps and coolant mass flow rates. Complementary tip heat transfer coefficients (HTC) have been measured using transient infrared thermography, and the effects of the coolant film on the tip heat transfer and engine heat flux examined. The uncooled data show that the tip heat transfer coefficient distribution is governed by the nature of flow reattachments and impingements. The squealer tip can be broken down into three regions, each exhibiting a distinct response to a change in the tip gap, depending on the local behaviour of the overtip leakage flow. The edge radius of the pressure side rim causes the overtip leakage flow to change dramatically at low clearance. Complementary CFD shows that the addition of casing motion causes no further change on the pressure side rim. Injected coolant interacts with the overtip leakage flow, which can locally enhance the tip heat transfer coefficient compared to the uncooled tip. The film effectiveness is dependent on both the coolant mass flow rate and tip clearance. At increased coolant mass flow, areas of high film effectiveness on the pressure side rim coincide strongly with a net heat flux reduction and in the subsonic tip region with low heat transfer coefficient.


Author(s):  
R. J. Goldstein ◽  
P. Jin ◽  
R. L. Olson

A special naphthalene sublimation technique is used to study the film cooling performance downstream of one row of holes of 35° inclination angle with 3d hole spacing and relatively small hole length to diameter ratio (L/d = 6.3). Both film cooling effectiveness and mass/heat transfer coefficient are determined for blowing rates from 0.5 to 2.0 with density ratio of 1.0. The mass transfer coefficient is measured using pure air film injection, while the film cooling effectiveness is derived from comparison of mass transfer coefficient obtained following injection of naphthalene-vapor-saturated air with that of pure air injection. This technique enables one to obtain detailed local information on film cooling performance. The laterally-averaged and local film cooling effectiveness agree with previous experiments. The difference between mass/heat transfer coefficients and previous heat transfer results indicates that conduction error may play an important role in the earlier heat transfer measurements.


2004 ◽  
Vol 10 (5) ◽  
pp. 345-354 ◽  
Author(s):  
Jan Dittmar ◽  
Achmed Schulz ◽  
Sigmar Wittig

The demand of improved thermal efficiency and high power output of modern gas turbine engines leads to extremely high turbine inlet temperature and pressure ratios. Sophisticated cooling schemes including film cooling are widely used to protect the vanes and blades of the first stages from failure and to achieve high component lifetimes. In film cooling applications, injection from discrete holes is commonly used to generate a coolant film on the blade's surface.In the present experimental study, the film cooling performance in terms of the adiabatic film cooling effectiveness and the heat transfer coefficient of two different injection configurations are investigated. Measurements have been made using a single row of fanshaped holes and a double row of cylindrical holes in staggered arrangement. A scaled test model was designed in order to simulate a realistic distribution of Reynolds number and acceleration parameter along the pressure side surface of an actual turbine guide vane. An infrared thermography measurement system is used to determine highly resolved distribution of the models surface temperature. Anin-situcalibration procedure is applied using single embedded thermocouples inside the measuring plate in order to acquire accurate local temperature data.All holes are inclined 35° with respect to the model's surface and are oriented in a streamwise direction with no compound angle applied. During the measurements, the influence of blowing ratio and mainstream turbulence level on the adiabatic film cooling effectiveness and heat transfer coefficient is investigated for both of the injection configurations.


Sign in / Sign up

Export Citation Format

Share Document