Spent Resin Treatment Test in the ATR Fugen Nuclear Power Station Using Low Pressure Oxygen ICP

Author(s):  
Kazuya Sano ◽  
Norikazu Higashiura ◽  
Genichi Katagiri ◽  
Morio Fujisawa ◽  
Takeo Shimamura

Low-pressure oxygen plasma processing using ICP (Inductively coupled plasma) is the technology that takes volume reduction and stabilizing treatment of an organic material such as ion exchange resin mildly. We evaluated, for example, treatment performance such as the volume reduction, the weight reduction, and γ specter, H-3,C-14 for the spent ion exchange resin which has actually been produced in the ATR Fugen power station. As a result, a volume reduction rate was achieved not less than 90% (1/10), and a weight reduction rate not less than 95% (1/20). Co −60 was held not less than 0.998 in a processing chamber. In addition, distribution to an effluent gas was not more than 10−6.

Author(s):  
Gen-ichi Katagiri ◽  
Morio Fujisawa ◽  
Kazuya Sano ◽  
Norikazu Higashiura

Fuji Electric had developed the low pressure oxygen plasma technology for mild decomposition and mineralization of an organic material such as ion exchange resin. This method is suitable for radioactive spent resin volume/weight reduction and stabilization for final disposal. On this process, the ion-exchange resins are vaporized and decomposed into gas-phase with pyrolysis, and then, they are decomposed and oxidized with low-pressure plasma activity based on oxygen. And this process is achieved under moderate condition for radio active waste. • incinerate temperature: 400–700 deg C; • low-pressure (low-temperature) plasma condition: 10–50 Pa. From the result of this process, named of LPOP(low pressure oxidation process) by the inductively coupled plasma, we have confirmed that the process is applicable for organic fireproof waste including ion-exchange resin, and found that the used resin treatment performance is the same as cold test (using imitate spent resin) [1] [2] [3]. In this paper, the outline of the LPOP technology, and two research results on the possibility of solidification with cement of LPOP residue for geological disposes are reported. (1)Study of the residue chemical form after LPOP process (2)Study of the solidification character with cement.


2022 ◽  
Vol 2155 (1) ◽  
pp. 012024
Author(s):  
I I Sadikov ◽  
B Kh Yarmatov ◽  
T M Usmanov

Abstract The work is devoted to the development of methods for determining the elemental and isotopic composition of spent ion-exchange resin, industrial waste and environmental objects using an inductively coupled plasma mass spectrometer and analyzing specific samples to determine the content of noble and rare metals in technological materials, industrial waste and natural objects with application of the developed techniques. This article determines the elemental composition of the spent ion-exchange resin SIM202 with the Inductively coupled plasma mass spectrometry (ICP-MS) method and also shows the comparison of the results with neutron activation analysis (NAA). The distribution coefficient of elements in a chromatographic column in ion-exchange resins TAO and SIM202 is given.


2019 ◽  
Vol 11 (11) ◽  
pp. 3129 ◽  
Author(s):  
Po-Kang Shih ◽  
Li-Chi Chiang ◽  
Sheng-Chi Lin ◽  
Tsun-Kuo Chang ◽  
Wei-Chan Hsu

Many factories were built and scattered around the farmlands in Taiwan due to inappropriate land use planning. Illegal effluent discharge of high concentration of metals from the nearby factories has been threatening the farmlands, causing damages to agricultural production, food safety, and human health. Sampling was mostly responsible for monitoring the water quality of the agricultural environment; however, the analysis is of high cost and time consuming. Due to uneasy controlled environmental factors (i.e., illegal effluents) and time-consuming and expensive traditional analysis techniques (i.e., atomic absorption spectrometry (AAS), atomic fluorescence spectrometry (AFS), inductively coupled plasma atomic emission spectrometry (ICP-AES), inductively coupled plasma optical emission spectrometry (ICP-OES), and inductively coupled plasma mass spectrometry (ICP-MS)), we develop a fast-screening method, which is the combination of ion exchange resins and the portable X-ray fluorescence (XRF) spectroscopy to identify the source of contaminants in a mixed industrial and agricultural area in Taoyuan County, Taiwan. The time-lapse ion exchange resin sachet (TIERS) is a non-woven bag that is filled with resins and placed in the irrigation channels for continuously absorbing the metal and trace elements in water. The standardization ratios of Cu/Sr and Zn/Sr were calculated as the pollutant indicators for fast-screening the highly polluted sites of exceedance probability of 2.27% in the monitoring area. The TIERS is verified to detect the metal and trace element concentration in an efficient and sufficient way.


2016 ◽  
Vol 52 ◽  
pp. 171-176
Author(s):  
M. Palkina ◽  
O. Metlitska

The aim of the research – adaptation, optimization and using of existing DNA extraction methods from bees’ biological material with the reagent «Chelex-100" under complex economic conditions of native laboratories, which will optimize labour costs and improve the economic performance of DNA extraction protocol. Materials and methods. In order to conduct the research the samples of honey bees’ biological material: queen pupae exuviae, larvae of drone brood, some adult bees’ bodies (head and thorax) were selected. Bowl and drone brood were obtained from the experimental bee hives of Institute of Apiculture nd. a. P. I. Prokopovich of NAAS. DNA extraction from biosamples of Apis mellifera ssp. was carried out using «Chelex-100®» ion exchange resin in different concentrations and combinations. Before setting tests for determination of quantitative and quality indexes, dilution of DNA samples of the probed object was conducted in ratio 1:40. The degree of contamination with protein and polysaccharide fractions (OD 260/230), quantitative content of DNA (OD 260/280) in the extracted tests were conducted using spectrophotometer of «Biospec – nano» at the terms of sample volume in 2 µl and length of optical way in 0,7 mm [7]. Verification of DNA samples from biological material of bees, isolated by «Chelex-100®», was conducted after cold keeping during 24 hours at 20°C using PСR with primaries to the fragment of gene of quantitative trait locus (QTL) Sting-2 of next structure [8]:  3' – CTC GAC GAG ACG ACC AAC TTG – 5’; 3' – AAC CAG AGT ATC GCG AGT GTT AC – 5’ Program of amplification: 94 °C – 5 minutes – 1 cycle; 94 °C – 1 minute, 57°C – 1 minute, 72 °C – 2 minutes – 30 cycles; elongation after 72°C during 2 minutes – 1 cycle. The division of obtained amplicons was conducted by gel electrophoresis at a low current – 7 µÀ, in 1,5 % agarose gel (Sigma ®) in TAE buffer [7]. The results. At the time of optimization of DNA isolation methods, according to existing methods of foreign experts, it was found optimal volume of ion exchange resin solution was in the proposed concentration: instead of 60 µl of solution used 120 µl of «Chelex-100®», time of incubation was also amended from 30 minutes to 180 minutes [9]. The use of the author's combination of method «Chelex-100®» with lysis enzymes, proteinase K and detergents (1M dithiothreitol), as time of incubation was also amended, which was reduced to 180 minutes instead of the proposed 12 hours [10]. Changes in quality characteristics of obtained DNA in samples after reduction in incubation time were not found. Conclusions. The most economical method of DNA isolation from bees’ biological material is 20% solution of «Chelex-100» ion exchange resin with the duration of the incubation period of 180 minutes. It should also be noted that the best results can be obtained from exuviae, selected immediately after the queen’s exit from bowl, that reduces the likelihood of DNA molecules destruction under the influence of nucleases activation, but not later than 12 hours from release using the technology of isolated obtain of queens.