Two-Phase Critical Flow Simulations by Using a New Non-Equilibrium Model and a Modified Equilibrium Model

Author(s):  
Moon-Sun Chung ◽  
Sung-Jae Yi ◽  
Keun-Shik Chang

An accurate prediction of a critical flow discharged from a pressurized pipe system is of most importance in such a safety analysis of nuclear power plants, since it provides the transient boundary conditions during the depressurization transients initiated by a pipe break in primary or secondary systems and during the over-pressurization transients resulting in a relief of coolant through valves. Mass and energy discharge through the opening of pressure boundary affects the system thermal hydraulic responses, that is, phase changes and flow distribution in the system, and the mass inventory remaining in the system necessary to remove core decay heat of a nuclear reactor. Therefore, the safety significance relating to the critical flow led to a development of various empirical and mechanistic critical flow models. However, the accuracies of these models are still in question especially during two-phase critical flow condition. A good example of that is a homogeneous equilibrium model (HEM). The HEM is the basis of several system codes, such as early versions of RELAP, for nuclear loss-of-coolant accident (LOCA). The major non-equilibrium phenomena that are ignored in the HEM are vapor bubble nucleation and interface heat, mass, and momentum transfer. Henry-Fauske empirically handled non-equilibrium vapor generation by introducing a non-equilibrium parameter that allows only a fraction of the equilibrium vapor generation to occur. This approach boils down in essence to a correlation of the deviation between the measured flow rate and the prediction from the HEM: The details of the flow path do not have to be worked out and only needs to know the upstream conditions. However, if we treat non-equilibrium phenomena with this model, it requires an empirical database of the non-equilibrium parameters or their correlations that are so far unknown. Further, because the coefficients are not applied separately to the subcooled liquid and two-phase mixture, we have not been able to treat the non-equilibrium phenomena with the phase change properly. For this reason, we propose the non-equilibrium parameters for subcooled liquid and two-phase mixture, respectively, and then we adopt their combinations according to the flow conditions through the phase change process using the RELAP5/MOD3 code. In addition, we discuss the assessment results of Marviken LBLOCA tests using these non-equilibrium parameter sets with those from the non-equilibrium model by Trapp-Ransom and Chung et al.

Author(s):  
Moon-Sun Chung ◽  
Sung-Jae Lee

An accurate prediction of a critical flow discharged from a pressurized pipe system is of most importance in such a safety analysis of nuclear power plants, since it provides the transient boundary conditions during the depressurization transients initiated by a pipe break in primary or secondary systems and during the over-pressurization transients resulting in a relief of coolant through valves. Mass and energy discharge through the opening of pressure boundary affects the system thermal hydraulic responses, that is, phase changes and flow distribution in the system, and the mass inventory remaining in the system necessary to remove core decay heat of a nuclear reactor. Therefore, the safety significance relating to the critical flow led to a development of various empirical and mechanistic critical flow models. However, the accuracies of these models are still in question especially during two-phase critical flow condition. A good example of that is a homogeneous equilibrium model (HEM). The HEM is the basis of several system codes, such as early versions of RELAP, for nuclear loss-of-coolant accident (LOCA). The major non-equilibrium phenomena that are ignored in the HEM are vapor bubble nucleation and interface heat, mass, and momentum transfer. Henry & Fauske empirically handled non-equilibrium vapor generation by introducing a non-equilibrium parameter that allows only a fraction of the equilibrium vapor generation to occur. This approach boils down in essence to a correlation of the deviation between the measured flow rate and the prediction from the HEM: The details of the flow path do not have to be worked out and only needs to know the upstream conditions. However, if we treat non-equilibrium phenomena with this model, it requires an empirical database of the non-equilibrium parameters or their correlations that are so far unknown. Further, because the coefficients have not been applied separately to the subcooled liquid and two-phase mixture, we have not been able to treat the non-equilibrium phenomena with the phase change properly. For this reason, we propose the non-equilibrium parameters for subcooled liquid and two-phase mixture, respectively, and then we adopt their combinations according to the flow conditions through the phase change process using the RELAP5/MOD3 code. In addition, we discuss the assessment results of Marviken LBLOCA tests using these non-equilibrium parameter sets with those from the non-equilibrium model by Trapp & Ransom and Chung et al.


2021 ◽  
Vol 372 ◽  
pp. 110998
Author(s):  
Hong Xu ◽  
Aurelian Florin Badea ◽  
Xu Cheng

Author(s):  
A. E. Bergles ◽  
J. T. Kelly

This paper summarizes an experimental investigation of steam-water critical flow in heated tubes. A wide range of data was taken for water at pressures below 100 lbf/in2 (abs.) in tubes of small diameter. It is demonstrated that critical flow conditions can occur in subcooled boiling at low exit subcoolings. At equilibrium qualities below about 0·04, the data differ significantly from adiabatic data for a similar exit geometry. The deviations can be explained in terms of the additional non-equilibrium effects present in heated flows. For higher qualities, the diabatic data are in good agreement with adiabatic data, and can be approximately predicted by a slip equilibrium model.


Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3634
Author(s):  
Grzegorz Czerwiński ◽  
Jerzy Wołoszyn

With the increasing trend toward the miniaturization of electronic devices, the issue of heat dissipation becomes essential. The use of phase changes in a two-phase closed thermosyphon (TPCT) enables a significant reduction in the heat generated even at high temperatures. In this paper, we propose a modification of the evaporation–condensation model implemented in ANSYS Fluent. The modification was to manipulate the value of the mass transfer time relaxation parameter for evaporation and condensation. The developed model in the form of a UDF script allowed the introduction of additional source equations, and the obtained solution is compared with the results available in the literature. The variable value of the mass transfer time relaxation parameter during condensation rc depending on the density of the liquid and vapour phase was taken into account in the calculations. However, compared to previous numerical studies, more accurate modelling of the phase change phenomenon of the medium in the thermosyphon was possible by adopting a mass transfer time relaxation parameter during evaporation re = 1. The assumption of ten-fold higher values resulted in overestimated temperature values in all sections of the thermosyphon. Hence, the coefficient re should be selected individually depending on the case under study. A too large value may cause difficulties in obtaining the convergence of solutions, which, in the case of numerical grids with many elements (especially three-dimensional), significantly increases the computation time.