Effect of Thermal Radiation on Accuracy of Restricted Domain Approach in a Square Open Cavity

Author(s):  
Om Singh ◽  
Suneet Singh ◽  
Shireesh B. Kedare

To reduce computational time for simulation of natural convection in open cavities, it is quite common to use a domain restricted to the cavity with approximate boundary conditions at the cavity opening. It had been shown that such approach leads to quite accurate solutions for high Rayleigh number (Ra) flows. Such approach has been extended to flows involving radiative heat transfer as well. However, it is important to note that the effect of radiation on the accuracy of restricted domain approach has not been evaluated. In the present work, a comparison of Nusselt numbers is obtained by restricted domain approach with those obtained by using extended domain approach. The convective as well as radiative Nusselt numbers are considered for comparison for various values of Ra and radiation conduction parameter (Nr). It is observed that the accuracy of the restricted domain approach varies with the radiation conduction parameter as well and the approach is found to be quite accurate for high values of Nr.

1995 ◽  
Vol 117 (4) ◽  
pp. 910-917 ◽  
Author(s):  
T. J. Heindel ◽  
F. P. Incropera ◽  
S. Ramadhyani

Three-dimensional numerical predictions and experimental data have been obtained for natural convection from a 3 × 3 array of discrete heat sources flush-mounted on one vertical wall of a rectangular cavity and cooled by the opposing wall. Predictions performed in a companion paper (Heindel et al., 1995a) revealed that three-dimensional edge effects are significant and that, with increasing Rayleigh number, flow and heat transfer become more uniform across each heater face. The three-dimensional predictions are in excellent agreement with the data of this study, whereas a two-dimensional model of the experimental geometry underpredicts average heat transfer by as much as 20 percent. Experimental row-averaged Nusselt numbers are well correlated with a Rayleigh number exponent of 0.25 for RaLz ≲ 1.2 × 108.


2019 ◽  
Vol 30 (01) ◽  
pp. 1950006 ◽  
Author(s):  
Abdellaziz Yahiaoui ◽  
Mahfoud Djezzar ◽  
Hassane Naji

This paper performs a numerical analysis of the natural convection within two-dimensional enclosures (square enclosure and enclosures with curved walls) full of a H2O-Cu nanofluid. While their vertical walls are isothermal with a cold temperature [Formula: see text], the horizontal top wall is adiabatic and the bottom wall is kept at a sinusoidal hot temperature. The working fluid is assumed to be Newtonian and incompressible. Three values of the Rayleigh number were considered, viz., 103, 104, 105, the Prandtl number is fixed at 6.2, and the volume fraction [Formula: see text] is taken equal to 0% (pure water), 10% and 20%. The numerical simulation is achieved using a 2D-in-house CFD code based on the governing equations formulated in bipolar coordinates and translated algebraically via the finite volume method. Numerical results are presented in terms of streamlines, isotherms and local and average Nusselt numbers. These show that the heat transfer rate increases with both the volume fraction and the Rayleigh number, and that the average number of Nusselt characterizing the heat transfer raises with the nanoparticles volume fraction.


1982 ◽  
Vol 104 (1) ◽  
pp. 125-131 ◽  
Author(s):  
E. M. Sparrow ◽  
D. S. Cook ◽  
G. M. Chrysler

Per-cylinder natural convection Nusselt numbers were measured for an in-line array of short horizontal cylinders that were affixed to a convectively participating vertical plate. The effect of cylinder length-to-diameter ratio, intercylinder spacing, position at which the cylinder is attached to the vertical plate, and Rayleigh number were investigated. The experiments were performed in air. It was found that the extent to which a given cylinder in the array was affected by cylinders situated below it depended on the Rayleigh number, with enhanced heat transfer coefficients being more likely at higher Rayleigh numbers. Greater enhancement occurred at larger intercylinder spacings. The qualitative characteristics of the Nusselt number results were insensitive to the cylinder length-to-diameter ratio, but the longer cylinders exhibited higher values of the Nusselt number. For the most part, the Nusselt numbers for the wall-attached horizontal cylinders fell below those for the classical horizontal cylinder of infinite length.


1987 ◽  
Vol 109 (2) ◽  
pp. 407-412 ◽  
Author(s):  
A. M. Clausing ◽  
J. M. Waldvogel ◽  
L. D. Lister

An experimental investigation of heat transfer by natural convection from a smooth, isothermal cubic cavity with a variety of side-facing apertures is described in this paper. The study was motivated by the desire to predict the convective loss from large solar thermal-electric receivers and to understand the mechanisms which control this loss. Hence, emphasis is placed on the large Rayleigh number, Ra, regime with large ratios of the cavity wall temperature Tw to the ambient temperature T∞. A cryogenic wind tunnel with test section temperatures which are varied between 80 K and 310 K is used to facilitate deduction of the influences of the relevant parameters and to obtain large temperature ratios without masking the results by radiative heat transfer. A 0.4-m cubic cavity, which is mounted in the side wall of this tunnel, is used. The area of the aperture Aa and its location are key variables in this study. The data which are presented cover the ranges: 1 < Tw/T∞ < 3, L2/18 ≤ Aa ≤ L2, and 3 × 107 < Ra < 3 × 1010.


Author(s):  
T. Javed ◽  
Z. Mehmood ◽  
M.A. Siddiqui ◽  
Ioan Pop

Purpose The purpose of this paper is to perform a numerical study for heat transfer through natural convection in the presence of a constant magnetic field in an incompressible steady nanofluid flow inside an isosceles triangular cavity. Design/methodology/approach For this flow problem, the left wall of the cavity subjected to uniform/nonuniform heat was considered, while right and bottom walls of the cavity were kept cold. The obtained equations were solved by using the Galerkin weighted residual technique. Results are computed for a wide range of parameters including Rayleigh number (Ra) (10^3 < Ra < 10^7), Hartman number (Ha) (0 < Ha < 60), and heat-generation/-absorption coefficient (q) (−10 < q < 10), while, Prandtl number (Pr) was kept fixed at 6.2. These computed results are presented in terms of stream functions, isotherms, Nusselt numbers and average Nusselt numbers through figures. Findings It is observed that, in case of uniform heating of the side wall, the strength of stream lines’ circulations increases with an increase in Ra and decreases with an increase in Ha. Similarly, by increasing heat-absorption coefficient q, an increase in the circulation strength is noted and the circulation cell moves towards the left wall in the presence of a heat sink (q < 0) and moves to the cold right wall in the presence of a heat source (q > 0). In the case of nonuniformly heated left wall in the presence of a heat source (q > 0), a higher-temperature gradient is observed in the cavity and isotherms are clustered to the left wall in the lower portion and to right wall in the upper portion; these appear to be straight and parallel to the x-axis near the bottom wall. On the other hand, the heat transfer rate along all the walls of the cavity is observed to be higher for smaller values of q. Whereas, Nusselt number along the bottom wall (Nu-B) increases with an increase in the values of x, while, that along the left wall (Nu-L) first increases and then decreases. But Nusselt number along the right wall (Nu-R) is found to be qualitatively opposite to Nu-L with an increase in distance x. Whereas, average Nusselt number increases with an increase in Rayleigh number Ra and heat-generation/-absorption coefficient q. Research limitations/implications The problem is formulated for an incompressible flow; viscous dissipation has been neglected, negligible induced magnetic field has been considered and local thermal equilibrium has been considered. Originality/value Results presented in this paper are original and new for the effects of a uniform magnetic field on the natural convection of Cu–water nanofluid in a triangular cavity. Hence, this study is important for researchers working in the area of heat transfer in cavity flows involving the nanofluid to become familiar with the flow behavior and properties.


2010 ◽  
Vol 132 (6) ◽  
Author(s):  
Yuping Duan ◽  
S. F. Hosseinizadeh ◽  
J. M. Khodadadi

The effects of insulated and isothermal thin baffles on pseudosteady-state natural convection within spherical containers were studied computationally. The computations are based on an iterative, finite-volume numerical procedure using primitive dependent variables. Natural convection effect is modeled via the Boussinesq approximation. Parametric studies were performed for a Prandtl number of 0.7. For Rayleigh numbers of 104, 105, 106, and 107, baffles with three lengths positioned at five different locations were investigated (120 cases). The fluid that is heated adjacent to the sphere rises replacing the colder fluid, which sinks downward through the stratified stable thermal layer. For high Ra number cases, the hot fluid at the bottom of the sphere is also observed to rise along the symmetry axis and encounter the sinking colder fluid, thus causing oscillations in the temperature and flow fields. Due to flow obstruction (blockage or confinement) effect of baffles and also because of the extra heating afforded by the isothermal baffle, multi-cell recirculating vortices are observed. This additional heat is directly linked to creation of another recirculating vortex next to the baffle. In effect, hot fluid is directed into the center of the sphere disrupting thermal stratified layers. For the majority of the baffles investigated, the Nusselt numbers were generally lower than the reference cases with no baffle. The extent of heat transfer modification depends on Ra, length, and location of the extended surface. With an insulated baffle, the lowest amount of absorbed heat corresponds to a baffle positioned horizontally. Placing a baffle near the top of the sphere for high Ra number cases can lead to heat transfer enhancement that is linked to disturbance of the thermal boundary layer. With isothermal baffles, heat transfer enhancement is achieved for a baffle placed near the bottom of the sphere due to interaction of the counterclockwise rotating vortex and the stratified layer. For some high Ra cases, strong fluctuations of the flow and thermal fields indicating departure from the pseudosteady-state were observed.


Author(s):  
Degan Gerard ◽  
Sokpoli Amavi Ernest ◽  
Akowanou Djidjoho Christian ◽  
Vodounnou Edmond Claude

This research was devoted to the analytical study of heat transfer by natural convection in a vertical cavity, confining a porous medium, and containing a heat source. The porous medium is hydrodynamically anisotropic in permeability whose axes of permeability tensor are obliquely oriented relative to the gravitational vector and saturated with a Newtonian fluid. The side walls are cooled to the temperature  and the horizontal walls are kept adiabatic. An analytical solution to this problem is found for low Rayleigh numbers by writing the solutions of mathematical model in polynomial form of degree n of the Rayleigh number. Poisson equations obtained are solved by the modified Galerkin method. The results are presented in term of streamlines and isotherms. The distribution of the streamlines and the temperature fields are greatly influenced by the permeability anisotropy parameters and the thermal conductivity. The heat transfer decreases considerably when the Rayleigh number increases.


2019 ◽  
Vol 20 (1) ◽  
pp. 229-244
Author(s):  
Mehdi Ahmadi ◽  
Seyed Ali Agha Mirjalily ◽  
Seyed Amir Abbas Oloomi

ABSTRACT: This study is conducted to investigate turbulent natural convection flow in an enclosure with thermal sources using the low-Reynolds number (LRN) k-? model. This enclosure has a cold source with temperature Tc and a hot source with temperature Th as thermal sources, other walls of the enclosure are adiabatic. The aim of this study is to predict the effect of change in Rayleigh number, repositioning of cold and hot sources, and thermal sources aspect ratio on the flow field, temperature, and rate of heat transfer. To achieve this aim, the equations of continuity, momentum, energy, turbulent kinetic energy, and kinetic energy dissipation are employed in the case of 2D turbulence with constant thermo-physical properties except the density in the buoyancy term (Boussinesq approximation). To numerically solve these equations, the finite volume method and SIMPLE algorithm are used. According to the modeling results, the most optimal temperature distribution in the enclosure is seen when the hot source is below the cold source. With decreasing distance between hot and cold sources, heat transfer rate increases. The maximal heat transfer rate is derived via study of the heating sources aspect ratio. In constant positions of cold and hot sources on a wall, the heat transfer rate increases with increasing Rayleigh number (Ra=109-1011). ABSTAK: Kajian ini dijalankan bagi mengkaji perubahan semula jadi aliran perolakan dalam tempat tertutup dengan sumber haba menggunakan model k-? nombor Reynolds-rendah (LRN). Bekas tertutup ini mempunyai dua sumber haba iaitu sumber sejuk dengan suhu Tc dan sumber panas dengan suhu Th, manakala dinding lain bekas ini adalah adiabatik. Tujuan kajian ini adalah bagi mengesan perubahan nombor Rayleigh, mengubah sumber sejuk dan panas dan nisbah sumber haba kepada kawasan aliran, suhu dan halaju perubahan haba. Bagi mencapai tujuan tersebut, persamaan sambungan, momentum, tenaga, tenaga kinetik perolakan, dan pengurangan tenaga kinetik telah dilaksanakan dalam kes perolakan 2D dengan sifat fizikal-haba berterusan (malar) kecuali isipadu terma keapungan (anggaran Boussinesq). Bagi menyelesaikan persamaan ini secara berangka, kaedah isipadu terhad dan algorithma MUDAH telah digunakan. Berdasarkan keputusan model, suhu distribusi optimal dalam bekas tertutup dilihat apabila sumber panas adalah kurang daripada sumber sejuk. Dengan pengurangan jarak antara sumber panas dan sejuk, kadar pertukaran haba meningkat. Kadar pertukaran haba maksima telah diperoleh melalui kajian nisbah  aspek sumber pemanasan. Kadar pertukaran haba bertambah dengan bertambahnya nombor Rayleigh  (Ra=109-1011), pada posisi tetap sumber sejuk dan panas pada dinding bekas.


Sign in / Sign up

Export Citation Format

Share Document