Protection of Seismic Structures Using Passive and Semi-Active Friction Typed Multiple Tuned Mass Dampers
Although the design and applications of linear tuned mass damper (TMD) systems are well developed, nonlinear TMD systems are still developing. In this paper, the application of multiple semi-active friction tuned mass dampers (SAF-MTMD) for response control of a multistory structure under seismic excitation is investigated. The friction forces of the SAF-MTMD are controllable. A non-sticking friction (NSF) controller, which is able to keep each of the TMD activated and in its slip state throughout an earthquake with arbitrary intensity, was conducted. A parametric study is performed to investigate the effectiveness of SAF-MTMD. The seismic performance of the SAF-MTMD is also compared with the single and multiple passive friction tuned mass dampers (PF-TMD/PF-MTMD). The numerical result shows that the SAF-MTMD is superior to PF-MTMD in reducing the response of the primary structure under the seismic excitation.