scholarly journals Safety and parents´ acceptance of ultrasound contrast agents in children and adolescents – contrast enhanced voiding urosonography and contrast enhanced ultrasound

2021 ◽  
Author(s):  
Josefina Seelbach ◽  
Paul C Krüger ◽  
Matthias Waginger ◽  
Diane M Renz ◽  
Hans-Joachim Mentzel

Aims: To evaluate the safety of the contrast enhanced voiding urosonography (ceVUS) and contrast enhanced ultrasound (CEUS) in children and adolescence and to receive data about parents’ acceptance of intravesical and intravenous application of sulfur hexafluoride.Material and methods: In this prospective, single centre study conducted over a 1 year study period, parents of 56 children (f/m=32/24; mean age 3.1 years; range 3 weeks - 15.9 years) with ceVUS and of 30 children (f/m=15/15; mean age 10.5 years; range 2 months - 17.7 years) with CEUS agreed to be included. A standardized telephone survey about the acceptance of the parents during and after the procedure as well as the adverse events (AE) were conducted within three days of the examination.Results: The parents would agree with the use of both ceVUS and CEUS as a diagnostic tool again in 96% (54/56) or 100% (30/30) of the cases, respectively and 92.9% (52/56) would prefer ceVUS to voiding cystourethrography (VCUG). In addition, 83.3% (25/30) would prefer CEUS to CT and 73.3% (22/30) would prefer CEUS to MRI. AE were reported in 3.6% after ceVUS (2/56; skin rash, mild fever) and in 3.3% after CEUS (1/30; vomiting). AE were subacute and self‑limited.Conclusions: The vast majority of parents prefer ceVUS and CEUS to VCUG, CT or MRI because of the safety profile of the contrast agent and diagnostic accuracy.

2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
John R. Eisenbrey ◽  
Anush Sridharan ◽  
Ji-Bin Liu ◽  
Flemming Forsberg

Nonlinear contrast-enhanced ultrasound imaging schemes strive to suppress tissue signals in order to better visualize nonlinear signals from blood-pooling ultrasound contrast agents. Because tissue does not generate a subharmonic response (i.e., signal at half the transmit frequency), subharmonic imaging has been proposed as a method for isolating ultrasound microbubble signals while suppressing surrounding tissue signals. In this paper, we summarize recent advances in the use of subharmonic imagingin vivo. These advances include the implementation of subharmonic imaging on linear and curvilinear arrays, intravascular probes, and three-dimensional probes for breast, renal, liver, plaque, and tumor imaging.


Author(s):  
Daohui Yang ◽  
Dansong Wang ◽  
Yijie Qiu ◽  
Xiaofan Tian ◽  
Dan Zuo ◽  
...  

AIM: Preoperative suspicion of malignancy in nonfunctioning pancreatic neuroendocrine tumors (pNETs) is mostly based on tumor size. We retrospectively analyzed the contrast enhanced ultrasound (CEUS) features of a series of histopathologically proved nonfunctioning pNETs. METHODS: In this retrospective study, 37 surgery and histologically proved nonfunctioning pNETs were included. All pNETs lesions were incidentally detected by transabdominal ultrasound. B mode ultrasound (BMUS) and CEUS features were reviewed and analyzed. 52 histopathologically proved pancreatic ductal adenocarcinoma (PDACs) lesions were included as a control group. RESULTS: All nonfunctioning pNETs patients showed no typical clinical symptoms. No significant differences were observed in size, echogenicity or internal color flow imaging signal between pNETs and PDAC patients (P >  0.05). Most of nonfunctioning pNETs showed a well-defined tumor margin. The presence of pancreatic duct dilatation was less frequently observed in nonfunctioning pNETs patients (P <  0.05). After injection of ultrasound contrast agents, homogeneous enhancement was more commonly observed in nonfunctioning pNETs group (P <  0.05). During arterial phase of CEUS, most of nonfunctioning pNETs were hyper- or isoenhanced (32/37, 86.5%), whereas most of PDACs were hypoenhanced (34/52, 65.4%) (P <  0.05). Nonenhanced necrosis area was more commonly detected in PDACs (P = 0.012). CONCLUSIONS: CEUS features are helpful for preoperative non-invasive differential diagnosis of nonfunctioning pNETs, assisting further clinical decision-making process.


Sensors ◽  
2020 ◽  
Vol 20 (12) ◽  
pp. 3584
Author(s):  
Huang-Chen Lin ◽  
Shyh-Hau Wang

The assessment of microvascular perfusion is essential for the diagnosis of a specific muscle disease. In comparison with the current available medical modalities, the contrast-enhanced ultrasound imaging is the simplest and fastest means for probing the tissue perfusion. Specifically, the perfusion parameters estimated from the ultrasound time-intensity curve (TIC) and statistics-based time–Nakagami parameter curve (TNC) approaches were found able to quantify the perfusion. However, due to insufficient tolerance on tissue clutters and subresolvable effects, these approaches remain short of reproducibility and robustness. Consequently, the window-modulated compounding (WMC) Nakagami parameter ratio imaging was proposed to alleviate these effects, by taking the ratio of WMC Nakagami parameters corresponding to the incidence of two different acoustic pressures from an employed transducer. The time–Nakagami parameter ratio curve (TNRC) approach was also developed to estimate perfusion parameters. Measurements for the assessment of muscle perfusion were performed from the flow phantom and animal subjects administrated with a bolus of ultrasound contrast agents. The TNRC approach demonstrated better sensitivity and tolerance of tissue clutters than those of TIC and TNC. The fusion image with the WMC Nakagami parameter ratio and B-mode images indicated that both the tissue structures and perfusion properties of ultrasound contrast agents may be better discerned.


Neurosurgery ◽  
2014 ◽  
Vol 74 (5) ◽  
pp. 542-552 ◽  
Author(s):  
Francesco Prada ◽  
Alessandro Perin ◽  
Alberto Martegani ◽  
Luca Aiani ◽  
Luigi Solbiati ◽  
...  

Abstract BACKGROUND: Contrast-enhanced ultrasound (CEUS) is a dynamic and continuous modality that offers a real-time, direct view of vascularization patterns and tissue resistance for many organs. Thanks to newer ultrasound contrast agents, CEUS has become a well-established, live-imaging technique in many contexts, but it has never been used extensively for brain imaging. The use of intraoperative CEUS (iCEUS) imaging in neurosurgery is limited. OBJECTIVE: To provide the first dynamic and continuous iCEUS evaluation of a variety of brain lesions. METHODS: We evaluated 71 patients undergoing iCEUS imaging in an off-label setting while being operated on for different brain lesions; iCEUS imaging was obtained before resecting each lesion, after intravenous injection of ultrasound contrast agent. A semiquantitative, offline interobserver analysis was performed to visualize each brain lesion and to characterize its perfusion features, correlated with histopathology. RESULTS: In all cases, the brain lesion was visualized intraoperatively with iCEUS. The afferent and efferent blood vessels were identified, allowing evaluation of the time and features of the arterial and venous phases and facilitating the surgical strategy. iCEUS also proved to be useful in highlighting the lesion compared with standard B-mode imaging and showing its perfusion patterns. No adverse effects were observed. CONCLUSION: Our study is the first large-scale implementation of iCEUS in neurosurgery as a dynamic and continuous real-time imaging tool for brain surgery and provides the first iCEUS characterization of different brain neoplasms. The ability of CEUS to highlight and characterize brain tumor will possibly provide the neurosurgeon with important information anytime during a surgical procedure.


2003 ◽  
Vol 44 (3) ◽  
pp. 265-268
Author(s):  
M. Uhl ◽  
J. Kromeier ◽  
L.-B. Zimmerhackl ◽  
K. Darge

Purpose: To compare the diagnostic accuracy of contrast-enhanced voiding urosonography (VUS) and voiding cystourethrography (VCUG) during simultaneous performance of both examinations. Material and Methods: A total of 24 children, 16 girls and 8 boys, with a mean age of 3.5 years referred for reflux examination were recruited for the study. After transurethral bladder catheterization, radiographic contrast medium, followed directly by the US contrast medium, were administered. Fluoroscopic VCUG and VUS were carried out concurrently in the same patient. When 1 kidney was scanned by ultrasound, fluoroscopy was performed on the contralateral side. Results: In 19 of the 47 kidney-ureter-units (KUU) vesicoureteral reflux (VUR) was detected. In 16 units the reflux was detected by both VCUG and VUS. In 3 KUUs the reflux was detected only at VCUG. All 3 cases were grade 1. Taking the VCUG as the reference standard, VUS had 84% sensitivity, 100% specificity, 100% and 90% positive and negative predictive values, respectively. Conclusion: A dependable comparison could be achieved by performing VCUG and VUS at the same time and under the same conditions. It reconfirmed that VUS is reliable in the exclusion or verification of reflux.


2012 ◽  
Vol 33 (04) ◽  
pp. 344-351 ◽  
Author(s):  
C. Dietrich ◽  
M. Averkiou ◽  
J.-M. Correas ◽  
N. Lassau ◽  
E. Leen ◽  
...  

AbstractDynamic Contrast Enhanced Ultrasound (DCE-US) is an imaging technique that utilizes microbubble contrast agents in diagnostic ultrasound. The EFSUMB guidelines published in 2004, updated in 2008 and 2011 focused on the use of DCE-US, including essential technical requirements, training, investigational procedures and steps, guidance on image interpretation, established and recommended clinical indications and safety considerations. However the quantification of images acquired with ultrasound contrast agents (UCAs) is not discussed in the guidelines. The purpose of this EFSUMB document is to provide some recommendations and descriptions of the quantification of ultrasound images, technical requirements for analysis of time-intensity curves (TICs), methodology for data analysis, and interpretation of the results.


2020 ◽  
Vol 41 (05) ◽  
pp. 562-585 ◽  
Author(s):  
Christoph F. Dietrich ◽  
Christian Pállson Nolsøe ◽  
Richard G. Barr ◽  
Annalisa Berzigotti ◽  
Peter N Burns ◽  
...  

AbstractThe present, updated document describes the fourth iteration of recommendations for the hepatic use of contrast enhanced ultrasound (CEUS), first initiated in 2004 by the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB). The previous updated editions of the guidelines reflected changes in the available contrast agents and updated the guidelines not only for hepatic but also for non-hepatic applications.The 2012 guideline requires updating as previously the differences of the contrast agents were not precisely described and the differences in contrast phases as well as handling were not clearly indicated. In addition, more evidence has been published for all contrast agents. The update also reflects the most recent developments in contrast agents, including the United States Food and Drug Administration (FDA) approval as well as the extensive Asian experience, to produce a truly international perspective.These guidelines and recommendations provide general advice on the use of ultrasound contrast agents (UCA) and are intended to create standard protocols for the use and administration of UCA in liver applications on an international basis to improve the management of patients.


Author(s):  
Francesco Maria Drudi ◽  
Flavia Angelini ◽  
Michele Bertolotto ◽  
Antonio Granata ◽  
Giovanni Battista Di Pierro ◽  
...  

AbstractVesicoureteral reflux (VUR) is a common urological complication in renal transplant patients. The aim of this study is to evaluate the performance of contrast-enhanced voiding urosonography (CEvUS) in the diagnosis and classification of reflux into the renal allograft, to evaluate and classify VUR into the allograft using voiding cystourethrography (VCUG) and CEvUS, to compare the two methods, and to propose a new classification of reflux into the allograft based on CEvUS and VCUG assessment, in line with the international reflux grading system. Materials and Methods From January 2017 to July 2019, 84 kidney transplant patients were enrolled. All patients underwent VCUG and CEvUS. Results In 76 cases there was agreement between VCUG and CEvUS (90 %) (Kappa = 0.7). The sensitivity of CEvUS using VCUG as the gold standard was 90 %, and the specificity was 92 %. Of the 7 cases diagnosed by VCUG and not by CEvUS, 6 were grade 1 and 1 was grade 2. Conclusion Transplant patients with reflux symptoms should undergo CEvUS. If the outcome is negative, VCUG should be performed. The classification that we propose is better suited to describe VUR in transplant patients, because it is simpler and takes into account whether reflux occurs not only during urination but also when the bladder is relaxed.


Sign in / Sign up

Export Citation Format

Share Document