Practical measurement of cell-phone camera lens focal length

Author(s):  
Thomas D. Milster ◽  
William P. Kuhn
2021 ◽  
Vol 2021 (1) ◽  
Author(s):  
Xiang Li ◽  
Jianzheng Liu ◽  
Jessica Baron ◽  
Khoa Luu ◽  
Eric Patterson

AbstractRecent attention to facial alignment and landmark detection methods, particularly with application of deep convolutional neural networks, have yielded notable improvements. Neither these neural-network nor more traditional methods, though, have been tested directly regarding performance differences due to camera-lens focal length nor camera viewing angle of subjects systematically across the viewing hemisphere. This work uses photo-realistic, synthesized facial images with varying parameters and corresponding ground-truth landmarks to enable comparison of alignment and landmark detection techniques relative to general performance, performance across focal length, and performance across viewing angle. Recently published high-performing methods along with traditional techniques are compared in regards to these aspects.


Laser Physics ◽  
2021 ◽  
Vol 32 (1) ◽  
pp. 015001
Author(s):  
Majid Babaiy Tooski ◽  
Abbas Maleki ◽  
Abdolah Eslami Majd ◽  
Hassan Ebadian

Abstract In this paper, a Tm:fiber laser pumped Ho:YLF laser is simulated. The absorption efficiency, optimum crystal length, and optical resonator are analytically studied and simulated using LASCAD software, and the atomic-level degeneracies are considered in evaluating the absorption efficiency. In this way, the absorption efficiencies of 65% and 87% are obtained for single-pass 30 mm Ho:YLF crystal with doping concentration 0.5% and 1% respectively. These calculated efficiencies are verified by our experimental measurements and they coincide with acceptable errors. To estimate a proper length for the Ho:YLF crystal with specified doping concentration, the up-conversion, and the reabsorption effects are considered. As a result, we find the 30 mm length crystal is suited for reducing the absorption threshold and prohibiting reabsorption while saturation is controlled. The threshold power and slope efficiency for 65 W pumped powers are calculated by LASCAD software, and the thermal lens focal length of −665 mm is obtained. For a nearly constant beam width inside the cavity and suitable beam overlap efficiency, a concave-concave configuration is chosen for the optical resonator. In the continuous-wave operation, the output power is funded to be 38.4 W and the slope efficiency would be 66%.


Applied laser ◽  
2013 ◽  
Vol 33 (2) ◽  
pp. 212-215
Author(s):  
许江华 Xu Jianghua ◽  
朱岚 Zhu Lan ◽  
陈家璧 Chen Jiabi ◽  
庄松林 Zhuang Songlin

1996 ◽  
Vol 50 (7) ◽  
pp. 849-860 ◽  
Author(s):  
Thomas F. Cooney ◽  
H. Trey Skinner ◽  
S. M. Angel

We compare relative performances of flat-tipped, beveled (two-fiber and six-around-one), and single-lensed focused fiber-optic Raman probes and, where feasible, evaluate the utility of optical filters for reducing fiber background. The sensitivity profile of each probe is determined by measuring the relative intensity of light backscattered off a flat surface as a function of distance from the probe tip. The experimental results are compared with a simple light-cone-overlap model incorporating fiber numerical aperture, fiber and immersion medium refractive indices, separation between excitation and collection fibers, number of fibers, and fiber bevel angle and/or lens focal length. The model and sensitivity profiles are used to interpret the sampling regions for Raman spectra obtained by using each of the probes with a clear, transparent sample (single-crystal sparry calcite), a white, partially transparent sample (acetaminophen tablet), and a set of organic liquids of varying refractive index. The sensitivity of the tested commercial lensed probe drops off symmetrically about the focal point. For both solid samples, the intensity of fiber background follows a profile determined primarily by laser backscattering off the surface, whereas the sample Raman signal follows a profile dependent upon sampling depth.


2013 ◽  
Vol 765-767 ◽  
pp. 780-784 ◽  
Author(s):  
Zhen Feng Yang ◽  
Wen Dan Miao ◽  
Zhen Jun Yang ◽  
Shu Min Zhang

The fractional Fourier transform (FRFT) of a new type of laser beams called the hypergeometric-Gaussian beam (HyGGB) is investigated in detail. The analytical expression for the FRFT of a HyGGB is derived. The properties of a HyGGB in the FRFT plane with different parameters are illustrated. The results show that the intensity distribution of a HyGGB in the FRFT plane strongly depends on the fractional order, the lens focal length and the initial beam width.


1978 ◽  
Author(s):  
Charles R. Hayslett ◽  
William H. Swantner ◽  
Richard A. Buchroeder
Keyword(s):  

2014 ◽  
Vol 31 (5) ◽  
pp. 1018 ◽  
Author(s):  
Sonia Melle ◽  
Oscar G. Calderón ◽  
Ana Egatz-Gómez ◽  
E. Cabrera-Granado ◽  
F. Carreño ◽  
...  

2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Sergio Pérez-López ◽  
José Miguel Fuster ◽  
Igor V. Minin ◽  
Oleg V. Minin ◽  
Pilar Candelas

Abstract In this work, we present a configurable spherical lens for underwater focusing applications, which consists on a hollow ABS container filled with a liquid mixture. Two miscible liquids with different sound speeds are required to implement this novel configurable lens. We show that by adjusting the mixing ratio between the volumes of both liquids, the sound speed of the liquid mixture can be accurately selected. This results in a modification of the acoustic jet properties and a continuous tuning on the lens focal length. This procedure can be fully automatized providing a dynamic control mechanism that can shift the lens focal length to any desired value inside a continuous range in both directions. Depending on the acoustic properties of the selected liquids, subwavelength resolution or even beyond the diffraction limit resolution can be achieved. We provide experimental measurements for ethanol-water mixtures achieving subwavelength resolution for a certain focal length ranging between 34.6 and 42.8 mm.


Sign in / Sign up

Export Citation Format

Share Document