Photonic liquid crystals on a single substrate for label-free protein assays

2021 ◽  
Author(s):  
Mon-Juan Lee ◽  
Chao-Ping Pai ◽  
Po-Chang Wu ◽  
Wei Lee
Biosensors ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 374
Author(s):  
Po-Chang Wu ◽  
Chao-Ping Pai ◽  
Mon-Juan Lee ◽  
Wei Lee

A liquid crystal (LC)-based single-substrate biosensor was developed by spin-coating an LC thin film on a dimethyloctadecyl[3-(trimethoxysilyl)propyl]ammonium chloride (DMOAP)-decorated glass slide. Compared with the conventional sandwiched cell configuration, the simplified procedure for the preparation of an LC film allows the film thickness to be precisely controlled by adjusting the spin rate, thus eliminating personal errors involved in LC cell assembly. The limit of detection (LOD) for bovine serum albumin (BSA) was lowered from 10−5 g/mL with a 4.2-μm-thick sandwiched cell of the commercial LC E7 to 10−7 g/mL with a 4.2-μm-thick spin-coated E7 film and further to 10−8 g/mL by reducing the E7 film thickness to 3.4 μm. Moreover, by exploiting the LC film of the highly birefringent nematic LC HDN in the immunodetection of the cancer biomarker CA125, an LOD comparable to that determined with a sandwiched HDN cell was achieved at 10−8 g/mL CA125 using a capture antibody concentration an order of magnitude lower than that in the LC cell. Our results suggest that employing spin-coated LC film instead of conventional sandwiched LC cell provides a more reliable, reproducible, and cost-effective single-substrate platform, allowing simple fabrication of an LC-based biosensor for sensitive and label-free protein detection and immunoassay.


Author(s):  
Kazuhiro Takahashi ◽  
Ryo Ozawa ◽  
Hiroki Oyama ◽  
Masato Futagawa ◽  
Fumihiro Dasai ◽  
...  

2019 ◽  
Vol 7 (32) ◽  
pp. 4933-4939
Author(s):  
Friederike Schlüter ◽  
Bart Jan Ravoo ◽  
Fabio Rizzo

New sensors for the recognition of proteins on glass and quartz surfaces were developed in a straightforward layer-by-layer deposition process.


Biosensors ◽  
2020 ◽  
Vol 10 (11) ◽  
pp. 158
Author(s):  
Iris Celebi ◽  
Matthew T. Geib ◽  
Elisa Chiodi ◽  
Nese Lortlar Ünlü ◽  
Fulya Ekiz Kanik ◽  
...  

Protein microarrays have gained popularity as an attractive tool for various fields, including drug and biomarker development, and diagnostics. Thus, multiplexed binding affinity measurements in microarray format has become crucial. The preparation of microarray-based protein assays relies on precise dispensing of probe solutions to achieve efficient immobilization onto an active surface. The prohibitively high cost of equipment and the need for trained personnel to operate high complexity robotic spotters for microarray fabrication are significant detriments for researchers, especially for small laboratories with limited resources. Here, we present a low-cost, instrument-free dispensing technique by which users who are familiar with micropipetting can manually create multiplexed protein assays that show improved capture efficiency and noise level in comparison to that of the robotically spotted assays. In this study, we compare the efficiency of manually and robotically dispensed α-lactalbumin probe spots by analyzing the binding kinetics obtained from the interaction with anti-α-lactalbumin antibodies, using the interferometric reflectance imaging sensor platform. We show that the protein arrays prepared by micropipette manual spotting meet and exceed the performance of those prepared by state-of-the-art robotic spotters. These instrument-free protein assays have a higher binding signal (~4-fold improvement) and a ~3-fold better signal-to-noise ratio (SNR) in binding curves, when compared to the data acquired by averaging 75 robotic spots corresponding to the same effective sensor surface area. We demonstrate the potential of determining antigen-antibody binding coefficients in a 24-multiplexed chip format with less than 5% measurement error.


Sign in / Sign up

Export Citation Format

Share Document