Fluorescence-based planar waveguide biosensors

Author(s):  
Gert L. Duveneck
Keyword(s):  
1999 ◽  
Author(s):  
C. Joseph ◽  
D. Campbell ◽  
J. Suggs ◽  
J. Moore ◽  
N. Hartman
Keyword(s):  

Electronics ◽  
2021 ◽  
Vol 10 (11) ◽  
pp. 1311
Author(s):  
Giovanni Andrea Casula ◽  
Giuseppe Mazzarella ◽  
Giorgio Montisci ◽  
Giacomo Muntoni

Planar waveguide slot arrays (WSAs) have been used since 1940 and are currently used as performing antennas for high frequencies, especially in applications such as communication and RADAR systems. We present in this work a review of the most typical waveguide slot array configurations proposed in the literature, describing their main limitations and drawbacks along with possible effective countermeasures. Our attention has been focused mainly on the improved available design techniques to obtain high performance WSAs. In particular, the addressed topics have been reported in the following. Partially filled WSAs, or WSAs covered with single or multilayer dielectric slabs, are discussed. The most prominent second-order effects in the planar array feeding network are introduced and accurately modeled. The attention is focused on the T-junction feeding the array, on the effect of interaction between each slot coupler of the feeding network and the radiating slots nearest to this coupler, and on the waveguide bends. All these effects can critically increase the first sidelobes if compared to the ideal case, causing a sensible worsening in the performance of the array.


Photonics ◽  
2021 ◽  
Vol 8 (6) ◽  
pp. 199
Author(s):  
Yu-Cheng Lin ◽  
Liang-Yü Chen

The generation of lossy mode resonances (LMR) with a metallic oxide film deposited on an optical fiber has attracted the attention of many applications. However, an LMR-based optical fiber sensor is frangible, and therefore it does not allow control of the temperature and is not suited to mass production. This paper aims to develop a temperature-controlled lossy mode resonance (TC-LMR) sensor on an optical planar waveguide with an active temperature control function in which an ITO film is not only used as the LMR resonance but also to provide the heating function to achieve the benefits of compact size and active temperature control. A simple flat model about the heat transfer mechanism is proposed to determine the heating time constant for the applied voltages. The TC-LMR sensor is evaluated experimentally for refractive index measurement using a glycerol solution. The heating temperature functions relative to the controlled voltages for water and glycerol are obtained to verify the performance of the TC-LMR sensor. The TC-LMR sensor is a valuable sensing device that can be used in clinical testing and point of care for programming heating with precise temperature control.


1999 ◽  
Vol 11 (7) ◽  
pp. 809-811 ◽  
Author(s):  
Xuesong Dong ◽  
P. LiKamWa ◽  
J. Loehr ◽  
R. Kaspi

2004 ◽  
Vol 70 (4) ◽  
Author(s):  
Jan Peřina ◽  
Concita Sibilia ◽  
Daniela Tricca ◽  
Mario Bertolotti

2014 ◽  
Vol 39 (7) ◽  
pp. 1953 ◽  
Author(s):  
Krzysztof M. Nowak ◽  
Takeshi Ohta ◽  
Takashi Suganuma ◽  
Junichi Fujimoto ◽  
Hakaru Mizoguchi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document