scholarly journals Technical Note: A treatment plan comparison between dynamic collimation and a fixed aperture during spot scanning proton therapy for brain treatment

2016 ◽  
Vol 43 (8Part1) ◽  
pp. 4693-4699 ◽  
Author(s):  
Blake Smith ◽  
Edgar Gelover ◽  
Alexandra Moignier ◽  
Dongxu Wang ◽  
Ryan T. Flynn ◽  
...  
2015 ◽  
Vol 42 (6Part14) ◽  
pp. 3374-3374
Author(s):  
B Smith ◽  
E Gelover ◽  
D Wang ◽  
A Moignier ◽  
R Flynn ◽  
...  

2021 ◽  
Vol 18 ◽  
pp. 11-18
Author(s):  
Lia Barbosa Valdetaro ◽  
Ellen Marie Høye ◽  
Peter Sandegaard Skyt ◽  
Jørgen Breede Baltzer Petersen ◽  
Peter Balling ◽  
...  

2016 ◽  
Vol 17 (5) ◽  
pp. 366-376 ◽  
Author(s):  
Xin Wang ◽  
Falk Poenisch ◽  
Narayan Sahoo ◽  
Ronald X. Zhu ◽  
MingFwu Lii ◽  
...  

2020 ◽  
Vol 152 ◽  
pp. S752-S753
Author(s):  
J. Gajewski ◽  
A. Schiavi ◽  
N. Krah ◽  
V. Patera ◽  
G. Vilches-Freixas ◽  
...  

Diagnostics ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1117
Author(s):  
Sabina Vennarini ◽  
Dante Amelio ◽  
Stefano Lorentini ◽  
Giovanna Stefania Colafati ◽  
Antonella Cacchione ◽  
...  

Chordoma in pediatric patients is very rare. Proton therapy has become a gold standard in the treatment of these neoplasms, as high dose escalation can be achieved regarding the target while maximizing the sparing of the healthy tissues near the tumor. The aim of the work was to assess the evolution of morphological sequences during treatment using T1/T2-weighted magnetic resonance imaging (MRI) for the early response assessment of a classic chordoma of the skull base in a pediatric patient who had undergone surgical excision. Our results demonstrated a significant quantitative reduction in the residual nodule component adhered to the medullary bulb junction, with an almost complete recovery of normal anatomy at the end of the irradiation treatment. This was mainly shown in the T2-weighted MRI. On the other hand, the classic component of the lesion was predominantly present and located around the tooth of the axis. The occipital condyles were morphologically and dimensionally stable for the entire irradiation period. In conclusion, the application of this type of monitoring methodology, which is unusual during the administration of a proton treatment for chordoma, highlighted the unexpected early response of the disease. At the same time, it allowed the continuous assessment of the reliability of the treatment plan.


2019 ◽  
Vol 6 (2) ◽  
pp. 31-41
Author(s):  
Jiankui Yuan ◽  
David Mansur ◽  
Min Yao ◽  
Tithi Biswas ◽  
Yiran Zheng ◽  
...  

ABSTRACT Purpose: We developed an integrated framework that employs a full Monte Carlo (MC) model for treatment-plan simulations of a passive double-scattering proton system. Materials and Methods: We have previously validated a virtual machine source model for full MC proton-dose calculations by comparing the percentage of depth-dose curves, spread-out Bragg peaks, and lateral profiles against measured commissioning data. This study further expanded our previous work by developing an integrate framework that facilitates its clinical use. Specifically, we have (1) constructed patient-specific applicator and compensator numerically from the plan data and incorporated them into the beamline, (2) created the patient anatomy from the computed tomography image and established the transformation between patient and machine coordinate systems, and (3) developed a graphical user interface to ease the whole process from importing the treatment plan in the Digital Imaging and Communications in Medicine format to parallelization of the MC calculations. End-to-end tests were performed to validate the functionality, and 3 clinical cases were used to demonstrate clinical utility of the framework. Results: The end-to-end tests demonstrated that the framework functioned correctly for all tested functionality. Comparisons between the treatment planning system calculations and MC results in 3 clinical cases revealed large dose difference up to 17%, especially in the beam penumbra and near the end of beam range. The discrepancy likely originates from a variety of sources, such as the dose algorithms, modeling of the beamline, and the dose metric. The agreement for other regions was acceptable. Conclusion: An integrated framework was developed for full MC simulations of double-scattering proton therapy. It can be a valuable tool for dose verification and plan evaluation.


2021 ◽  
Vol 20 ◽  
pp. 153303382110330
Author(s):  
Chunbo Liu ◽  
Meng Wei Ho ◽  
Jiyeon Park ◽  
Wen Chien Hsi ◽  
Xiaoying Liang ◽  
...  

Purpose: To commission MCsquare (a multi-cores CPU-based dose calculation engine) for pencil beam scanning (PBS) proton therapy, integrate it into RayStation treatment plan system (TPS) to create a dedicated platform for fast independent dose verification. Method: A MCsquare-based independent dose verification platform (MC2InRS) was developed to realize automatic dose re-calculation for clinical use, including data preparation, dose calculation, 2D/3D gamma analysis. MCsquare was commissioned based on in-air lateral dose profiles, integrated depth dose, and the absolute dose of different beam energies for Proteus®ONE. MC2InRS was validated with measurement data using various targets and depths in a water phantom. This study also investigated 15 clinical cases to demonstrate the feasibility and effectiveness of MC2InRS platform in clinic practice. Results: Between simulation and measurement, the distal range differences at 80% (R80) and 20% (R20) dose levels for each energy were below 0.05 mm, and 0.1 mm, respectively, and the absolute dose differences were below 0.5%. 29 out of 36 QA planes reached a 100% gamma passing rate (GPR) for 2%/2mm criteria, and a minimum of 98.3% gamma was obtained in water phantom between simulation and measurement. For the 15 clinical cases investigated, the average 2D GPR (2%/2mm) was 95.4%, 99.3% for MCsquare vs. measurement, MCsquare vs. TPS, respectively. The average 3D GPR (2%/2mm) was 98.9%, 95.3% for MCsquare vs. TPS in water, and computed tomography (CT), respectively. Conclusion: MC2InRS, a fast, independent dose verification platform, has been developed to perform dose verification with high accuracy and efficiency for Pencil Bream Scanning (PBS). Its potential to be applied in routine clinical practice has also been discussed.


2021 ◽  
Vol 11 ◽  
Author(s):  
Christian Bäumer ◽  
Sandija Plaude ◽  
Dalia Ahmad Khalil ◽  
Dirk Geismar ◽  
Paul-Heinz Kramer ◽  
...  

Proton therapy makes use of the favorable depth-dose distribution with its characteristic Bragg peak to spare normal tissue distal of the target volume. A steep dose gradient would be desired in lateral dimensions, too. The widespread spot scanning delivery technique is based, however, on pencil-beams with in-air spot full-widths-at-half-maximum of typically 1 cm or more. This hampers the sparing of organs-at-risk if small-scale structures adjacent to the target volume are concerned. The trimming of spot scanning fields with collimating apertures constitutes a simple measure to increase the transversal dose gradient. The current study describes the clinical implementation of brass apertures in conjunction with the pencil-beam scanning delivery mode at a horizontal, clinical treatment head based on commercial hardware and software components. Furthermore, clinical cases, which comprised craniopharyngiomas, re-irradiations and ocular tumors, were evaluated. The dosimetric benefits of 31 treatment plans using apertures were compared to the corresponding plans without aperture. Furthermore, an overview of the radiation protection aspects is given. Regarding the results, robust optimization considering range and setup uncertainties was combined with apertures. The treatment plan optimizations followed a single-field uniform dose or a restricted multi-field optimization approach. Robustness evaluation was expanded to account for possible deviations of the center of the pencil-beam delivery and the mechanical center of the aperture holder. Supplementary apertures improved the conformity index on average by 15.3%. The volume of the dose gradient surrounding the PTV (evaluated between 80 and 20% dose levels) was decreased on average by 17.6%. The mean dose of the hippocampi could be reduced on average by 2.9 GyRBE. In particular cases the apertures facilitated a sparing of an organ-at-risk, e.g. the eye lens or the brainstem. For six craniopharyngioma cases the inclusion of apertures led to a reduction of the mean dose of 1.5 GyRBE (13%) for the brain and 3.1 GyRBE (16%) for the hippocampi.