SOUND PROCESSING APPARATUS, SOUND PROCESSING METHOD, AND SOUND PROCESSING PROGRAM

2013 ◽  
Vol 134 (5) ◽  
pp. 3962
Author(s):  
Saki Hanai ◽  
Mitsuhiro Suzuki
2013 ◽  
Vol 134 (1) ◽  
pp. 737
Author(s):  
Matthijs J. P. Killian

2013 ◽  
Vol 303-306 ◽  
pp. 650-653
Author(s):  
Sirimonpak Sutdipong ◽  
Khanchai Tunlasakun

This research presents the design and development of the heart sound monitor for biomedical instrumentation which can be worked with a personal computer. The prototype will receive the heart sound via the condenser microphone built-in the stethoscope. The condenser microphone will be conversed the air pressure from heart beats to electrical signal that signal will transformed to computer via sound card. The sound card will be conversed the analog signal to digital signal for process by heart sound processing program developed by LabVIEW program. The signal will be analyzed with short time Fourier transforms in heart sound processing program by graphical user interface. The user is able to select a band pass of signal for filter and choose the frequency spectrum of heart sound for display. The output database from this prototype is necessary for Medical Education or Clinical Practice.


2013 ◽  
Vol 680 ◽  
pp. 644-648
Author(s):  
Khanchai Tunlasakun

This research presents the design and development of the heart sound monitor for bio-signal learning which can be worked with a personal computer. The prototype will receive the heart sound via the condenser microphone built-in the stethoscope. The condenser microphone will be conversed the air pressure from heart beats to electrical signal that signal will transformed to computer via sound card. The sound card will be conversed the analog signal to digital signal for process by heart sound processing program developed by LabVIEW program. The signal will be analyzed with short time Fourier transforms in heart sound processing program by graphical user interface. The user is able to select a band pass of signal for filter and choose the power spectrum of heart sound for display. The output database from this prototype is necessary for Medical Education or Clinical Practice. The prototype was tested and it worked satisfactory.


Author(s):  
K.L. More ◽  
R.A. Lowden ◽  
T.M. Besmann

Silicon nitride possesses an attractive combination of thermo-mechanical properties which makes it a strong candidate material for many structural ceramic applications. Unfortunately, many of the conventional processing techniques used to produce Si3N4, such as hot-pressing, sintering, and hot-isostatic pressing, utilize significant amounts of densification aids (Y2O3, Al2O3, MgO, etc.) which ultimately lowers the utilization temperature to well below that of pure Si3N4 and also decreases the oxidation resistance. Chemical vapor deposition (CVD) is an alternative processing method for producing pure Si3N4. However, deposits made at temperatures less than ~1200°C are usually amorphous and at slightly higher temperatures, the deposition of crystalline material requires extremely low deposition rates (~5 μm/h). Niihara and Hirai deposited crystalline α-Si3N4 at 1400°C at a deposition rate of ~730 μm/h. Hirai and Hayashi successfully lowered the CVD temperature for the growth of crystalline Si3N4 by adding TiCl4 vapor to the SiCl4, NH3, and H2 reactants. This resulted in the growth of α-Si3N4 with small amounts of TiN at temperatures as low as 1250°C.


Author(s):  
Seok Lee ◽  
Juyong Park ◽  
Dongkyung Nam

In this article, the authors present an image processing method to reduce three-dimensional (3D) crosstalk for eye-tracking-based 3D display. Specifically, they considered 3D pixel crosstalk and offset crosstalk and applied different approaches based on its characteristics. For 3D pixel crosstalk which depends on the viewer’s relative location, they proposed output pixel value weighting scheme based on viewer’s eye position, and for offset crosstalk they subtracted luminance of crosstalk components according to the measured display crosstalk level in advance. By simulations and experiments using the 3D display prototypes, the authors evaluated the effectiveness of proposed method.


Sign in / Sign up

Export Citation Format

Share Document