Three-dimensional sound-field visualization system using head mounted display and stereo camera

2016 ◽  
Vol 140 (4) ◽  
pp. 3195-3196
Author(s):  
Atsuto Inoue ◽  
Yusuke Ikeda ◽  
Kohei Yatabe ◽  
Yasuhiro Oikawa
2019 ◽  
Vol 40 (1) ◽  
pp. 1-11 ◽  
Author(s):  
Atsuto Inoue ◽  
Yusuke Ikeda ◽  
Kohei Yatabe ◽  
Yasuhiro Oikawa

2021 ◽  
Vol 263 (5) ◽  
pp. 1267-1274
Author(s):  
Atsuto Inoue ◽  
Wataru Teraoka ◽  
Yasuhiro Oikawa ◽  
Takahiro Satou ◽  
Yasuyuki Iwane ◽  
...  

There are various ways to grasp the spatial and temporal structures of sound field. Sound field visualization is an effective technique to understand spatial sound information. For example, acoustical holography, optical methods, and beam-forming have been proposed and studied. In recent years, augmented reality (AR) technology has rapidly developed and is now more familiar. Many sensors, display devices, and ICT technologies have been implemented in AR equipment, which enable interaction between real and virtual worlds. In this paper, we propose an AR display system, which displays the results obtained by the beam-forming method. The system consists of 16ch microphone array, real-time sound field visualization system and optical see-through head mounted display (OST-HMD). Real-time sound field visualization system analyses sound signals recorded by 16ch microphone array by beam-forming method. Processed sound pressures data are sent to OST-HMD by using transmission control protocol (TCP), and colormap is projected on real world. Settings property of real-time sound field visualization system can be changed by using virtual user interface (UI) and TCP. In addition, multi-users can experience the system by sharing sound pressures and settings property data. Using this system, users wearing OST-HMD can observe sound field information intuitively.


Author(s):  
F. Boehm ◽  
P. J. Schuler ◽  
R. Riepl ◽  
L. Schild ◽  
T. K. Hoffmann ◽  
...  

AbstractMicrovascular procedures require visual magnification of the surgical field, e.g. by a microscope. This can be accompanied by an unergonomic posture with musculoskeletal pain or long-term degenerative changes as the eye is bound to the ocular throughout the whole procedure. The presented study describes the advantages and drawbacks of a 3D exoscope camera system. The RoboticScope®-system (BHS Technologies®, Innsbruck, Austria) features a high-resolution 3D-camera that is placed over the surgical field and a head-mounted-display (HMD) that the camera pictures are transferred to. A motion sensor in the HMD allows for hands-free change of the exoscope position via head movements. For general evaluation of the system functions coronary artery anastomoses of ex-vivo pig hearts were performed. Second, the system was evaluated for anastomosis of a radial-forearm-free-flap in a clinical setting/in vivo. The system positioning was possible entirely hands-free using head movements. Camera control was intuitive; visualization of the operation site was adequate and independent from head or body position. Besides technical instructions of the providing company, there was no special surgical training of the surgeons or involved staff upfront performing the procedures necessary. An ergonomic assessment questionnaire showed a favorable ergonomic position in comparison to surgery with a microscope. The outcome of the operated patient was good. There were no intra- or postoperative complications. The exoscope facilitates a change of head and body position without losing focus of the operation site and an ergonomic working position. Repeated applications have to clarify if the system benefits in clinical routine.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
T Fujiwara ◽  
N Takeda ◽  
M Hatano ◽  
S Nishimura ◽  
I Komuro

Abstract Background Pulmonary hypertension (PH) is characterized by increased pulmonary vascular resistance and right heart failure with progressive narrowing or occlusion of the pulmonary artery. However, the assessment of vascular remodeling is mostly limited to averaged increases in wall thickening, and even the role of vascular endothelial growth factor (VEGF), remains incompletely understood; Although abundantly expressed VEGF is expected to elicit angio-obliteration and the knockout of hypoxia inducible factor (HIF) prevents PH in mice, VEGF inhibitor Sugen exacerbates hypoxia (Hx)-induced PH model, which is referred to as VEGF paradox. Purpose To analyze three-dimensional (3D) spatiotemporal changes of pulmonary microstructure and function, which reflect the disease activity and lead to resolve the paradox. Methods and results We developed a novel 3D visualization system of microstructural networks in whole mouse organ with single-cell resolution, using combined tissue clearing technique called CUBIC and multiphoton excitation microscope. The system enabled the simultaneous 3D evaluation of microvascular structure, invaded macrophages and fibrosis with effective penetration of several mm (whole organ). Three-dimensional observations of PH mice models including Hx, Sugen/Hx, and human-like Alk1+/− hereditary PH models, revealed that not only inward (negative) microvessel remodeling with stenosis, but also marked elongation of microvascular ECs, was evident except Sugen/Hx model at the early phase, which had not been detected by 2D histological sections. Comparable transcriptome analysis revealed that PGC1α, which regulates HIF-independent VEGF expression and angiogenesis, plays an important role in the characteristic response for mitochondrial and microvascular maintenance. PGC1α was up-regulated in the early phage in Hx and Alk1+/− PH models with microvascular angiogenetic change, whereas Sugen/Hx-model did not increase PGC1α expression and did not show microvascular remodeling. Furthermore pulmonary ECs-specific PGC1α-deficient mice exacerbated Hx-PH model with decreased VEGF expression and microvessel density, and administration of Baicalin, a flavonoid enhancing PGC1α expression, ameliorated Hx-PH model with increased VEGF expression. Conclusions The 3D visualization system disclosed an unexpected change of angiogenic microvascular structure in the early phage of PH, which is regulated by EC PGC1α. Microvascular angiogenesis which is induced by up-regulation in PGC1α -VEGF pathway is a crucial factor for compensation of PH in the early phase, which provides a potential novel therapeutic target for PH. Figure 1 Funding Acknowledgement Type of funding source: Public grant(s) – National budget only. Main funding source(s): JSJP


2011 ◽  
Vol 44 (6) ◽  
pp. 1272-1276 ◽  
Author(s):  
Koichi Momma ◽  
Fujio Izumi

VESTAis a three-dimensional visualization system for crystallographic studies and electronic state calculations. It has been upgraded to the latest version,VESTA 3, implementing new features including drawing the external morphology of crystals; superimposing multiple structural models, volumetric data and crystal faces; calculation of electron and nuclear densities from structure parameters; calculation of Patterson functions from structure parameters or volumetric data; integration of electron and nuclear densities by Voronoi tessellation; visualization of isosurfaces with multiple levels; determination of the best plane for selected atoms; an extended bond-search algorithm to enable more sophisticated searches in complex molecules and cage-like structures; undo and redo in graphical user interface operations; and significant performance improvements in rendering isosurfaces and calculating slices.


Sensors ◽  
2018 ◽  
Vol 18 (11) ◽  
pp. 3674 ◽  
Author(s):  
Wei Lu ◽  
Yu Lan ◽  
Rongzhen Guo ◽  
Qicheng Zhang ◽  
Shichang Li ◽  
...  

A spiral sound wave transducer comprised of longitudinal vibrating elements has been proposed. This transducer was made from eight uniform radial distributed longitudinal vibrating elements, which could effectively generate low frequency underwater acoustic spiral waves. We discuss the production theory of spiral sound waves, which could be synthesized by two orthogonal acoustic dipoles with a phase difference of 90 degrees. The excitation voltage distribution of the transducer for emitting a spiral sound wave and the measurement method for the transducer is given. Three-dimensional finite element modeling (FEM)of the transducer was established for simulating the vibration modes and the acoustic characteristics of the transducers. Further, we fabricated a spiral sound wave transducer based on our design and simulations. It was found that the resonance frequency of the transducer was 10.8 kHz and that the transmitting voltage resonance was 140.5 dB. The underwater sound field measurements demonstrate that our designed transducer based on the longitudinal elements could successfully generate spiral sound waves.


Sign in / Sign up

Export Citation Format

Share Document