scholarly journals Performance Characteristics of a Rapid New Immunochromatographic Test for Detection of Antibodies to Human Immunodeficiency Virus

2003 ◽  
Vol 10 (2) ◽  
pp. 303-307 ◽  
Author(s):  
Rodrigo Ribeiro-Rodrigues ◽  
Lauro Ferreira da Silva Pinto Neto ◽  
Carla B. Cunha ◽  
Valéria P. Cabral ◽  
Reynaldo Dietze

ABSTRACT A new immunochromatographic rapid test (Rapid Check HIV 1&2; Núcleo de Doenças Infecciosas) for the detection of antibodies to human immunodeficiency virus type 1 and type 2 in human samples (whole blood, serum, and plasma) was evaluated and compared to the commercially available Determine (Abbott Laboratories). When whole-blood samples were evaluated, the specificity and sensitivity of both tests were 100%. However, when plasma samples were used, sensitivity for the Rapid Check HIV 1&2 and the Determine tests were 100 and 98.58%, respectively. The observed specificity for plasma samples was 98.94% for the Rapid Check HIV 1&2 and 96.97% for the Determine test. The results presented here are encouraging and support the adoption of both tests as an alternative to enzyme-lined immunosorbent assay and/or Western blots in regions where laboratorial infrastructure is not available or for use in the management of occupational accidents for healthcare workers.

2009 ◽  
Vol 54 (2) ◽  
pp. 937-939 ◽  
Author(s):  
Caroline Barau ◽  
Constance Delaugerre ◽  
Joséphine Braun ◽  
Nathalie de Castro ◽  
Valérie Furlan ◽  
...  

ABSTRACT Raltegravir concentrations and human immunodeficiency virus type 1 (HIV-1) RNA levels in semen samples from 10 treatment-experienced HIV-1-infected patients were measured after 24 weeks of raltegravir-based highly active antiretroviral therapy (HAART). Semen and plasma HIV-1 RNA levels were below 100 copies/ml and 50 copies/ml, respectively, in all samples. The median raltegravir concentrations in semen samples (n = 10) and in plasma samples (n = 9) drawn simultaneously were 345 (range, 83 to 707) ng/ml and 206 (range, 106 to 986) ng/ml, respectively. The median semen-to-plasma ratio of raltegravir concentration was 1.42 (range, 0.52 to 6.66), indicating good although variable levels of drug penetration of raltegravir in the seminal compartment.


2000 ◽  
Vol 38 (12) ◽  
pp. 4637-4639 ◽  
Author(s):  
Yi-Wei Tang ◽  
Joe T.-J. Huong ◽  
Robert M. Lloyd ◽  
Paul Spearman ◽  
David W. Haas

The source of human immunodeficiency virus type 1 (HIV-1) RNA in cerebrospinal fluid (CSF) during HIV-1 infection is uncertain. The sequence heterogeneity of HIV-1 RNA in simultaneous CSF and plasma samples was characterized for five patients at the baseline and during the first week of antiretroviral therapy by two commercial genotyping methodologies. In individual subjects, the sequences in CSF samples differed significantly from those in plasma. In contrast, the viral sequences in CSF at the baseline did not differ from the sequences in CSF during treatment. Similarly, viral sequences in plasma did not vary over this interval. This study provides evidence that HIV-1 RNA in CSF and plasma arise from distinct compartments.


2000 ◽  
Vol 7 (4) ◽  
pp. 698-699 ◽  
Author(s):  
Susan Phillips ◽  
Timothy C. Granade ◽  
Chou-Pong Pau ◽  
Debra Candal ◽  
Dale J. Hu ◽  
...  

ABSTRACT We evaluated six rapid tests for their sensitivity and specificity in diagnosing human immunodeficiency virus type 1 (HIV-1) infection using 241 specimens (172 HIV-1 positive, 69 HIV-1 negative) representing different HIV-1 subtypes (A [n = 40], B [n = 47], C [n = 28], E [n = 42], and F [n = 7]). HIVCHEK, Multispot, RTD and SeroStrip were 100% sensitive and specific. Capillus failed to identify two of eight subtype C specimens (overall sensitivity of 98.85%), while the SUDS test (the only test approved by the Food and Drug Administration) gave false-positive results for 5 of 69 seronegative specimens (specificity of 93.24%). Our results suggest that although rapid tests perform well in general, it may be prudent to evaluate a rapid test for sensitivity and specificity in a local population prior to its widespread use.


2009 ◽  
Vol 83 (23) ◽  
pp. 12336-12344 ◽  
Author(s):  
Linda L. Dunn ◽  
Mary Jane McWilliams ◽  
Kalyan Das ◽  
Eddy Arnold ◽  
Stephen H. Hughes

ABSTRACT Although human immunodeficiency virus type 1 (HIV-1) reverse transcriptase (RT) has been extensively studied, there are still significant questions about the effects of mutations on the maturation and stability of RT. We show here that a significant fraction (>80%) of the single point mutations we generated in the thumb subdomain of HIV-1 (RT) affect the stability of RT in virions. Fragments of the unstable mutant RTs can be detected in Western blots of virion proteins; however, the degree of degradation varies. The titers of the mutants whose virions contain degraded RTs are reduced. Some, but not all, of the unstable RT thumb subdomain mutants we analyzed have a temperature-sensitive phenotype. A preliminary survey of mutations in other subdomains of RT shows that some of these mutations also destabilize RT. The stability of the RT mutants is enhanced by the addition of a protease inhibitor, suggesting that the viral protease plays an important role in the degradation of the mutant RTs. These results confirm and extend earlier reports of mutations that affect the stability of RT in virions. The data suggest that the stability of a mutant RT in virions could be a major factor in determining the virus titer and, by extension, viral fitness, which could affect whether a mutation in RT is acceptable to the virus.


2006 ◽  
Vol 80 (6) ◽  
pp. 3030-3041 ◽  
Author(s):  
Eloisa Yuste ◽  
Hannah B. Sanford ◽  
Jill Carmody ◽  
Jacqueline Bixby ◽  
Susan Little ◽  
...  

ABSTRACT To date, only a small number of anti-human immunodeficiency virus type 1 (HIV-1) monoclonal antibodies (MAbs) with relatively broad neutralizing activity have been isolated from infected individuals. Adequate techniques for defining how frequently antibodies of these specificities arise in HIV-infected people have been lacking, although it is generally assumed that such antibodies are rare. In order to create an epitope-specific neutralization assay, we introduced well-characterized HIV-1 epitopes into the heterologous context of simian immunodeficiency virus (SIV). Specifically, epitope recognition sequences for the 2F5, 4E10, and 447-52D anti-HIV-1 neutralizing monoclonal antibodies were introduced into the corresponding regions of SIVmac239 by site-directed mutagenesis. Variants with 2F5 or 4E10 recognition sequences in gp41 retained replication competence and were used for neutralization assays. The parental SIVmac239 and the neutralization-sensitive SIVmac316 were not neutralized by the 2F5 and 4E10 MAbs, nor were they neutralized significantly by any of the 96 HIV-1-positive human plasma samples that were tested. The SIV239-2F5 and SIV239-4E10 variants were specifically neutralized by the 2F5 and 4E10 MAbs, respectively, at concentrations within the range of what has been reported previously for HIV-1 primary isolates (J. M. Binley et al., J. Virol. 78:13232-13252, 2004). The SIV239-2F5 and SIV239-4E10 epitope-engrafted variants were used as biological screens for the presence of neutralizing activity of these specificities. None of the 92 HIV-1-positive human plasma samples that were tested exhibited significant neutralization of SIV239-2F5. One plasma sample exhibited >90% neutralization of SIV239-4E10, but this activity was not competed by a 4E10 target peptide and was not present in concentrated immunoglobulin G (IgG) or IgA fractions. We thus confirm by direct analysis that neutralizing activities of the 2F5 and 4E10 specificities are either rare among HIV-1-positive individuals or, if present, represent only a very small fraction of the total neutralizing activity in any given plasma sample. We further conclude that the structures of gp41 from SIVmac239 and HIV-1 are sufficiently similar such that epitopes engrafted into SIVmac239 can be readily recognized by the cognate anti-HIV-1 monoclonal antibodies.


1998 ◽  
Vol 5 (1) ◽  
pp. 41-44 ◽  
Author(s):  
Sharon Shalekoff ◽  
Caroline T. Tiemessen ◽  
Clive M. Gray ◽  
Desmond J. Martin

ABSTRACT Phagocytosis and oxidative burst in whole-blood granulocytes were assessed by flow cytometry with Phagotest and Bursttest kits, respectively. Seventy individuals were included in this study: 15 healthy, normal donors, 18 human immunodeficiency virus (HIV) type 1 (HIV-1)-seropositive patients, 19 patients with pulmonary tuberculosis (TB), and 18 patients co-infected with Mycobacterium tuberculosis and HIV-1 (TB-HIV). Granulocyte phagocytosis was assessed by incubating whole blood with fluorescence-labelledEscherichia coli and measuring the proportion of granulocytes with ingested bacteria and the capacity (fluorescence intensity) of each cell to phagocytose E. coli. The percentage of granulocytes converting nonfluorescent dihydrorhodamine to fluorescent rhodamine 123 on production of reactive oxygen intermediates (ROIs) and the mean channel shift were assessed as a measure of oxidative burst. No differences in the proportion of granulocytes that were capable of phagocytosing or producing ROIs in response to E. coli were observed between any of the study groups. Phagocytosis was significantly enhanced in granulocytes from HIV-1-infected individuals. On the other hand, granulocytes from individuals infected with M. tuberculosis alone or in combination with HIV-1 had a significantly reduced capacity to phagocytose E. coli and to produce ROIs in response toE. coli as an agonist. These results provide evidence that granulocytes from individuals with pulmonary TB with or without concomitant infection with HIV-1 have an impaired ability to phagocytose and to undergo oxidative burst, possibly contributing to the enhanced susceptibility to opportunistic infections in these patients.


1998 ◽  
Vol 36 (9) ◽  
pp. 2495-2498 ◽  
Author(s):  
John N. Nkengasong ◽  
Mirielle Kalou ◽  
Chantal Maurice ◽  
Celestin Bile ◽  
Marie-Yolande Borget ◽  
...  

We compared the sensitivity and accuracy of the NucliSens assay and those of both the standard and modified (addition of a new primer set, primer mix 1, supplied by Roche) Amplicor HIV Monitor assays to quantify human immunodeficiency virus type 1 (HIV-1) RNA in persons infected with HIV-1 subtype A in Abidjan, Côte d’Ivoire. Seventy-one plasma samples from HIV-1-seropositive persons at different stages of HIV infection and 15 samples from HIV antibody-negative persons were analyzed. The HIV-1 genetic subtype was determined either by DNA sequencing or by a restriction fragment length polymorphism assay. Of the 71 samples, 70 (98%) were subtype A and 1 was subtype G. Of the 70 subtype A samples, the proportion of RNA-positive plasma samples and mean HIV-1 RNA levels were significantly higher by the modified HIV Monitor assay (n = 67 [96%]; mean RNA levels, 5.2 log10 HIV-1 RNA copies/ml) than the NucliSens assay (n = 56 [80%]; 4.3 log10 HIV-1 RNA copies/ml) or the standard HIV Monitor assay (n = 44 [63%]; mean RNA levels, 3.8 log10 HIV-1 RNA copies/ml) (all P values were <0.05). The HIV-1 RNA levels by the modified HIV Monitor assay correlated significantly with those by the NucliSens assay (r = 0.76; P< 0.001) and the standard HIV Monitor assay (r = 0.57; P < 0.001), as did the RNA levels by the NucliSens and the standard HIV Monitor assays (r = 0.60; P < 0.001). Lower CD4 cell counts were significantly correlated with higher HIV-1 RNA levels by all three assays (r = −0.47 for the NucliSens assay, −0.45 for the standard HIV Monitor assay, and −0.62 for the modified HIV Monitor assay). These results indicate that the modified HIV Monitor assay has the highest sensitivity and efficiency at quantifying the levels of RNA in persons infected with HIV-1 subtype A and thus constitutes a valuable tool for the monitoring of RNA levels in areas of Africa were HIV-1 subtype A is predominant.


2001 ◽  
Vol 75 (11) ◽  
pp. 5421-5424 ◽  
Author(s):  
Renaud Burrer ◽  
Dominique Salmon-Ceron ◽  
Sophie Richert ◽  
Gianfranco Pancino ◽  
Gabriella Spiridon ◽  
...  

ABSTRACT The factors present in serum and plasma samples of human immunodeficiency virus (HIV)-infected patients that are responsible for the neutralization of four HIV type 1 (HIV-1) primary isolates in vitro have been analyzed. Purification of immunoglobulins (Ig) by affinity chromatography showed that the activities were mostly attributable to IgG and less frequently to IgA. For two samples, we have shown that the high-level and broad-spectrum inhibitory activity was essentially caused by non-Ig factors interfering with the measurement of antibody-specific neutralizing activity.


1998 ◽  
Vol 36 (12) ◽  
pp. 3657-3661 ◽  
Author(s):  
Ana S. Vallari ◽  
Robert K. Hickman ◽  
John R. Hackett ◽  
Catherine A. Brennan ◽  
Vincent A. Varitek ◽  
...  

A rapid immunodiagnostic test that detects and discriminates human immunodeficiency virus (HIV) infections on the basis of viral type, HIV type 1 (HIV-1) group M, HIV-1 group O, or HIV-2, was developed. The rapid assay for the detection of HIV (HIV rapid assay) was designed as an instrument-free chromatographic immunoassay that detects immunoglobulin G (IgG) antibodies to HIV. To assess the performance of the HIV rapid assay, 470 HIV-positive plasma samples were tested by PCR and/or Western blotting to confirm the genotype of the infecting virus. These samples were infected with strains that represented a wide variety of HIV strains including HIV-1 group M (subtypes A through G), HIV-1 group O, and HIV-2 (subtypes A and B). The results showed that the HIV genotype identity established by the rapid assay reliably (469 of 470 samples) correlates with the HIV genotype identity established by PCR or Western blotting. A total of 879 plasma samples were tested for IgG to HIV by a licensed enzyme immunoassay (EIA) (470 HIV-positive samples and 409 HIV-negative samples). When they were tested by the rapid assay, 469 samples were positive and 410 were negative (99.88% agreement). Twelve seroconversion panels were tested by both the rapid assay and a licensed EIA. For nine panels identical results were obtained by the two assays. For the remaining three panels, the rapid assay was positive one bleed later in comparison to the bleed at which the EIA was positive. One hundred three urine samples, including 93 urine samples from HIV-seropositive individuals and 10 urine samples from seronegative individuals, were tested by the rapid assay. Ninety-one of the ninety-three urine samples from HIV-seropositive individuals were found to be positive by the rapid assay. There were no false-positive results (98.05% agreement). Virus in all urine samples tested were typed as HIV-1 group M. These results suggest that a rapid assay based on the detection of IgG specific for selected transmembrane HIV antigens provides a simple and reliable test that is capable of distinguishing HIV infections on the basis of viral type.


Sign in / Sign up

Export Citation Format

Share Document