scholarly journals The diagnostic accuracy of B-mode ultrasound in detecting meniscal tears: a systematic review and pooled meta-analysis

2018 ◽  
Vol 20 (2) ◽  
pp. 164 ◽  
Author(s):  
Fajin Dong ◽  
Lei Zhang ◽  
Shuxia Wang ◽  
Duo Dong ◽  
Jinfeng Xu ◽  
...  

Aim: To evaluate the diagnostic accuracy of meniscal tears using B-mode ultrasound and high-frequency linear probe by conducting a systematic review and pooled meta-analysis. Material and methods: The Cochrane library, Embase, and Pubmed were searched for relevant studies up to 29 July 2017. The arthroscopy was used as the reference standard. The results were estimated by pooled sensitivity, specificity, diagnostic odds ratio, likelihood ratio, and the area under the summary receiver operating characteristic (SROC). Results: Seven prospective studies met the selection criteria, comprising 321meniscal tears from 472 patients. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and area under the SROC curve were 88.80% (95%CI: 82.83-92.87), 84.66% (95%CI: 75.89-90.64), 5.79(95%CI: 3.66-9.15), 0.13 (95%CI: 0.09-0.20), and 43.74 (95%CI: 24.01-79.68), respectively. The area under the SROC curve was 93% (95%CI: 91-95). Conclusions: This meta-analysis indicates that 2-dimensional ultrasound is useful, and could be routinely used for estimating meniscal injuries in the human knee joint

2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Qi Ni ◽  
Chaoqian Li ◽  
Hua Lin

Objectives. The mortality rate of patients with acute respiratory distress syndrome (ARDS) is high. Hence, it is crucial to identify a reliable biomarker with wide clinical applications for predicting the prognosis of patients with ARDS. This systematic review and meta-analysis was conducted to investigate the value of plasma N-terminal probrain natriuretic peptide (NT-proBNP) for predicting mortality in patients with ARDS. Methods. An electronic search of databases including PubMed, Web of Science, Cochrane Library, and Chinese National Knowledge Infrastructure was conducted up to May 31, 2019, without language restrictions. The quality of the included studies was evaluated using QUADAS-2. Data were extracted and analyzed to obtain pooled estimates of sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio. A forest graph was used to evaluate heterogeneity. Potential causes of heterogeneity were further explored by subgroup analysis based on the testing day, testing method, observation endpoint, or cut-off points. A summary receiver operating characteristic curve was drawn to obtain the pooled area under the curve. Results. A total of 7 studies involving 581 patients with ARDS were included. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were as follows: 0.79 (95% CI: 0.72–0.84), 0.79 (95% CI: 0.66–0.88), 3.68 (95% CI: 2.16–6.28), 0.27 (95% CI: 0.20–0.38), and 13.58 (95% CI: 6.17–29.90), respectively. The results of subgroup analysis showed that the testing day influenced the summary sensitivity and that the cut-off points influenced the summary sensitivity and specificity. Conclusion. Our results indicate that elevated plasma NT-proBNP levels have a moderate value for predicting the mortality of patients with ARDS.


2017 ◽  
Vol 19 (1) ◽  
pp. 16 ◽  
Author(s):  
Yang Jiao ◽  
Fajin Dong ◽  
Hui Wang ◽  
Lei Zhang ◽  
Jinfeng Xu ◽  
...  

Aim: To investigate the clinical utility of shear wave elastography (SWE) imaging in the identification of malignant and benign lesions of the liver lesions by conducting a meta-analysis. Material and methods: The Cochrane library, Embase and Pubmed were searched for relevant studies with publication data through February 2016. Studies evaluating the diagnostic accuracy of SWE in the identification of malignant and benign lesions of the liver using SWE technology were selected. The cytology, histology or clinical imaging was used as the reference standard. The pooled sensitivity, specificity, diagnostic odds ratio, likelihood ratio, and the area under hierarchical summary receiver operating characteristic curve (HSROC) were used to examine the diagnostic accuracy. Results: A total of 9 cohort studies involving 1046 liver lesions (malignant 679) from 968 patients were identified. All of the 9 studies were prospective studies. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio of SWE in differentiating malignant and benign liver lesions were 82.2% (95% CI: 73.4–88.5), 80.2% (95% CI: 73.3–85.7), 4.159 (95% CI: 2.899–5.966), 0.222 (95% CI: 0.140–0.352), and 18.749 (95% CI: 8.746–40.195), respectively. The area under the HSROC curve was 87% (95% CI: 84–90). Conclusions: This meta-analysis indicates that SWE is useful in evaluating the stiffness of liver lesions and in differentiating between malignant and benign lesions. Due to the high sensitivity, specificity, and diagnostic odds ratio, SWE can be considered as a useful complement to conventional ultrasonography.


2021 ◽  
Author(s):  
Wu Chen ◽  
Kun Xu ◽  
Yiying Li ◽  
Meifang Hao ◽  
Yongsheng Yang ◽  
...  

Aims: The present study investigated and evaluated the accuracy of thoracic ultrasonography (TUS) in the diagnosis of pulmonary embolism (PE) by conducting a systematic review and meta-analysis. Material and methods: The PubMed, Em-base and the Cochrane library databases were searched till March 2019 to retrieve relevant articles and the overall diagnostic accuracy of TUS in PE diagnosis was evaluated by meta-analysis. Results: Overall, 16 studies including 1,916 patients were enrolled in this meta-analysis. Of these, 762 (39.8%) had confirmed PE. The overall sensitivity, specificity, and area under the ROC curve (AUC) of TUS for PE were 82% (95% confidence interval (CI), 72%–88%), 89% (95% CI, 79%–95%), and 0.91 (95% CI, 0.88–0.93), respectively. Other efficacy parameters assessed demonstrated a positive likelihood ratio (PLR) of (7.6; 95% CI, 4.0–14.5), negative likelihood ratio of (NLR) (0.21; 95% CI, 0.14–0.30), and diagnostic odds’ ratio (DOR) of (36.86; 95% CI, 21.41–63.48). Conclusions: The current study suggested that although TUS cannot safely rule out PE, it is likely to be used as an aid or guidance to establish procedures and help to improve the diagnostic deficits in patients with PE.


2021 ◽  
Author(s):  
Yuan Chen ◽  
Faiza Naz ◽  
Shi Fu ◽  
Mengran Shi ◽  
Haihao Li ◽  
...  

Abstract Background: In recent years, qualitative and quantitative analysis of LncRNA has been reported as a potential method for early diagnosis of bladder cancer, but the results from each research are insufficient and not completely consistent. This meta-analysis aims to evaluate the diagnostic value of LncRNA for BC.Methods: We conducted a diagnostic meta-analysis and the diagnostic significance of LncRNA in blood, urine and tumor tissues was discussed. We searched the PUBMED, EMABASE, and Cochrane Library until June 2020. The current meta-analysis was performed using Review Manager 5.2, Stata 16.0 and Meta-Disc 1.4 software. Results: A total of 18 researches involving early and/or advanced bladder cancer were finally included. The overall diagnostic accuracy was measured as follows: pooled sensitivity and specificity were 0.72 (95%CI:0.70, 0.73) and 0.76 (95%CI: 0.75, 0.78). Pooled positive likelihood ratio and negative likelihood ratio were 3.09 (95%CI: 2.66, 3.58) and 0.37 (95%CI: 0.33, 0.42). Combined diagnostic odds ratio was 9.43 (95%CI: 7.30, 12.20). A high diagnostic accuracy was demonstrated by the summary receiver operating characteristic curve, with area under the curve of 0.82 (95%CI: 0.78, 0.85). UCA1 and H19 had the best diagnostic effect, their diagnostic sensitivity and specificity were 80%, 79% and 79%, 73% respectively, the combined diagnostic odds ratio was 16.85 and 12.67 respectively.Conclusions: This meta-analysis suggests that LncRNA have great potential in the diagnosis of bladder cancer, UCA1 and H19 had the best diagnostic effect. LncRNA panel is the future development direction in the diagnosis of bladder cancer. However, larger sample researches are needed to further confirm our conclusion.


Author(s):  
Omar Ariel Espinosa ◽  
Silvana Margarida Benevides Ferreira ◽  
Fabiana Gulin Longhi Palacio ◽  
Denise da Costa Boamorte Cortela ◽  
Eliane Ignotti

IgM againstMycobacterium lepraemay be detected by enzyme-linked immunosorbent assays (ELISAs) based on phenolic glycolipid I (PGL-I) or natural disaccharide octyl bovine serum albumin (ND-O-BSA) as antigens, and the IgG response can be detected by an ELISA based on lipid droplet protein 1 (LID-1). The titers of antibodies against these antigens vary with operational classification. The aim of this study was to compare the accuracy of ELISAs involving PGL-I and ND-O-BSA with that involving LID-1. We included studies that analyze multibacillary and paucibacillary leprosy cases and evaluate the diagnostic accuracy of ELISAs based on LID-1 and/or PGL-I or ND-O-BSA as antigens to measure antibody titers againstM. leprae. Studies were found via PubMed, the Virtual Health Library Regional Portal, Literatura Latino-Americana e do Caribe em Ciências da Saúde, Índice Bibliográfico Espanhol de Ciências de Saúde, the Brazilian Society of Dermatology, National Institute for Health and Clinical Excellence, Cochrane Library, Embase (the Elsevier database), and Cumulative Index to Nursing and Allied Health Literature. The Quality Assessment of Diagnostic Accuracy Studies served as a methodological validity tool. Quantitative data were extracted using the Standards for Reporting of Diagnostic Accuracy. Sensitivity, specificity, and a diagnostic odds ratio were calculated, and a hierarchical summary receiver-operating characteristic curve and forest plots were constructed. The protocol register code for this meta-analysis is PROSPERO 2017: CRD42017055983. Nineteen studies were included. ND-O-BSA showed better overall performance in terms of sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratio when compared with PGL-I and LID-1. The multibacillary group showed better performance on these parameters (than the paucibacillary group did), at 94%, 99%, 129, 0.05, and 2293, respectively. LID-1 did not provide any advantage regarding the overall estimate of sensitivity in comparison with PGL-I or ND-O-BSA.


2021 ◽  
Vol 20 ◽  
pp. 153303382110119
Author(s):  
Wen-Ting Zhang ◽  
Guo-Xun Zhang ◽  
Shuai-Shuai Gao

Background: Leukemia is a common malignant disease in the human blood system. Many researchers have proposed circulating microRNAs as biomarkers for the diagnosis of leukemia. We conducted a meta-analysis to evaluate the diagnostic accuracy of circulating miRNAs in the diagnosis of leukemia. Methods: A comprehensive literature search (updated to October 13, 2020) in PubMed, EMBASE, Web of Science, Cochrane Library, Wanfang database and China National Knowledge Infrastructure (CNKI) was performed to identify eligible studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) for diagnosing leukemia were pooled for both overall and subgroup analysis. The meta-regression and subgroup analysis were performed to explore heterogeneity and Deeks’ funnel plot was used to assess publication bias. Results: 49 studies from 22 publications with a total of 3,489 leukemia patients and 2,756 healthy controls were included in this meta-analysis. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under the curve were 0.83, 0.92, 10.8, 0.18, 59 and 0.94, respectively. Subgroup analysis shows that the microRNA clusters of plasma type could carry out a better diagnostic accuracy of leukemia patients. In addition, publication bias was not found. Conclusions: Circulating microRNAs can be used as a promising noninvasive biomarker in the early diagnosis of leukemia.


2019 ◽  
Vol 2019 ◽  
pp. 1-13 ◽  
Author(s):  
Qingqin Hao ◽  
Yadi Han ◽  
Wei Xia ◽  
Qinghui Wang ◽  
Huizhong Qian

Emerging studies have reported circRNAs were dysregulated in HCC. However, the clinical value of these circRNAs remains to be clarified. Herein, we aimed to comprehensively explore their association with the diagnosis, prognosis, and clinicopathological characteristics of HCC. PubMed, EMBASE, Web of Science, and Cochrane Library databases were comprehensively searched for eligible studies up to October 30, 2018. The diagnostic effect was evaluated by the pooled sensitivity, specificity, and other indexes. The pooled hazard ratio (HR) for overall survival (OS) and recurrence free survival (RFS) was calculated to assess the prognostic value. Ten studies on diagnosis, 12 on prognosis, and 23 on clinicopathology were identified from the databases. A total of 11 upregulated and 11 downregulated circRNAs showed an association with clinicopathological features of HCC. For the diagnosis analyses, the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) of circRNAs for HCC were 0.74 (95%CI: 0.65-0.82) and 0.76 (95%CI: 0.70-0.81), 3.1 (95%CI: 2.5-3.8), 0.34 (95%CI: 0.25-0.47), and 9 (95%CI: 6-14), respectively. The area under SROC curve (AUC) was 0.81 (95% CI: 0.78–0.84), indicating moderate diagnostic accuracy. In stratified analyses, the diagnostic performance of circRNAs varied based on the source of control and specimen type. For the prognosis analyses, increased expression of upregulated circRNAs was associated with worse OS (HR: 3.67, 95%: 2.07-6.48), while high expression of downregulated circRNAs was associated with better OS (HR: 0.38, 95%: 0.30-0.48). In conclusion, this study reveals that circRNAs may serve as promising diagnostic and prognostic biomarkers for HCC. However, further investigations are still required to explore the clinical value of circRNAs.


BMJ Open ◽  
2019 ◽  
Vol 9 (12) ◽  
pp. e033084 ◽  
Author(s):  
Jin-Rong Ni ◽  
Pei-Jing Yan ◽  
Shi-Dong Liu ◽  
Yuan Hu ◽  
Ke-Hu Yang ◽  
...  

ObjectiveTo evaluate the diagnostic accuracy of transthoracic echocardiography (TTE) in patients with pulmonary hypertension (PH).DesignSystematic review and meta-analysis.Data sources and eligibility criteriaEmbase, Cochrane Library for clinical trials, PubMed and Web of Science were used to search studies from inception to 19 June, 2019. Studies using both TTE and right heart catheterisation (RHC) to diagnose PH were included.Main resultsA total of 27 studies involving 4386 subjects were considered as eligible for analysis. TTE had a pooled sensitivity of 85%, a pooled specificity of 74%, a pooled positive likelihood ratio of 3.2, a pooled negative likelihood ratio of 0.20, a pooled diagnostic OR of 16 and finally an area under the summary receiver operating characteristic curve of 0.88. The subgroup with the shortest time interval between TTE and RHC had the best diagnostic effect, with sensitivity, specificity and area under the curve (AUC) of 88%, 90% and 0.94, respectively. TTE had lower sensitivity (81%), specificity (61%) and AUC (0.73) in the subgroup of patients with definite lung diseases. Subgroup analysis also showed that different thresholds of TTE resulted in a different diagnostic performance in the diagnosis of PH.ConclusionTTE has a clinical value in diagnosing PH, although it cannot yet replace RHC considered as the gold standard. The accuracy of TTE may be improved by shortening the time interval between TTE and RHC and by developing an appropriate threshold. TTE may not be suitable to assess pulmonary arterial pressure in patients with pulmonary diseases.PROSPERO registration numberPROSPERO CRD42019123289.


2019 ◽  
Vol 57 (6) ◽  
Author(s):  
Ali Pormohammad ◽  
Mohammad Javad Nasiri ◽  
Timothy D. McHugh ◽  
Seyed Mohammad Riahi ◽  
Nathan C. Bahr

ABSTRACTThe diagnosis of tuberculous meningitis (TBM) is difficult and poses a significant challenge to physicians worldwide. Recently, nucleic acid amplification (NAA) tests have shown promise for the diagnosis of TBM, although their performance has been variable. We undertook a systematic review and meta-analysis to evaluate the diagnostic accuracy of NAA tests with cerebrospinal fluid (CSF) samples against that of culture as the reference standard or a combined reference standard (CRS) for TBM. We searched the Embase, PubMed, Web of Science, and Cochrane Library databases for the relevant records. The QUADAS-2 tool was used to assess the quality of the studies. Diagnostic accuracy measures (i.e., sensitivity and specificity) were pooled with a random-effects model. All statistical analyses were performed with STATA (version 14 IC; Stata Corporation, College Station, TX, USA), Meta-DiSc (version 1.4 for Windows; Cochrane Colloquium, Barcelona, Spain), and RevMan (version 5.3; The Nordic Cochrane Centre, the Cochrane Collaboration, Copenhagen, Denmark) software. Sixty-three studies comprising 1,381 cases of confirmed TBM and 5,712 non-TBM controls were included in the final analysis. These 63 studies were divided into two groups comprising 71 data sets (43 in-house tests and 28 commercial tests) that used culture as the reference standard and 24 data sets (21 in-house tests and 3 commercial tests) that used a CRS. Studies which used a culture reference standard had better pooled summary estimates than studies which used CRS. The overall pooled estimates of sensitivity, specificity, positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of the NAA tests against culture were 82% (95% confidence interval [CI], 75 to 87%), 99% (95% CI, 98 to 99%), 58.6 (95% CI, 35.3 to 97.3), and 0.19 (95% CI, 0.14 to 0.25), respectively. The pooled sensitivity, specificity, PLR, and NLR of NAA tests against CRS were 68% (95% CI, 41 to 87%), 98% (95% CI, 95 to 99%), 36.5 (95% CI, 15.6 to 85.3), and 0.32 (95% CI, 0.15 to 0.70), respectively. The analysis has demonstrated that the diagnostic accuracy of NAA tests is currently insufficient for them to replace culture as a lone diagnostic test. NAA tests may be used in combination with culture due to the advantage of time to result and in scenarios where culture tests are not feasible. Further work to improve NAA tests would benefit from the availability of standardized reference standards and improvements to the methodology.


2020 ◽  
pp. 084653712090206 ◽  
Author(s):  
Waleed Abdellatif ◽  
Mahmoud Ahmed Ebada ◽  
Souad Alkanj ◽  
Ahmed Negida ◽  
Nicolas Murray ◽  
...  

Purpose: In this systematic review and meta-analysis, we aimed to investigate the accuracy of dual-energy computed tomography (DECT) in the detection of acute pulmonary embolism (PE). Methods: We searched Medline (via PubMed), EBSCO, Web of Science, Scopus, and the Cochrane Library for relevant published studies. We selected studies assessing the accuracy of DECT in the detection of PE. Quality assessment of bias and applicability was conducted using the Quality of Diagnostic Accuracy Studies-2 tool. Meta-analysis was performed to calculate mean estimates of sensitivity, specificity, positive likelihood ratio (PLR), and negative likelihood ratio (NLR). The summary receiver operating characteristic (sROC) curve was drawn to get the Cochran Q-index and the area under the curve (AUC). Results: Seven studies were included in our systematic review. Of the 182 patients included, 108 patients had PEs. The pooled analysis showed an overall sensitivity and specificity of 88.9% (95% confidence interval [CI]: 81.4%-94.1%) and 94.6% (95% CI: 86.7%-98.5%), respectively. The pooled PLR was 8.186 (95% CI: 3.726-17.986), while the pooled NLR was 0.159 (95% CI: 0.093-0.270). Cochran-Q was 0.8712, and AUC was 0.935 in the sROC curve. Conclusion: Dual-energy computed tomography shows high sensitivity, specificity, and diagnostic accuracy in the detection of acute PE. The high PLR highlights the high clinical importance of DECT as a prevalence-independent, rule-in test. Studies with a larger sample size with standardized reference tests are still needed to increase the statistical power of the study and support these findings.


Sign in / Sign up

Export Citation Format

Share Document