Heat transfer coefficients in two-dimensional Yukawa systems (numerical simulations)

2013 ◽  
Vol 116 (5) ◽  
pp. 876-885 ◽  
Author(s):  
Yu. V. Khrustalyov ◽  
O. S. Vaulina
Author(s):  
Michael Gritsch ◽  
Stefan Baldauf ◽  
Moritz Martiny ◽  
Achmed Schulz ◽  
Sigmar Wittig

The present paper reports on the use of the superposition approach in high density ratio film cooling flows. It arises from the linearity and homogeneity of the simplified boundary layer differential equations. However, it is widely assumed that the linearity does not hold for variable property flows. Therefore, theoretical considerations and numerical calculations will demonstrate the linearity of the heat transfer coefficient with the dimensionless coolant temperature θ as long as identical flow conditions are applied. This makes it necessary to perform at least two experiments at different θ but with the coolant to main flow temperature ratio kept unchanged. A comprehensive set of experiments is presented to demonstrate the capability of the superposition approach for determining heat transfer coefficients for different film cooling geometries. These comprise coolant injection from two dimensional tangential slots, single holes, and rows of cylindrical holes. Particularly, two dimensional local distributions of the heat transfer coefficient will be addressed.


1966 ◽  
Vol 88 (1) ◽  
pp. 101-107 ◽  
Author(s):  
Robert Gardon ◽  
J. Cahit Akfirat

Local as well as average heat transfer coefficients between an isothermal flat plate and impinging two-dimensional jets were measured for both single jets and arrays of jets. For a large and technologically important range of variables the results have been correlated in relatively simple terms, and their application to design is briefly considered.


2018 ◽  
Vol 130 ◽  
pp. 624-636 ◽  
Author(s):  
Sofia Korniliou ◽  
Coinneach Mackenzie-Dover ◽  
John R.E. Christy ◽  
Souad Harmand ◽  
Anthony J. Walton ◽  
...  

1972 ◽  
Vol 94 (4) ◽  
pp. 355-359 ◽  
Author(s):  
E. O. Stoffel ◽  
J. R. Welty

The effects of square and reentrant entrances on flow regimes (no “appreciable” separation, large transitory stall, and fully developed two-dimensional stall) and local heat-transfer coefficients were determined with air flowing through a symmetrical, plane-wall, two-dimensional subsonic diffuser with one of the diverging walls heated and maintained isothermal. Flow and heat-transfer studies were made for the following ranges: 2θ = 0 to 45 deg, L/W = 6 to 18, and Rextut = 4 × 104 to 3 × 105. Results indicated that 2θ, L/W, and entrance configuration greatly affected the flow regime and heat transfer. Equations relating Um′ to Ut, Ur to Ut, and equations of the type Nu = C Pr0.6Rex0.8 are presented. For the configurations tested, heat-transfer rates were greater for reentrant than for square entrances.


1982 ◽  
Vol 104 (3) ◽  
pp. 508-514 ◽  
Author(s):  
A. Mertol ◽  
R. Greif ◽  
Y. Zvirin

A study has been made of the heat transfer and fluid flow in a natural convection loop. Previous studies of these systems have utilized a one-dimensional approach which requires a priori specifications of the friction and the heat-transfer coefficients. The present work carries out a two-dimensional analysis for the first time. The results yield the friction and the heat-transfer coefficients and give their variation along the loop with the Graetz number as a parameter. Comparison is also made with experimental data for the heat flux and good agreement is obtained.


1999 ◽  
Vol 121 (1) ◽  
pp. 128-135 ◽  
Author(s):  
B. Kundu ◽  
P. K. Das

In the first part of the paper, a semi-analytical method has been described for solving the two-dimensional heat conduction equation in an eccentric annular disk fin circumscribing a circular tube, subjected to convective cooling. Analysis has been done considering both convective and insulated conditions at the fin tip. The effects of surface and tip heat transfer coefficients and eccentricity on the performance of the fin have been studied. Comparative studies have also been made between the performance of concentric and eccentric fins with same radius ratio. Next, the optimum dimensions for eccentric annular fins have been determined using Lagrange multiplier technique. In the scheme, either the fin volume or the heat transfer duty can be taken as the constraint. Finally, it has been shown that when space restriction is imposed on one side of the tube, eccentric annular fins can be designed to have lesser volumes compared to concentric annular fins above a certain heat transfer duty.


Author(s):  
Nencho Deliiski ◽  
Ladislav Dzurenda ◽  
Natalia Tumbarkova

A two-dimensional mathematical model has been created, solved, and verified for the transient nonlinear heat conduction in logs during their thawing in an air environment. For the numerical solution of the model, an explicit form of the finite-difference method in the computing medium of Visual FORTRAN Professional has been used. The chapter presents solutions of the model and its validation towards own experimental studies. During the validation of the model, the inverse task of the heat transfer has been solved for the determination of the logs’ heat transfer coefficients in radial and longitudinal directions. This task has been solved also in regard to the logs’ surface temperature, which depends on the mentioned coefficients. The results from the experimental and simulative investigation of 2D nonstationary temperature distribution in the longitudinal section of poplar logs with a diameter of 0.24 m, length of 0.48 m, and an initial temperature of approximately –30°C during their many hours thawing in an air environment at room temperature are presented, visualized, and analyzed.


Sign in / Sign up

Export Citation Format

Share Document