scholarly journals Typical within and between person variability in non-invasive ventilator derived variables among clinically stable, long-term users

2021 ◽  
Vol 8 (1) ◽  
pp. e000824
Author(s):  
Vishnu Jeganathan ◽  
Linda Rautela ◽  
Simon Conti ◽  
Krisha Saravanan ◽  
Alyssa Rigoni ◽  
...  

BackgroundDespite increasing capacity to remotely monitor non-invasive ventilation (NIV), how remote data varies from day to day and person to person is poorly described.MethodsSingle-centre, 2-month, prospective study of clinically stable adults on long-term NIV which aimed to document NIV-device variability. Participants were switched to a ventilator with tele-monitoring capabilities. Ventilation settings and masking were not altered. Raw, extensible markup language data files were provided directly from Philips Respironics (EncoreAnywhere). A nested analysis of variance was conducted on each ventilator variable to apportion the relative variation between and within participants.ResultsTwenty-nine people were recruited (four withdrew, one had insufficient data for analyses; 1364 days of data). Mean age was 54.0 years (SD 18.4), 58.3% male with body mass index of 37.0 kg/m2 (13.7). Mean adherence was 8.53 (2.23) hours/day and all participants had adherence >4 hours/day. Variance in ventilator-derived indices was predominantly driven by differences between participants; usage (61% between vs 39% within), Apnoea–Hypopnoea Index (71% vs 29%), unintentional (64% vs 36%) and total leak (83% vs 17%), tidal volume (93% vs 7%), minute ventilation (92% vs 8%), respiratory rate (92% vs 8%) and percentage of triggered breaths (93% vs 7%).InterpretationIn this clinically stable cohort, all device-derived indices were more varied between users than the day-to-day variation within individuals. We speculate that normative ranges and thresholds for clinical intervention need to be individualised, and further research is necessary to determine the clinically important relationships between clinician targets for therapy and patient-reported outcomes.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Julia García Mancebo ◽  
Sara de la Mata Navazo ◽  
Estíbaliz López-Herce Arteta ◽  
Rosario Montero Mateo ◽  
Isabel María López Esteban ◽  
...  

AbstractDuring the last decades, the number of patients with long stay admissions (LSA) in PICU has increased. The purpose of this study was to identify factors associated with PICU LSA, assessing healthcare resources use and changes in the profile of these patients. A retrospective, observational, single-center study was carried out. Characteristics of LSA were compared between two periods (2006–2010 and 2011–2015). During the earlier period there were 2,118 admissions (3.9% of them LSA), whereas during the second period, there were 1,763 (5.4% of them LSA) (p = 0.025). LSA accounted for 33.7% PICU stay days during the first period and 46.7% during the second (p < 0.001). Higher use of non-invasive ventilation (80.2% vs. 37.8%, p = 0.001) and high-flow oxygen therapy (68.8% vs. 37.8%, p = 0.005) was observed in the 2011–2015 cohort, whereas the use of arterial catheter (77.1% vs. 92.6%, p = 0.005), continuous infusion of adrenaline (55.2% vs. 75.9%, p = 0.004), and hemoderivative transfusion (74% vs. 89.2%, p = 0.010) was less frequent. In the 2006–2010 cohort, hospital-acquired infections were more common (95.2% vs. 68.8%, p < 0.001) and mortality was higher (26.8% vs. 13.8%, p = 0.026). The number of long-stay PICU admissions have increased entailing an intensive use of healthcare resources. These patients have a high risk for complications and mortality.


Thorax ◽  
2019 ◽  
Vol 74 (7) ◽  
pp. 715-717 ◽  
Author(s):  
Jesus Gonzalez-Bermejo ◽  
Jean-Paul Janssens ◽  
Claudio Rabec ◽  
Christophe Perrin ◽  
Frédéric Lofaso ◽  
...  

Episodes of patient-ventilator asynchrony (PVA) occur during acute and chronic non-invasive positive pressure ventilation (NIV). In long-term NIV, description and quantification of PVA is not standardised, thus limiting assessment of its clinical impact. The present report provides a framework for a systematic analysis of polygraphic recordings of patients under NIV for the detection and classification of PVA validated by bench testing. The algorithm described uses two different time windows: rate asynchrony and intracycle asynchrony. This approach should facilitate further studies on prevalence and clinical impact of PVA in long-term NIV.


2011 ◽  
Vol 2011 ◽  
pp. 1-5 ◽  
Author(s):  
Archit Bhatt ◽  
Arshad Majid ◽  
Anmar Razak ◽  
Mounzer Kassab ◽  
Syed Hussain ◽  
...  

Background and Purpose. Paroxysmal Atrial fibrillation/Flutter (PAF) detection rates in cryptogenic strokes have been variable. We sought to determine the percentage of patients with cryptogenic stroke who had PAF on prolonged non-invasive cardiac monitoring.Methods and Results. Sixty-two consecutive patients with stroke and TIA in a single center with a mean age of 61 (+/− 14) years were analyzed. PAF was detected in 15 (24%) patients. Only one patient reported symptoms of shortness of breath during the episode of PAF while on monitoring, and 71 (97%) of these 73 episodes were asymptomatic. A regression analysis revealed that the presence of PVCs (ventricular premature beats) lasting more than 2 minutes (OR 6.3, 95% CI, 1.11–18.92;P=.042) and strokes (high signal on Diffusion Weighted Imaging) (OR 4.3, 95% CI, 5–36.3;P=.041) predicted PAF. Patients with multiple DWI signals were more likely than solitary signals to have PAF (OR 11.1, 95% CI, 2.5–48.5,P<.01).Conclusion. Occult PAF is common in cryptogenic strokes, and is often asymptomatic. Our data suggests that up to one in five patients with suspected cryptogenic strokes and TIAs have PAF, especially if they have PVCs and multiple high DWI signals on MRI.


SLEEP ◽  
2017 ◽  
Vol 40 (suppl_1) ◽  
pp. A329-A329
Author(s):  
ML Castro Codesal ◽  
K Dehaan ◽  
R Featherstone ◽  
P Bedi ◽  
C Martinez Carrasco ◽  
...  

SLEEP ◽  
2017 ◽  
Vol 40 (suppl_1) ◽  
pp. A348-A349
Author(s):  
B Alkhaledi ◽  
ML Castro Codesal ◽  
D Olmstead ◽  
R Featherstone ◽  
M Sebastianski ◽  
...  

2019 ◽  
Vol 15 (2) ◽  
pp. 120-132 ◽  
Author(s):  
Cosei Valentin-Caius ◽  
Borcea Corina-Ioana ◽  
Zaharie Ana-Maria ◽  
Mihaltan Florin-Dumitru ◽  
Deleanu Oana-Claudia

The benefit of non-invasive ventilation (NIV) in stable chronic obstructive pulmonary disease (COPD) remains controversial. However, there is increasingly more evidence of NIV efficiency, especially high-flow NIV. This review presents the old and the new evidence of NIV effectiveness in stable COPD, considering pathophysiological arguments for NIV in COPD. Guidelines, randomized controlled trials (RCTs) and crossover studies included in review and metaanalysis based on patient-reported outcomes (PROs) have been analyzed. The role of NIV in rehabilitation and in palliative care and the role of telemedicine in relation with NIV are still up for debate. Challenges in choosing the right device and the optimal mode of ventilation still exist. There are also discussions on the criteria for patient inclusion and on how to meet them. More studies are needed to determine the ideal candidate for chronic NIV and to explain all the benefits of using NIV.