scholarly journals Diagnostic potential of stored dried blood spots for inborn errors of metabolism: a metabolic autopsy of medium-chain acyl-CoA dehydrogenase deficiency

2018 ◽  
Vol 71 (10) ◽  
pp. 885-889 ◽  
Author(s):  
Noriyuki Kaku ◽  
Kenji Ihara ◽  
Yuichiro Hirata ◽  
Kenji Yamada ◽  
Sooyoung Lee ◽  
...  

AimIt is estimated that 1–5% of sudden infant death syndrome (SIDS) cases might be caused by undiagnosed inborn errors of metabolism (IEMs); however, the postmortem identification of IEMs remains difficult. This study aimed to evaluate the usefulness of dried blood spots (DBSs) stored after newborn screening tests as a metabolic autopsy to determine the causes of death in infants and children who died suddenly and unexpectedly.MethodsInfants or toddlers who had suddenly died without a definite diagnosis between July 2008 and December 2012 at Kyushu University Hospital in Japan were enrolled in this study. Their Guthrie cards, which had been stored for several years at 4–8°C, were used for an acylcarnitine analysis by tandem mass spectrometry to identify inborn errors of metabolism.ResultsFifteen infants and children who died at less than 2 years of age and for whom the cause of death was unknown were enrolled for the study. After correcting the C0 and C8 values assuming the hydrolysation of acylcarnitine in the stored DBSs, the corrected C8 value of one case just exceeded the cut-off level for medium-chain acyl-CoA dehydrogenase (MCAD) deficiency screening. Genetic and biochemical analyses confirmed this patient to have MCAD deficiency.ConclusionDBSs stored after newborn screening tests are a promising tool for metabolic autopsy. The appropriate compensation of acylcarnitine data and subsequent genetic and biochemical analyses are essential for the postmortem diagnosis of inborn errors of metabolism.

Author(s):  
Mitsuhiro Haga ◽  
Mitsuhisa Isobe ◽  
Ken Kawabata ◽  
Masaki Shimizu ◽  
Hiroshi Mochizuki

Objective The acylcarnitine profile is analyzed in dried blood spots (DBS) to screen for inborn errors of metabolism. Hematocrit (Ht) is known to affect the result of quantitative analyses of DBS samples; however, the effects of Ht on the acylcarnitine profiles in DBS have not been studied in actual samples from newborns. Study Design The acylcarnitine profiles in DBS for newborn screening tests and Ht levels of very-low-birth-weight infants were obtained from medical records. We investigated the relationship between Ht and each acylcarnitine using Pearson's correlation coefficient (r). Results We examined 77 newborns in this study. There was a significantly positive correlation between Ht and C0, C2, C12, C16, C18, C18:1, and C18:1-OH, respectively (p < 0.0025). The correlation was the greatest on C2 (r = 0.59). Conclusion This study clarifies that Ht and C0, C2, C12, C16, C18, C18:1, and C18:1-OH are significantly correlated in DBS, which is consistent with previous studies. Hence, the effect of Ht should be considered when interpreting the results of acylcarnitine profiles in DBS. Key Points


2020 ◽  
Vol 10 (4(38)) ◽  
pp. 77-86
Author(s):  
Tetiana Znamenska ◽  
O. Vorobiova ◽  
I. Kuzneczov ◽  
I. Lastivka ◽  
A. Kremezna ◽  
...  

Introduction. Inborn Errors of Metabolism (IEM) are constituted a group of genetic diseases that are associated with defects in the synthesis or catabolism of complex molecules, impaired intermediary metabolism and energy production/utilization processes. The clinical manifestation of IEM is nonspecific, that looks similar to septicemia, and most often occurs in the neonatal period with life-threatening acute metabolic crises. Expanded Newborn Screening (ENS) – a biochemical study of the blood of all newborns without exception with the purpose to identify molecular markers of these diseases proved to be the most effective instrument of early IEM diagnostics. The quality of the biological samples (dried blood spots, DBS) in great extent determines the timing, accuracy, and reliability of the results of biochemical measurements. Obtaining of equivocal results in the case of analysis of poor quality DBS requires repeated laboratory tests, that delays the diagnostic process and postpones the start of specific treatment, which usually results in irreversible damage of the brain and internal organs of the child. The aim of this work is to (i) review the first results of the implementation of Expanded Newborn Screening in Ukraine (pilot part of the Baby Screen Project), and to analyze literature data regarding the negative impact of poor quality DBS on laboratory determination of IEM marker substances contents in the specimens, (ii) to characterize the typical errors in blood sampling and drying of  blood spots, and (iii) to provide practical recommendations for the proper performance of these procedures. Materials and methods. Own data of retrospective analysis of the questionable ENS results was superimposed with dried blood specimens, that were investigated in the Pharmbiotest ENS Lab to outline most common inaccuracies. Based on the comparison of these data with the relevant publications it was formulated the practical recommendations for improving quality of DBS preparation to ensure the accuracy and reliability of laboratory measurements and speed up IEM diagnostics. Results. The quality of biomaterial selection is an important part of obtaining reliable results during expanded newborn screening. Capillary blood is collected in the maternity hospital from 48-72 hours (full-term) and for 7-11 days (in preterm babies) after the birth from the heel of babies. In this case, a few drops of blood are applied to a special test card made of filter paper, which is dried and sent to the laboratory. Blood tests are performed using a highly sensitive and accurate method of chemical analysis - tandem mass spectrometry in the laboratory "Pharmbiotest", located in Ukraine. Taking into analysis the low-quality samples lead to questionable results, which requires repeated DBS sampling and re-examining. This proved to be the most common cause of delaying IEM detection, diagnosis establishment, and initiation of treatment, which can be fatal for a child with severe IEM forms. Conclusions. Informing healthcare professionals and parents about the current results of laboratory monitoring of dried blood spots quality, typical errors in blood sampling and following on-site procedures and negative consequences of its improper performance, as well as providing clear practical recommendations of how these procedures should be done is a proven way of improving and speeding up IEM diagnostics.


1997 ◽  
Vol 43 (11) ◽  
pp. 2106-2113 ◽  
Author(s):  
Donald H Chace ◽  
Steven L Hillman ◽  
Johan L K Van Hove ◽  
Edwin W Naylor

Abstract We report the application of tandem mass spectrometry to prospective newborn screening for medium-chain acyl-CoA dehydrogenase (MCAD) deficiency. MCAD deficiency is diagnosed from dried blood spots on filter paper cards from newborns on the basis of the increase of medium chain length acylcarnitines identified by isotope dilution mass spectrometry methods. A robust and accurate semiautomated method for the analysis of medium chain length acylcarnitines as their butyl esters was developed and validated. Quantitative data from the analyses of 113 randomly collected filter paper blood spots from healthy newborns showed low concentrations of medium chain length acylcarnitines such as octanoylcarnitine. The maximum concentration of octanoylcarnitine was 0.22 μmol/L, with the majority being at or below the detection limit. In all 16 blood spots from newborns with confirmed MCAD deficiency, octanoylcarnitine was highly increased [median 8.4 μmol/L (range 3.1–28.3 μmol/L)], allowing easy detection. The concentration of octanoylcarnitine was significantly higher in these 16 newborns (&lt;3 days of age) than in 16 older patients (ages 8 days to 7 years) with MCAD deficiency (median 1.57 μmol/L, range 0.33–4.4). The combined experience of prospective newborn screening in Pennsylvania and North Carolina has shown a disease frequency for MCAD deficiency of 1 in 17 706. No false-positive and no known false-negative results have been found. A validated method now exists for prospective newborn screening for MCAD deficiency.


2018 ◽  
Vol 56 (2) ◽  
pp. 278-284 ◽  
Author(s):  
Theresa Winter ◽  
Anja Lange ◽  
Anke Hannemann ◽  
Matthias Nauck ◽  
Cornelia Müller

Abstract Background: Newborn screening (NBS) is an established screening procedure in many countries worldwide, aiming at the early detection of inborn errors of metabolism. For decades, dried blood spots have been the standard specimen for NBS. The procedure of blood collection is well described and standardized and includes many critical pre-analytical steps. We examined the impact of contamination of some anticipated common substances on NBS results obtained from dry spot samples. This possible pre-analytical source of uncertainty has been poorly examined in the past. Methods: Capillary blood was obtained from 15 adult volunteers and applied to 10 screening filter papers per volunteer. Nine filter papers were contaminated without visible trace. The contaminants were baby diaper rash cream, baby wet wipes, disinfectant, liquid infant formula, liquid infant formula hypoallergenic (HA), ultrasonic gel, breast milk, feces, and urine. The differences between control and contaminated samples were evaluated for 45 NBS quantities. We estimated if the contaminations might lead to false-positive NBS results. Results: Eight of nine investigated contaminants significantly altered NBS analyte concentrations and potentially caused false-positive screening outcomes. A contamination with feces was most influential, affecting 24 of 45 tested analytes followed by liquid infant formula (HA) and urine, affecting 19 and 13 of 45 analytes, respectively. Conclusions: A contamination of filter paper samples can have a substantial effect on the NBS results. Our results underline the importance of good pre-analytical training to make the staff aware of the threat and ensure reliable screening results.


2016 ◽  
Vol 119 (1-2) ◽  
pp. 75-82 ◽  
Author(s):  
Kristi Bentler ◽  
Shaohui Zhai ◽  
Sara A. Elsbecker ◽  
Georgianne L. Arnold ◽  
Barbara K. Burton ◽  
...  

2008 ◽  
Vol 54 (3) ◽  
pp. 602-605 ◽  
Author(s):  
Ute Holtkamp ◽  
Jeanette Klein ◽  
Johannes Sander ◽  
Michael Peter ◽  
Nils Janzen ◽  
...  

Abstract Background: Blood samples for neonatal screening for inborn errors of metabolism are collected and shipped on standardized filter paper cards. Occasionally these samples are contaminated with EDTA, which is often used for anticoagulation. EDTA may interfere with newborn screening tests based on lanthanide fluorescence and thus lead to false-negative or false-positive results. Methods: We used tandem mass spectrometry (MS/MS) to detect EDTA in dried blood spots by use of an extra experiment that was integrated into the standard MS/MS neonatal screening and did not require an additional sample spot, nor extra time or work. We analyzed the influence of different blood sampling procedures on lanthanide fluorescence tests for thyroid-stimulating hormone (TSH) and 17-hydroxyprogesterone (17-OHP). Results: EDTA was increased in 138 of 190 000 newborn screening samples, 27 of which caused false- positive results in the immunoassay for 17-OHP. No false-negative TSH results were found. False-positive results in the 17-OHP test occurred when EDTA concentrations were &gt;2.0 g/L; the TSH test, however, produced false negatives only when EDTA concentrations were &gt;3.0 g/L. Using EDTA-containing devices the procedure of blood collection significantly influenced the concentration of the anticoagulant. Conclusion: Addition of EDTA quantification into standard MS/MS tests is a simple and useful method to avoid false-positive or false-negative neonatal screening results in lanthanide fluorescence–based tests.


Author(s):  
Michael J Bennett ◽  
Marie C Ragni ◽  
Robert J Ostfeld ◽  
Rene Santer ◽  
Eberhard Schmidt-Sommerfeld

We have developed methods for the measurement of the medium-chain fatty acids octanoate, decanoate and cis-4-decenoate and the acylglycines n-hexanoylglycine (HG) and 3-phenylpropionylglycine (PPG) in blood spots using gas chromatography and mass spectrometry. Normal ranges were obtained for octanoate and decanoate. HG, PPG and cis-4-decenoic acid were not detected in control blood spots. In blood spots from nine patients (including two newborn) with medium-chain acyl-CoA dehydrogenase (MCAD) deficiency, all metabolites were present in elevated concentrations although PPG was close to the detection limits and there was overlap for octanoate and decanoate. The lack of detection of cis-4-decenoic acid and HG in controls suggests that these are the metabolites of choice for blood spot identification of infants with MCAD deficiency.