scholarly journals P289 Drug product performance through inhaler life using a lama/laba combination in a dry powder inhaler

Thorax ◽  
2016 ◽  
Vol 71 (Suppl 3) ◽  
pp. A247.1-A247
Author(s):  
J Plugge ◽  
U Basaldella ◽  
B Fyrnys ◽  
T Pieper
Pharmaceutics ◽  
2021 ◽  
Vol 13 (3) ◽  
pp. 297
Author(s):  
Joana T. Pinto ◽  
Inês Cachola ◽  
João F. Pinto ◽  
Amrit Paudel

The use of physiologically based pharmacokinetic (PBPK) models to support drug product development has become increasingly popular. The in vitro characterization of the materials of the formulation provides valuable descriptors for the in silico prediction of the drug’s pharmacokinetic profile. Thus, the application of an in vitro–in silico framework can be decisive towards the prediction of the in vivo performance of a new medicine. By applying such an approach, this work aimed to derive mechanistic based insights into the potential impact of carrier particles and powder bulk properties on the in vivo performance of a lactose-based dry powder inhaler (DPI). For this, a PBPK model was developed using salbutamol sulphate (SS) as a model drug and the in vitro performance of its low-dose blends (2% w/w) with different types of lactose particles was investigated using different DPI types (capsule versus reservoir) at distinct airflows. Likewise, the influence of various carrier’s particle and bulk properties, device type and airflow were investigated in silico. Results showed that for the capsule-based device, low-dose blends of SS had a better performance, when smaller carrier particles (Dv0.5 ≈ 50 μm) with about 10% of fines were used. This resulted in a better predicted bioavailability of the drug for all the tested airflows. For the reservoir type DPI, the mean particle size (Dv0.5) was identified as the critical parameter impacting performance. Shear cell and air permeability or compressibility measurements, particle size distribution by pressure titration and the tensile strength of the selected lactose carrier powders were found useful to generate descriptors that could anticipate the potential in vivo performance of the tested DPI blends.


2021 ◽  
Vol 42 (1) ◽  
pp. 30-35 ◽  
Author(s):  
Donald P. Tashkin ◽  
Arkady Koltun ◽  
Róisín Wallace

Background: A generic combination of fluticasone propionate and salmeterol xinafoate inhalation powder in a premetered, multidose, nonreusable inhaler was recently approved. Objective: To assess the performance of the generic device. Methods: Findings from three studies with regard to device usability, function, and robustness were reviewed. Results: In a study to assess device function in patients and healthy volunteers, the generic device was successfully used by patients with asthma and chronic obstructive pulmonary disease who were either dry powder inhaler users or dry powder inhaler‐naive, even though they were not trained beyond being provided the instructions for use. In a study to measure inhaled flow rates generated by patients and healthy volunteers, the generic device consistently simulated the delivery of a full dose of drug, even to patients with severe respiratory disease and reduced inspiratory flow rates. Although the generic device had a slightly higher airflow resistance, this study demonstrated that this difference did not result in any clinically meaningful differences in terms of drug delivery. Pressure drop, a key parameter that drives the fluidization and aerosolization of the powder dose, was found to be comparable between the devices. In an open-label study, the generic device met all U.S. Food and Drug Administration specifications for device robustness after 21.5 days of twice-daily dosing via oral inhalation among 111 participants with asthma or chronic obstructive pulmonary disease. All inhalers tested demonstrated conformity with a pharmacopeia with respect to key quality parameters (assay, delivered dose uniformity, aerodynamic size distribution). There was no evidence of chemical degradation of the active ingredients, nor of microbial or water ingress into the powder, as a result of inhaler use.


Pharmaceutics ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 189
Author(s):  
Zhanying Zheng ◽  
Sharon Shui Yee Leung ◽  
Raghvendra Gupta

Dry powder inhaler (DPI) is a device used to deliver a drug in dry powder form to the lungs. A wide range of DPI products is currently available, with the choice of DPI device largely depending on the dose, dosing frequency and powder properties of formulations. Computational fluid dynamics (CFD), together with various particle motion modelling tools, such as discrete particle methods (DPM) and discrete element methods (DEM), have been increasingly used to optimise DPI design by revealing the details of flow patterns, particle trajectories, de-agglomerations and depositions within the device and the delivery paths. This review article focuses on the development of the modelling methodologies of flow and particle behaviours in DPI devices and their applications to device design in several emerging fields. Various modelling methods, including the most recent multi-scale approaches, are covered and the latest simulation studies of different devices are summarised and critically assessed. The potential and effectiveness of the modelling tools in optimising designs of emerging DPI devices are specifically discussed, such as those with the features of high-dose, pediatric patient compatibility and independency of patients’ inhalation manoeuvres. Lastly, we summarise the challenges that remain to be addressed in DPI-related fluid and particle modelling and provide our thoughts on future research direction in this field.