Fibre reinforced polymer reinforcing bars for bridge decks

2000 ◽  
Vol 27 (5) ◽  
pp. 839-849 ◽  
Author(s):  
T Hassan ◽  
A Abdelrahman ◽  
G Tadros ◽  
S Rizkalla

This paper describes the behaviour of two full-scale models of a portion of highway bridge slab reinforced with fibre reinforced polymer (FRP) reinforcement. The first slab was reinforced totally with carbon FRP (CFRP), and the second slab was reinforced with hybrid glass FRP (GFRP) and steel reinforcement. The models were tested under static loading up to failure using a concentrated load acting on each span of the continuous slab and the two cantilevers to simulate the effect of a truck wheel load. Load-deflection behaviour, crack patterns, strain distribution, and failure mode are reported. The measured values are compared to values calculated using nonlinear finite element analysis model. The accuracy of the nonlinear finite element analysis is demonstrated using independent test results conducted by others. The analytical model is used to examine the influence of various parameters, including the type of reinforcement, boundary conditions, and reinforcement ratio. Based on serviceability and ultimate capacity requirements, reinforcement ratios for using CFRP and GFRP reinforcement for typical bridge deck slabs are recommended.Key words: bridges, deflection, FRP, reinforcement, concrete, punching, slabs, shear, finite element model, strain.

2021 ◽  
Author(s):  
G. I. Zarate Garnica ◽  
Y. Yang ◽  
E. O. L. Lantsoght

<p>In the Netherlands, many existing reinforced concrete slab bridges were built more than 50 years ago. Upon assessment with the new codes, a large number of this type of bridge rate insufficiently. Since many of these existing bridges present complex material properties and boundary conditions, proof load testing is considered an effective method to assess their capacity. However, to be able to safely apply proof load testing on slab bridges, verification in the laboratory is necessary. Therefore, experiments on reinforced concrete slabs of 5 m × 2,5 m × 0,3 m under a concentrated load with varying shear span to depth ratios are carried out in the laboratory of Delft University of Technology. Additionally, nonlinear finite element analysis is used to simulate the experiments following the guidelines of nonlinear finite element analysis published by the Dutch ministry of infrastructure and water management. The results from the finite element and experimental analyses are compared in terms of peak load, failure mode, and crack pattern. A good agreement between the experimental and numerical investigations is observed.</p>


Sign in / Sign up

Export Citation Format

Share Document