TEMPERATURE-COMPENSATED FBG SENSOR FOR EXTENDED STRAIN RANGE MEASUREMENTS

Author(s):  
RICCARDO FALCIAI ◽  
COSIMO TRONO
2020 ◽  
Author(s):  
Clive Parini ◽  
Stuart Gregson ◽  
John McCormick ◽  
Daniël Janse van Rensburg ◽  
Thomas Eibert

2021 ◽  
Vol 9 (15) ◽  
pp. 9634-9643
Author(s):  
Zhenming Chu ◽  
Weicheng Jiao ◽  
Yifan Huang ◽  
Yongting Zheng ◽  
Rongguo Wang ◽  
...  

A graphene-based gradient wrinkle strain sensor with a broad range and ultra-high sensitivity was fabricated by a simple pre-stretching method. It can be applied to the detection of full-range human body motions.


2021 ◽  
Vol 11 (1) ◽  
pp. 359
Author(s):  
Sung Tae Kim ◽  
Hyejin Yoon ◽  
Young-Hwan Park ◽  
Seung-Seop Jin ◽  
Soobong Shin ◽  
...  

This paper presents a multi-functional strand capable of introducing prestressing force in prestressed concrete (PSC) girders and sensing their static and dynamic behavior as well. This innovative strand is developed by replacing the core steel wire of the strand used in PSC structures with a carbon fiber-reinforced polymer (CFRP) wire with a built-in optical Fiber Bragg Grating (FBG) sensor. A full-scale girder specimen was fabricated by applying this multi-function strand to check the possibility of tracking the change of prestressing force at each construction stage. Moreover, dynamic data could be secured during dynamic loading tests without installing accelerometers and made it possible to obtain the natural frequencies of the structure. The results verified the capability to effectively manage the prestressing force in the PSC bridge structure by applying the PC strand with a built-in optical sensor known for its outstanding practicability and durability.


2015 ◽  
Vol 08 (05) ◽  
pp. 1550018 ◽  
Author(s):  
Shupeng Liu ◽  
Na Chen ◽  
Fufei Pang ◽  
Zhengyi Chen ◽  
Tingyun Wang

Purpose: This work focused on the investigation the hyperthermia performance of the carbon-coated magnetic particles (CCMPs) in laser-induced hyperthermia. Materials and methods: We prepared CCMPs using the organic carbonization method, and then characterized them with transmission electron microscopy (TEM), ultraviolet-visible (UV-Vis) spectrophotometry, vibrating sample magnetometer (VSM) and X-ray diffraction (XRD). In order to evaluate their performance in hyperthermia, the CCMPs were tested in laser-induced thermal therapy (LITT) experiments, in which we employed a fully distributed fiber Bragg grating (FBG) sensor to profile the tissue's dynamic temperature change under laser irradiation in real time. Results: The sizes of prepared CCMPs were about several micrometers, and the LITT results show that the tissue injected with the CCMPs absorbed more laser energy, and its temperature increased faster than the contrast tissue without CCMPs. Conclusions: The CCMPs may be of great help in hyperthermia applications.


Metals ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 307
Author(s):  
Matthias Bruchhausen ◽  
Gintautas Dundulis ◽  
Alec McLennan ◽  
Sergio Arrieta ◽  
Tim Austin ◽  
...  

A substantial amount of research effort has been applied to the field of environmentally assisted fatigue (EAF) due to the requirement to account for the EAF behaviour of metals for existing and new build nuclear power plants. We present the results of the European project INcreasing Safety in NPPs by Covering Gaps in Environmental Fatigue Assessment (INCEFA-PLUS), during which the sensitivities of strain range, environment, surface roughness, mean strain and hold times, as well as their interactions on the fatigue life of austenitic steels has been characterized. The project included a test campaign, during which more than 250 fatigue tests were performed. The tests did not reveal a significant effect of mean strain or hold time on fatigue life. An empirical model describing the fatigue life as a function of strain rate, environment and surface roughness is developed. There is evidence for statistically significant interaction effects between surface roughness and the environment, as well as between surface roughness and strain range. However, their impact on fatigue life is so small that they are not practically relevant and can in most cases be neglected. Reducing the environmental impact on fatigue life by modifying the temperature or strain rate leads to an increase of the fatigue life in agreement with predictions based on NUREG/CR-6909. A limited sub-programme on the sensitivity of hold times at elevated temperature at zero force conditions and at elevated temperature did not show the beneficial effect on fatigue life found in another study.


Author(s):  
Rui Hong ◽  
Feng Wang ◽  
Yu Liu ◽  
Guojie Tu ◽  
Zhen Liu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document