A new method for determining plasma water content: application in pseudohyponatremia

2007 ◽  
Vol 292 (5) ◽  
pp. F1652-F1656 ◽  
Author(s):  
Minhtri K. Nguyen ◽  
Vahram Ornekian ◽  
Anthony W. Butch ◽  
Ira Kurtz

Pseudohyponatremia is a clinical condition characterized by an increased fraction of protein or lipid in plasma, thereby resulting in an artificially low plasma sodium concentration ([Na+]p). Since the automated method of measuring [Na+]pin most laboratories involves the use of an indirect ion-selective electrode (I-ISE), this method does not correct for elevated protein or lipid concentrations. In I-ISE, the plasma sample is diluted before the actual measurement is obtained, and the [Na+]pis determined based on the assumption that plasma is normally composed of 93% plasma water. Therefore, the [Na+]pas determined by I-ISE will be artificially low in clinical conditions when the plasma water content (PWC) is <93%. In contrast, the plasma is not diluted when the [Na+]pis measured using direct ISE (D-ISE). This method directly measures Na+activity in plasma water and is therefore unaffected by the proportion of plasma occupied by water. In this study, we report a novel quantitative method for determining the PWC utilizing I-ISE and D-ISE. To validate this new method experimentally, we altered the PWC in vitro by dissolving varying amount of salt-free albumin in human plasma. We then measured PWC gravimetrically in each sample and compared the gravimetrically determined PWC with the ISE-determined PWC. Our findings indicate that the PWC can be accurately determined based on differences in the [Na+]pas measured by I-ISE and D-ISE and that this new quantitative method can be a useful adjunct in the analysis of the dysnatremias.

1958 ◽  
Vol 36 (3) ◽  
pp. 333-338 ◽  
Author(s):  
F. A. Sréter ◽  
Sydney M. Friedman

After running a distance of 100 meters in 7 minutes, untrained rats showed a rise in plasma potassium and a fall in plasma sodium as measured in tail vein samples. These changes are in accord with in vitro observations of the effects of exercise on isolated muscle preparations and similarly are taken to indicate a gain of sodium and a loss of potassium by the exercised muscles in the whole animal. Within 10 minutes of completion of the exercise, plasma sodium concentration was restored to normal while potassium was restored within 20 minutes. Exercise was accompanied by a fall in haematocrit, which remained low for up to 40 minutes. A period of 2 months of preliminary training modified the response to exercise. In these trained animals, a fall in sodium concentration occurred as before but the rise in potassium concentration was less in degree and the haematocrit did not change. It is suggested that the rate of increase of plasma potassium is an index of muscle efficiency while the height of plasma potassium is correlated with the fatigue limit of exercise.


2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Tanya Bozhkova ◽  
Nina Musurlieva ◽  
Diyan Slavchev

Introduction. The wide variety of methods for recording occlusal contacts and the contradictory data on the interpretation of the obtained markings provoked us to make a comparative laboratory study between different occlusal indicators. Purpose. Evaluation of a qualitative and quantitative method for registration of occlusal contacts in static occlusion in laboratory conditions. Materials and Methods. In completion of the objective, we designed an apparatus for registration of the occlusal contacts (AROC) in static occlusion which is used, corresponding to the MIP in clinical conditions. The occlusal indicators that were included in the study were articulating paper 100 μ, articulating foil 12 μ, and T-Scan Novus system with a sensor thickness of 100 μ. The collected primary statistical information was entered and processed with the statistical package SPSS Statistics 19.0, and the graphs were prepared using Microsoft Office 2019. We performed descriptive statistical analysis in this study. Comparisons were performed using one-way analysis of variance (ANOVA), Student’s t -test, and Pearson coefficient method. For a significance level, p < 0.05 was chosen. Result and Discussion. With quality occlusal indicators, it is possible only to visually determine the size, number, and intensity of the marked contacts. After the statistical processing of the obtained data on the number of registered contacts, a significant difference is found in the number of contacts of certain teeth (18, 24, 25, 28, 38, 35, 34, 33, 44, 45, and 48) registered with articulating paper and articulating foil. The maximum force that is reported during the study with the T-Scan system is 93.72% and the forces in the right half of the dentition are 51.7% and in the left 48.9%. To visualize the location of the registered occlusal contacts with the system, it is intraoral to use a quality indicator and we recommend the use of articulating foil. Conclusion. Based on findings from the current in vitro simulation, we can conclude that the type of occlusal indicator influences the registration of contacts, and therefore, we propose as a method of choice to achieve a balanced occlusion in clinical practice to combine the use of one conventional and one quantitative method.


1958 ◽  
Vol 36 (1) ◽  
pp. 333-338
Author(s):  
F. A. Sréter ◽  
Sydney M. Friedman

After running a distance of 100 meters in 7 minutes, untrained rats showed a rise in plasma potassium and a fall in plasma sodium as measured in tail vein samples. These changes are in accord with in vitro observations of the effects of exercise on isolated muscle preparations and similarly are taken to indicate a gain of sodium and a loss of potassium by the exercised muscles in the whole animal. Within 10 minutes of completion of the exercise, plasma sodium concentration was restored to normal while potassium was restored within 20 minutes. Exercise was accompanied by a fall in haematocrit, which remained low for up to 40 minutes. A period of 2 months of preliminary training modified the response to exercise. In these trained animals, a fall in sodium concentration occurred as before but the rise in potassium concentration was less in degree and the haematocrit did not change. It is suggested that the rate of increase of plasma potassium is an index of muscle efficiency while the height of plasma potassium is correlated with the fatigue limit of exercise.


2014 ◽  
pp. 83-89
Author(s):  
Dung Ngo ◽  
Thi Nhan Nguyen ◽  
Khanh Hoang

Objective: Study on 106 patients with closed head injury, assessment of serum ADH concentration, correlation with Glasgow score, sodium and plasma osmotic pressure. Patients and methods: Patients with closed head injuries were diagnosed determined by computerized tomography, admitted to the Hue Central Hospital 72 hours ago. Results: (i) Serum concentration of ADH 42.21 ± 47.80 pg/ml. (ii) There is a negative correlation between serum levels of ADH with: (1) Glasgow point r = -0.323, p <0.01; (2) Plasma sodium concentration r = - 0.211, p > 0.05; (3) Plasma osmotic pressure r = - 0.218, p> 0.05. Conclusion: There is a negative correlation between serum levels of ADH with Glasgow scale, plasma sodium concentration and osmotic pressure in plasma. Key words: ADH traumatic brain injury.


Nephron ◽  
2021 ◽  
pp. 1-3
Author(s):  
Rosa D. Wouda ◽  
Rik H.G. Olde Engberink ◽  
Eliane F.E. Wenstedt ◽  
Jetta J. Oppelaar ◽  
Liffert Vogt

Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 2162
Author(s):  
Mohammad Mamouei ◽  
Subhasri Chatterjee ◽  
Meysam Razban ◽  
Meha Qassem ◽  
Panayiotis A. Kyriacou

Dermal water content is an important biophysical parameter in preserving skin integrity and preventing skin damage. Traditional electrical-based and open-chamber evaporimeters have several well-known limitations. In particular, such devices are costly, sizeable, and only provide arbitrary outputs. They also do not permit continuous and non-invasive monitoring of dermal water content, which can be beneficial for various consumer, clinical, and cosmetic purposes. We report here on the design and development of a digital multi-wavelength optical sensor that performs continuous and non-invasive measurement of dermal water content. In silico investigation on porcine skin was carried out using the Monte Carlo modeling strategy to evaluate the feasibility and characterize the sensor. Subsequently, an in vitro experiment was carried out to evaluate the performance of the sensor and benchmark its accuracy against a high-end, broad band spectrophotometer. Reference measurements were made against gravimetric analysis. The results demonstrate that the developed sensor can deliver accurate, continuous, and non-invasive measurement of skin hydration through measurement of dermal water content. Remarkably, the novel design of the sensor exceeded the performance of the high-end spectrophotometer due to the important denoising effects of temporal averaging. The authors believe, in addition to wellbeing and skin health monitoring, the designed sensor can particularly facilitate disease management in patients presenting diabetes mellitus, hypothyroidism, malnutrition, and atopic dermatitis.


2021 ◽  
Vol 13 (6) ◽  
pp. 796-800
Author(s):  
Ting Zhao ◽  
Zhanbo Hu ◽  
Xin-Sheng Chai ◽  
Yukai Zheng ◽  
Binxin Xu ◽  
...  

This paper reports a new method for the determination of sludge water content by a multiple headspace extraction gas chromatographic (MHE-GC) method. It is based on the water vapor signals in the sample vial from the first five extractions.